Insertion-Mount Flow Switches
For Pipe Size | Flow Set Point Range, gpm | Max. Flow Rate, gpm | Paddle Material | Max. Pressure @ Temp. | Temp. Range, ° F | Max. Switching Current @ Voltage | Body Ht. | Enclosure Rating | Certification | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Brass Body with 1 NPT Male Threaded Brass Fittings | |||||||||||||
Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles | |||||||||||||
| 1 2 4 6 | 4.9 to 17.6 13.7 to 56.4 35.3 to 118 60.3 to 245 | 27, 105, 397, 900 | 304 Stainless Steel | 160 psi @ 70° F | 33 to 225 | 3.7 amp @ 240V AC 7.4 amp @ 120V AC | 5" | NEMA 4X | C-UL Listed UL Recognized Component | 4971K5 | 0000000 | ||
| 1 2 4 6 | 6 to 10.2 18.8 to 32.8 39.7 to 73.5 79.2 to 166 | 27, 105, 397, 900 | 304 Stainless Steel | 160 psi @ 70° F | 33 to 300 | 3.7 amp @ 240V AC 7.4 amp @ 120V AC | 5" | — | C-UL Listed UL Listed | 4971K3 | 000000 | ||
316 Stainless Steel Body with 1 NPT Male Threaded 316 Stainless Steel Fittings | |||||||||||||
Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles | |||||||||||||
| 1 2 4 6 | 6 to 10.2 18.8 to 32.8 39.7 to 73.5 79.2 to 166 | 27, 105, 397, 900 | 304 Stainless Steel | 160 psi @ 70° F | 33 to 300 | 3.7 amp @ 240V AC 7.4 amp @ 120V AC | 5" | — | C-UL Listed UL Listed | 4971K4 | 000000 | ||
Electronic Flow Switches
Pipe Connections | Flow Set Point, gpm | Max. Pressure @ Temp. | Temp. Range, ° F | Voltage, V DC | Max. Switching Current @ Voltage | End-to-End Lg. | Enclosure Rating | Certification | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Aluminum/Brass/Plastic Body with Threaded Nickel-Plated Brass Fittings | ||||||||||||
1 PNP Signal Output | ||||||||||||
| 3/4 NPT Female | 0.26 to 6.6 | 360 psi @ 70° F | 32 to 185 | 30 | 100 mA @ 30V DC | 3" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4546N11 | 0000000 | ||
| 1 NPT Female | 1.32 to 26.4 | 360 psi @ 70° F | 32 to 185 | 30 | 100 mA @ 30V DC | 3 5/8" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4546N12 | 000000 | ||
Electronic Insertion-Mount Flow Switches
Flow Set Point | 1 13/16" Probe Length | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Pipe Size | For Liquids, gpm | For Gas, scfm | Max. Pressure @ Temp. | Temp. Range, ° F | Voltage, V DC | Max. Switching Current @ Voltage | Body Ht. | Enclosure Rating | Certification | Each | |||
304 Stainless Steel Body with 316 Stainless Steel Fittings | |||||||||||||
1 Digital NPN Signal Output | |||||||||||||
| 1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4,300 psi @ 70° F | -10 to 175 | 36 | 250 mA @ 19V DC 250 mA @ 36V DC | 2 11/16" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4547N13 | 0000000 | ||
1 Digital PNP Signal Output | |||||||||||||
| 1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4,300 psi @ 70° F | -10 to 175 | 36 | 250 mA @ 36V DC 250 mA @ 18V DC | 2 11/16" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4547N11 | 000000 | ||
2 Digital NPN Signal Output | |||||||||||||
| 1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4,300 psi @ 70° F | -10 to 175 | 36 | 250 mA @ 19V DC 250 mA @ 36V DC | 2 11/16" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4547N14 | 000000 | ||
2 Digital PNP Signal Output | |||||||||||||
| 1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4,300 psi @ 70° F | -10 to 175 | 36 | 250 mA @ 36V DC 250 mA @ 18V DC | 2 11/16" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4547N12 | 000000 | ||
Airflow-Actuated HVAC Switches
Paddle | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Speed Set Point, fpm | Temp. Range, ° F | Current @ Voltage | Electrical Connection | Switch Designation | For Conduit Trade Size | Knockout Dia. | Material | Ht. | Wd. | For Use Outdoors | Enclosure Rating | Certification | Each | |||
Paddle Sensors | ||||||||||||||||
| 350 to 500 | 32 to 104 | 10 amp @ 240V AC 16 amp @ 120V AC | Screw Terminal | SPDT | 1/2 | 7/8" | Stainless Steel | 6 7/8" | 3 1/8" | Yes | IP43, NEMA 3R | UL Listed, C-UL Listed, CE Marked | 1783K13 | 0000000 | ||
Flow and Temperature Transmitters
Flow Measurement Type | Pipe Connections | Flow Range, gph | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Seal Material | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch Output—4-Pole M12 Connection Plug | |||||||||||||||
316 Stainless Steel Body with 316 Stainless Steel Fitting | |||||||||||||||
| Variable Area | 3/4 NPT Female | 5 to 240 | 5 9/16" | ±5% | 580 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N11 | 0000000 | ||
| Variable Area | 3/4 NPT Female | 7 to 360 | 5 9/16" | ±5% | 580 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N12 | 000000 | ||
| Variable Area | 3/4 NPT Female | 10 to 600 | 5 9/16" | ±5% | 580 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N13 | 000000 | ||
| Variable Area | 1 NPT Female | 30 to 1,620 | 5 3/4" | ±5% | 362 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N14 | 000000 | ||
| Variable Area | 1 1/2 NPT Female | 60 to 3,000 | 6 3/16" | ±5% | 362 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N15 | 000000 | ||
Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs | |||||||||||||||
316 Stainless Steel Body with 316 Stainless Steel Fitting | |||||||||||||||
| Vortex | 1/2 NPT Female | 16 to 317 | 4 11/16" | ±2% | 172 psi @ 70° F | 14 to 190 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4401N16 | 000000 | ||
| Vortex | 1/2 NPT Female | 32 to 634 | 4 11/16" | ±2% | 172 psi @ 70° F | 14 to 190 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4401N17 | 000000 | ||
| Vortex | 3/4 NPT Female | 80 to 1,585 | 5 15/32" | ±2% | 172 psi @ 70° F | 14 to 190 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4401N18 | 000000 | ||
Sanitary Electronic Insertion-Mount Flow Switches
Flow Set Point | 13/16" Probe Length | 1 13/16" Probe Length | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | For Liquids, gpm | For Gas, scfm | Max. Pressure @ Temp. | Temp. Range, ° F | Voltage, V DC | Max. Switching Current @ Voltage | Body Ht. | Enclosure Rating | Certification | Food Industry Std. | Each | Each | ||||
316 Stainless Steel Body with 316 Stainless Steel Fittings | ||||||||||||||||
1 Digital PNP Signal Output | ||||||||||||||||
| 1 1/2" 2" | 0.55 to 54.21 0.97 to 96.37 | 4.84 to 72.47 8.59 to 128.84 | 430 psi @ 70° F | -10 to 200 | 36 | 250 mA @ 19V DC 250 mA @ 36V DC | 3 5/16" | IP67, IP69K | C-UL Listed UL Listed CE Marked | 3-A Certified 74-07, FDA Compliant 21 CFR 177.2415 | 4548N11 | 0000000 | 4548N12 | 0000000 | ||
High-Accuracy Flow and Temperature Transmitters
![]() |
Flow Range | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Measurement Type | Pipe Connections | Gallons per Minute, gpm | Liters per Minute, L/min | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs | |||||||||||||||
316 Stainless Steel/Plastic/Polybutylene Body with 316 Stainless Steel Fitting | |||||||||||||||
| Magnetic Induction | 1/2 NPT Female | 0.03 to 6.6 | 0.1 to 25 | 2 1/8" | ±2% | 225 psi @ 70° F | 0 to 175 | 20 to 30 | Any Angle | No | IP67 | 4397N101 | 0000000 | ||
| Magnetic Induction | 3/4 NPT Female | 0.02 to 13.22 | 0.2 to 50 | 2 1/8" | ±2% | 225 psi @ 70° F | 0 to 175 | 20 to 30 | Any Angle | No | IP67 | 4397N102 | 000000 | ||
| Magnetic Induction | 1 NPT Female | 0.1 to 26.4 | 0.2 to 100 | 2 1/8" | ±2% | 225 psi @ 70° F | 0 to 175 | 20 to 30 | Any Angle | No | IP67 | 4397N103 | 000000 | ||
| Magnetic Induction | 1 1/2 NPT Female | 1.3 to 79.3 | 5 to 300 | 6 11/16" | ±0.8% | 225 psi @ 70° F | 0 to 175 | 20 to 30 | Any Angle | No | IP65, IP67 | 4397N104 | 00000000 | ||
| Magnetic Induction | 2 NPT Female | 1.3 to 158.5 | 5 to 600 | 7 1/16" | ±0.8% | 225 psi @ 70° F | 0 to 175 | 20 to 30 | Any Angle | No | IP65, IP67 | 4397N105 | 00000000 | ||
Flow, Pressure, and Temperature Transmitters for Gases
![]() |
Flow Measurement Type | Pipe Connections | Flow Range, scfm | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Seal Material | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug | |||||||||||||||
304 Stainless Steel Body with 304 Stainless Steel Fitting | |||||||||||||||
| Thermal | 1/2 NPT Male | 0.15 to 44 | 11 13/16" | ±6% | 230 psi @ 70° F | 14 to 140 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4384N11 | 000000000 | ||
| Thermal | 1 NPT Male | 0.4 to 132 | 18 3/4" | ±6% | 230 psi @ 70° F | 14 to 140 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4384N12 | 00000000 | ||
Insertion-Mount Flow and Temperature Transmitters
Flow Measurement Type | Flow Range, gpm | Probe Lg. | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug | ||||||||||||||
316 Stainless Steel/Polybutylene Body with 316 Stainless Steel Fitting | ||||||||||||||
| Thermal | 0.02 to 12 | 3 15/16" | 7 9/16" | ±10% | 725 psi @ 212° F | 0 to 212 | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4426N101 | 0000000 | ||
| Thermal | 0.02 to 12 | 7 7/8" | 11 1/2" | ±10% | 725 psi @ 212° F | 0 to 212 | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4426N102 | 000000 | ||
Flow Transmitters
Flow Measurement Type | Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Seal Material | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One 4-20 mA Analog Transmitter Output—4-Pole M12 Connection Plug | |||||||||||||||
316L Stainless Steel/Aluminum/Brass/Plastic Body with 316 Stainless Steel/Brass Fitting | |||||||||||||||
| Variable Area | 1 NPT Female | 0.5 to 27 | 3 5/8" | ±5% | 362 psi @ 212° F | 14 to 212 | Fluoroelastomer | 18 to 32 | Any Angle | No | IP65, IP67 | 4386N104 | 0000000 | ||
Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs | |||||||||||||||
316L Stainless Steel/Aluminum/Brass/Plastic Body with 316 Stainless Steel/Brass Fitting | |||||||||||||||
| Variable Area | 3/4 NPT Female | 0.1 to 4 | 2 15/16" | ±5% | 580 psi @ 212° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4386N105 | 000000 | ||
| Variable Area | 3/4 NPT Female | 0.1 to 6 | 2 15/16" | ±5% | 580 psi @ 212° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4386N106 | 000000 | ||
| Variable Area | 3/4 NPT Female | 0.2 to 10 | 2 15/16" | ±5% | 580 psi @ 212° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4386N107 | 000000 | ||