    30 Products

    Fire-Stop Caulk

    Image of ProductInUse. Front orientation. Fire Stops. Fire-Stop Caulk, Caulk.
    Image of ProductInUse. Front orientation. Fire Stops. Fire-Stop Caulk, Spray-On Caulk.

    Caulk

    Spray-On Caulk

    Image of Product. Cartridge. Front orientation. Fire Stops. Fire-Stop Caulk, Caulk, Cartridge.
    Image of Product. Pail. Front orientation. Fire Stops. Fire-Stop Caulk, Caulk, Pail.
    Image of Product. Stick. Front orientation. Fire Stops. Fire-Stop Caulk, Caulk, Stick.

    Cartridge

    Pail

    Stick

    Easy to apply and quick to set, this caulk is a popular choice for sealing small openings in fire-resistant walls and floors. It’s often used to line seams or fill gaps around cables or pipes that run between rooms. You can use it alone or with other fire-stop products. It resists vibration, so it will flex with movement rather than crack or pull away from surfaces. Apply with a caulk gun or trowel.
    Spray On—Spray-on caulk is used to evenly coat hard-to-reach openings. It’s often used to seal the spaces where fire-rated walls, floors, and ceilings meet.
    Acrylic Plastic—Acrylic plastic caulk is water-based, which is the most common formula for fire-stop caulk. It’s a good choice for most applications.
    Silicone Rubber—Silicone rubber caulk forms a watertight, flexible seal. Use it to seal openings that are exposed to weather, washdowns, or standing water.
    Expandable—Expandable caulk is used to seal the area around PVC pipes, cables, and other equipment that can melt or shrink during a fire. When it’s heated, it expands to fill gaps.
    Flammability Rating—This caulk is tested to ASTM and UL standards for stopping the spread of smoke and flames.
    Container
    Size
    Type
    Application
    Temp., ° F
    Color
    Fire Safety
    Rating
    Flammability Rating
    Specs. Met
    Certification
    Each
    Caulk
     
    Acrylic Plastic
    10.3 fl. oz.Cartridge40 to 120Red4 hr.ASTM E84 10/0 for Flame and Smoke, ASTM E119, ASTM E1966, UL 263, UL 723 10/0 for Flame and Smoke, UL 1479, UL 2079ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    9339K33000000
    30 fl. oz.Cartridge40 to 120Red4 hr.ASTM E84 10/0 for Flame and Smoke, ASTM E119, ASTM E1966, UL 263, UL 723 10/0 for Flame and Smoke, UL 1479, UL 2079ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    9339K3400000
     
    Acrylic Plastic—Expandable
    10.3 fl. oz.Cartridge40 to 120Red4 hr.ASTM E84 0/0 for Flame and Smoke, ASTM E119, ASTM E1966, UL 263, UL 723 0/0 for Flame and Smoke, UL 1479, UL 2079ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    93465K1100000
    30 fl. oz.Cartridge40 to 120Red4 hr.ASTM E84 0/0 for Flame and Smoke, ASTM E119, ASTM E1966, UL 263, UL 723 0/0 for Flame and Smoke, UL 1479, UL 2079ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    93465K1200000
    5 gal.Pail40 to 120Red4 hr.ASTM E84 0/0 for Flame and Smoke, ASTM E119, ASTM E1966, UL 263, UL 723 0/0 for Flame and Smoke, UL 1479, UL 2079ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    93465K14000000
     
    Silicone Rubber—Watertight
    10.1 fl. oz.Cartridge-20 to 120Gray3 hr.ASTM E84 3/22 for Flame and Smoke, ASTM E119, ASTM E1966, UL 263, UL 723 3/22 for Flame and Smoke, UL 1479, UL 2079ASTM C920, ASTM E90, ASTM E814, ASTM E1399, ULC-S101, ULC-S102, ULC-S115FM Approved
    93455K5100000
    20.2 fl. oz.Stick-20 to 120Gray3 hr.ASTM E84 3/22 for Flame and Smoke, ASTM E119, ASTM E1966, UL 263, UL 723 3/22 for Flame and Smoke, UL 1479, UL 2079ASTM C920, ASTM E90, ASTM E814, ASTM E1399, ULC-S101, ULC-S102, ULC-S115FM Approved
    93455K5500000
     
    Spray-On Caulk
     
    Acrylic Plastic
    5 gal.Pail40 to 120Red3 hr.ASTM E84 0/0 for Flame and Smoke, ASTM E119, ASTM E1966, UL 263, UL 723 0/0 for Flame and Smoke, UL 1479, UL 2079ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    93455K56000000
     

    Fire-Stop Putty

    Image of ProductInUse. Front orientation. Fire Stops. Fire-Stop Putty.
    Image of Product. Pad. Front orientation. Fire Stops. Fire-Stop Putty, Pads.

    Pad

    Image of Product. Stick. Front orientation. Fire Stops. Fire-Stop Putty, Sticks.

    Stick

    Hand-mold this putty into small openings in fire-resistant walls and floors.
    Pads—Putty pads are often used to seal the area around electrical boxes. Mold them onto the sides of the box before installing it in a wall or floor.
    Expandable—Often used to seal the area around PVC pipes or cables, it expands when heated to fill the gaps left if your equipment melts.
    Flammability Rating—This putty is tested to ASTM and UL standards to stop the spread of smoke and flames.
    Each
    Package
    Form
    Lg.
    Wd.
    Thk.
    Color
    Application
    Temp., ° F
    Fire-Stop
    Application
    Fire Safety
    Rating
    Flammability Rating
    Specs. Met
    Certification
    Performance
    Each
    Pkg.
    Qty.
    Pkg.
    Pad7"7"1/8"Red40 to 120Through Penetration3 hr.ASTM E84 10/125 for Flame and Smoke, ASTM E119, UL 263, UL 723 10/125 for Flame and Smoke, UL 1479ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated9340K2200000209340K240000000
    Stick10"1 1/2"1 1/2"Red40 to 120Through Penetration3 hr.ASTM E84 10/125 for Flame and Smoke, ASTM E119, UL 263, UL 723 10/125 for Flame and Smoke, UL 1479ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated9340K2300000129340K25000000
     

    Fire-Stop Electrical Box Inserts

    Seal electrical boxes to maintain fire-resistant walls. These inserts mount inside electrical boxes to block the spread of smoke and flames. They fit common box sizes.
    Gaskets
    Image of ProductInUse. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Gaskets.
    Image of Product. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Gaskets, For NEMA Outlets.
    Image of Product. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Gaskets, For GFCI Outlets.
    Image of Product. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Gaskets, For Toggle Switches.

    For

    NEMA

    Outlets

    For

    GFCI

    Outlets

    For

    Toggle

    Switches

    Use gaskets when cable or switches have already been installed. They sit just inside your cover plate.
    Expandable—When heated, they expand to seal gaps, such as those left by melted wire.
    Each
    Package
    Outlet Box
    Designation
    For No.
    of Outlets
    For No. of Toggle
    Switches
    Lg.
    Wd.
    Thk.
    Application
    Temp., ° F
    Fire-Stop
    Application
    Fire Safety
    Rating
    Flammability Rating
    Specs. Met
    Certification
    Performance
    Each
    Pkg.
    Qty.
    Pkg.
    For NEMA Outlets
    1 Gang
    25"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N11100000508505N1120000000
    2 Gang
    45"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N1130000508505N114000000
     
    For GFCI Outlets
    1 Gang
    15"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N1150000508505N116000000
    2 Gang
    25"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N1170000508505N118000000
     
    For Toggle Switches
    1 Gang
    15"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N1190000508505N121000000
    2 Gang
    25"5"1/8"40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N1220000508505N123000000
     
    Pads
    Image of ProductInUse. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Pads.
    Image of Product. Front orientation. Fire Stops. Fire-Stop Electrical Box Inserts, Pads.
    Use pads before cable is installed. The adhesive side sticks to the back wall of your electrical box. They can be used only with metallic boxes.
    Expandable—When heated, they expand to seal gaps, such as those left by melted wire.
    Each
    Package
    Outlet Box
    Designation
    Lg.
    Wd.
    Thk.
    Mount Type
    Application
    Temp., ° F
    Fire-Stop
    Application
    Fire Safety
    Rating
    Flammability Rating
    Specs. Met
    Certification
    Performance
    Each
    Pkg.
    Qty.
    Pkg.
    1 Gang
    1 13/16"2 13/16"1/4"Adhesive Back40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N12400000508505N1250000000
    2 Gang
    3 3/4"3 11/16"1/4"Adhesive Back40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N1260000508505N127000000
    2 Gang
    4 3/8"4 3/8"1/4"Adhesive Back40 to 120Through Penetration2 hr.ASTM E84 5/5 for Flame and Smoke, ASTM E119, UL 263, UL 723 5/5 for Flame and Smoke, UL 1479ASTM E90, ASTM E814, ASTM G21, ULC-S101, ULC-S102, ULC-S115FM Approved
    Expandable, Fire Rated8505N12800000508505N129000000
     