    Fixed-Set-Point Flow Switches

    Image of Product. Style C. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style C.
    Image of Product. Style D. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style D.

    Style C

    Style D

    Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting position.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Straight
    Image of Product. Style C. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style C.

    Style C

    316 Stainless Steel Fitting and Bronze Fitting—Bronze and 316 stainless steel fittings resist impact better than plastic fittings.
    SPDT—SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
    Conduit
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Mounting
    Position
    Each
    Bronze Body with Bronze Fittings
     
    SPDT
    C1
    NPT
    Female0.50.075400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle000000000000000
    C1
    NPT
    Female10.15300 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 3/8"Any Angle0000000000000
    C1
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female30.45400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 3/8"Any Angle0000000000000
    C1
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female60.9400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1
    NPT
    Female81.2400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle00000000000000
    C1 1/4
    NPT
    Female10.15400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle00000000000000
    C1 1/4
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle00000000000000
    C1 1/4
    NPT
    Female203400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle00000000000000
    C1 1/2
    NPT
    Female1.50.225400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle00000000000000
    C1 1/2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle00000000000000
    C1 1/2
    NPT
    Female304.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle00000000000000
    C2
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle00000000000000
    C2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle00000000000000
    C2
    NPT
    Female507.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle00000000000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    SPDT
    C1
    NPT
    Female0.50.075400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle0000000000000000
    C1
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle0000000000000000
    C1
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle0000000000000000
    C1
    NPT
    Female60.9400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle0000000000000000
    C1
    NPT
    Female81.2400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle0000000000000000
    C2
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle0000000000000000
    C2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle0000000000000000
    C2
    NPT
    Female507.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle0000000000000000
     
    90° Elbow
    Image of Product. Style D. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style D.

    Style D

    PPS Fitting—Polypropylene and PPS fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    SPDT—SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Mounting
    Position
    Each
    PPS Body with PPS Fittings
     
    SPDT
    D1/4
    NPT
    Female0.10.02250 psi @ 70° F0 to 225400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle000000000000000
    D1/4
    NPT
    Female0.250.05250 psi @ 70° F0 to 225400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle00000000000000
    D1/4
    NPT
    Female10.2250 psi @ 70° F0 to 225400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle00000000000000
    D1/4
    NPT
    Female1.50.3250 psi @ 70° F0 to 225400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle00000000000000
     

    Flow Switches

    Activate or deactivate equipment when your flow rate reaches a set point. These switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They’re accurate in any mounting position.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Straight
    Image of Product. Front orientation. Flow Switches. Flow Switches, Straight.
    Conduit
    Pipe
    Connections
    Flow Set
    Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Each
    Bronze Body
    1 NPT Female1 to 6400 psi @ 70° F-20 to 200120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male3 1/4"00000000000000
    1 NPT Female2 to 8400 psi @ 70° F-20 to 200120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male3 1/4"0000000000000
    1 NPT Female5 to 15400 psi @ 70° F-20 to 200120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male3 1/4"0000000000000
     
    90° Elbow
    Image of Product. Front orientation. Contains Annotated. Flow Switches. Flow Switches, 90° Elbow.
    Conduit
    Pipe
    Connections
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Port-to-Port
    Lg.
    Each
    Bronze Body
    3/4 NPT Female0.75 to 4400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"00000000000000
    3/4 NPT Female2 to 8400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"0000000000000
    3/4 NPT Female7 to 14400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"0000000000000
     

    Hazardous-Location Insertion-Mount Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. Hazardous-Location Insertion-Mount Flow Switches.
    Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. They are UL listed and CSA certified for use in hazardous locations. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline. They actuate when your system’s liquid pushes the paddle into a set position. To change your set point, the paddle has multiple layers that you can remove. For the lowest set point, use the largest paddle that will fit your pipe. To increase your set point, loosen the locking washers and remove paddles. You can trim the paddles to fine-tune your set point. The smaller the paddle, the higher the setpoint.
    They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    SPDT—SPDT (singe pole, double throw) switches can turn one device from off to on (normally open) or from on to off (normally closed).
    DPDT—DPDT (double pole, double throw) switches can either turn two devices from off to on (normally open) or on to off (normally closed).
    Flow Set Point Range
    Max. Flow Rate
    Conduit
    Pipe
    Size
    Thread
    Type
    Gender
    For Pipe
    Size
    For Water and Oil
    For Air and Inert Gas
    For Water
    and Oil
    For Air and
    Inert Gas
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Body
    Ht.
    Each
    SPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"000000000000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"0000000000000000
     
    DPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"00000000000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"0000000000000000
     

    High-Pressure Flow Switches for Oil

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches for Oil.
    Measure the flow rate of oil at pressures up to 3,600 psi to activate or deactivate equipment. Designed to compensate for viscosity and density changes, these switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). Their IP65 rating protects them from dust and low-pressure washdowns, such as from a garden hose. All are accurate in any mounting position.
    These switches are calibrated with and measure oil accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Brass Body with Brass Fittings
    1/4 NPT Female0.03 to 0.12Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    00000000000000
    1/4 NPT Female0.05 to 0.3Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    1/4 NPT Female0.2 to 0.9Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    1/4 NPT Female0.5 to 2.5Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    1/2 NPT Female1.5 to 5Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    3/4 NPT Female1 to 11Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    3/4 NPT Female2 to 18Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
    1 NPT Female2 to 20Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    7 5/16"IP65
    0000000000000
     

    Air-Pressure-Actuated HVAC Switches

    Image of Product. Front orientation. HVAC Switches. Air-Pressure-Actuated HVAC Switches.
    Often used to detect clogged air filters and iced air conditioner coils, these switches sense small changes in pressure between two points in your duct.
    Pressure Set
    Point, in. H₂O
    Accuracy,
    in. H₂O
    Temp. Range,
    ° F
    Current @ Voltage
    Electrical
    Connection Type
    Switch
    Designation
    Max. Pressure,
    psi
    Low Pressure Side
    Connection
    High Pressure Side
    Inside Connection
    High Pressure Side
    Outside Connection
    For Use
    Outdoors
    Enclosure
    Rating
    Certification
    Each
    Diaphragm Sensors
    0.05 to 50.025-40 to 1652.9 amp @ 240V AC
    5.8 amp @ 120V AC
    HardwireSPDT
    11/8 NPT Female1/8 NPT Female1/2 NPSMNoNEMA 1
    CSA Certified, UL Listed
    0000000000000
    0.05 to 50.04-40 to 1654.9 amp @ 240V AC
    9.8 amp @ 120V AC
    HardwireSPDT
    11/8 NPT Female1/8 NPT Female1/2 NPSMNoNEMA 1
    CSA Certified, UL Listed
    000000000000
     

    High-Pressure Flow Switches for Gas

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches for Gas.
    Good for compressed-air systems and other compressed gases that reach up to 3,600 psi, these switches measure the flow rate to activate or deactivate equipment when they reach a set point. Tighten or loosen the adjustment screw to choose your flow rate anywhere within the set point range. As flowing gas pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
    These switches are calibrated with and measure air accurately. They can also be used with other gases by applying your gases’ specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    scfm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current
    @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Nickel-Plated Brass Body with 304 Stainless Steel Fittings
    1/4 NPT Female0.4 to 4Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 3/16"IP65
    00000000000000
    1/4 NPT Female2 to 10Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/4 NPT Female3 to 24Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/2 NPT Female4 to 30Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 3/16"IP65
    0000000000000
    3/4 NPT Female10 to 90Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 7/8"IP65
    0000000000000
    3/4 NPT Female30 to 130Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 7/8"IP65
    0000000000000
     

    High-Pressure Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches.
    Rated for pressures up to 3,600 psi, these switches measure the flow rate of liquids to activate or deactivate equipment when your flow rate reaches a set point. Tighten or loosen the adjustment screw on these switches to choose your flow rate anywhere within set point the range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current
    @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Nickel-Plated Brass Body with 304 Stainless Steel Fittings
    1/4 NPT Female0.06 to 0.8Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 3/16"IP65
    00000000000000
    1/4 NPT Female0.25 to 2.6Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/4 NPT Female0.3 to 6Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/2 NPT Female1 to 8Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 3/16"IP65
    0000000000000
    1/2 NPT Female2 to 10Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 7/8"IP65
    0000000000000
    3/4 NPT Female8 to 34Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 7/8"IP65
    0000000000000
     