Filter by
Body Material
Maximum Pressure @ Temperature
Flow Set Point
Fitting Connection
Flow Measurement Type
Environment
Shape
Fitting Material
Maximum Temperature
Set Point Configuration
Export Control Classification Number (ECCN)
U.S.–Mexico–Canada Agreement (USMCA) Qualifying
DFARS Specialty Metals
Fixed-Set-Point Flow Switches for Drinking Water
Pipe Connections | Set Point, gpm | Max. Pressure @ Temp. | Temp. Range, ° F | Voltage | Max. Switching Current @ Voltage | End-to-End Lg. | Enclosure Rating | Certification | Food Industry Std. | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Noryl Body with Threaded Brass Fittings | |||||||||||||
| 1/2 NPT Female | 0.6 | 145 psi @ 70° F | -4 to 212 | 230V AC/48V DC | 1 amp @ 230V AC 1 amp @ 48V DC | 2" | IP65 | CE Marked | NSF/ANSI 61 | 4646N11 | 0000000 | ||
Insertion-Mount Flow Switches
For Pipe Size | Flow Set Point Range, gpm | Max. Flow Rate, gpm | Paddle Material | Max. Pressure @ Temp. | Temp. Range, ° F | Max. Switching Current @ Voltage | Body Ht. | Enclosure Rating | Specs. Met | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Noryl Body with 3/4 Socket-Connect Noryl Fittings | |||||||||||||
Set-Point-Adjustment Trimmable Paddles | |||||||||||||
| 1 1/2 2 3 | 7.7 to 19.3 10.3 to 21 16.5 to 52 | 110; 150; 390 | Noryl | 160 psi @ 70° F | -13 to 212 | 1 amp @ 230V AC 1 amp @ 48V DC | 2 1/2" | IP65 | UL 508 | 2766K41 | 0000000 | ||
| 1 1/2 2 3 | 7.9 to 15 10 to 22 18 to 50 | 144; 240; 650 | 301 Stainless Steel | 160 psi @ 70° F | -13 to 212 | 1 amp @ 230V AC 1 amp @ 48V DC | 2 1/2" | IP65 | UL 508 | 2766K111 | 000000 | ||
Noryl Body with 1/2 NPT Male Threaded Brass Fittings | |||||||||||||
Set-Point-Adjustment Trimmable Paddles | |||||||||||||
| 1 1/2 2 3 4 8 | 7.7 to 19.3 10.3 to 21 16.5 to 52 25.5 to 68 126 to 240 | 110; 150; 390; 420; 1,100 | Noryl | 160 psi @ 70° F | -13 to 212 | 1 amp @ 230V AC 1 amp @ 48V DC | 2 1/2" | IP65 | UL 508 | 2766K43 | 000000 | ||
| 1 1/2 2 3 4 8 | 7.9 to 15 10 to 22 18 to 50 25 to 66 114 to 176 | 144; 240; 650; 800; 1,900 | 301 Stainless Steel | 160 psi @ 70° F | -13 to 212 | 1 amp @ 230V AC 1 amp @ 48V DC | 2 1/2" | IP65 | UL 508 | 2766K112 | 000000 | ||
Fixed-Set-Point Insertion-Mount Flow Switches
Pipe Connections | For Pipe Size | Set Point, gpm | Max. Flow Rate, gpm | Max. Pressure @ Temp. | Temp. Range, ° F | Voltage | Max. Switching Current @ Voltage | Body Ht. | Enclosure Rating | Specs. Met | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Noryl Body with Socket-Connect PVC Fittings | ||||||||||||||
| 1/2 | 1/2 | 1.03 | 7.9 | 160 psi @ 70° F | -13 to 212 | 230V AC/48V DC | 1 amp @ 230V AC 1 amp @ 48V DC | 2 1/2" | IP65 | UL 508 | 2766K113 | 0000000 | ||
| 3/4 | 3/4 | 1.94 | 21 | 160 psi @ 70° F | -13 to 212 | 230V AC/48V DC | 1 amp @ 230V AC 1 amp @ 48V DC | 2 1/2" | IP65 | UL 508 | 2766K114 | 000000 | ||
| 3/4 | 1 1 1/4 | 2.7, 6.8 | 31, 40 | 160 psi @ 70° F | -13 to 212 | 230V AC/48V DC | 1 amp @ 230V AC 1 amp @ 48V DC | 2 1/2" | IP65 | UL 508 | 2766K115 | 000000 | ||
Electronic Flow Switches
Pipe Connections | Flow Set Point, gpm | Max. Pressure @ Temp. | Temp. Range, ° F | Voltage, V DC | Max. Switching Current @ Voltage | End-to-End Lg. | Enclosure Rating | Certification | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Aluminum/Brass/Plastic Body with Threaded Nickel-Plated Brass Fittings | ||||||||||||
1 PNP Output Signal | ||||||||||||
| 3/4 NPT Female | 0.26 to 6.6 | 360 psi @ 70° F | 32 to 185 | 30 | 100 mA @ 30V DC | 3" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4546N11 | 0000000 | ||
| 1 NPT Female | 1.32 to 26.4 | 360 psi @ 70° F | 32 to 185 | 30 | 100 mA @ 30V DC | 3 5/8" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4546N12 | 000000 | ||
Electronic Insertion-Mount Flow Switches
Flow Set Point | 1 13/16" Probe Length | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Pipe Size | For Liquids, gpm | For Gas, scfm | Max. Pressure @ Temp. | Temp. Range, ° F | Voltage, V DC | Max. Switching Current @ Voltage | Body Ht. | Enclosure Rating | Certification | Each | |||
304 Stainless Steel Body with 316 Stainless Steel Fittings | |||||||||||||
1 Digital NPN Output Signal | |||||||||||||
| 1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4,300 psi @ 70° F | -10 to 175 | 36 | 250 mA @ 19V DC 250 mA @ 36V DC | 2 11/16" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4547N13 | 0000000 | ||
1 Digital PNP Output Signal | |||||||||||||
| 1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4,300 psi @ 70° F | -10 to 175 | 36 | 250 mA @ 36V DC 250 mA @ 18V DC | 2 11/16" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4547N11 | 000000 | ||
2 Digital NPN Output Signal | |||||||||||||
| 1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4,300 psi @ 70° F | -10 to 175 | 36 | 250 mA @ 19V DC 250 mA @ 36V DC | 2 11/16" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4547N14 | 000000 | ||
2 Digital PNP Output Signal | |||||||||||||
| 1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4,300 psi @ 70° F | -10 to 175 | 36 | 250 mA @ 36V DC 250 mA @ 18V DC | 2 11/16" | IP65, IP67 | C-UL Listed UL Listed CE Marked | 4547N12 | 000000 | ||
High-Pressure Flow Switches for Oil
Pipe Connections | Flow Set Point, gpm | Approx. Difference Between Set Point and Reset Point | Max. Pressure @ Temp. | Max. Temp., ° F | Max. Switching Current @ Voltage | Port-to-Port Lg. | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
SPDT | |||||||||||
Brass Body with Brass Fittings | |||||||||||
| 1/4 NPT Female | 0.03 to 0.12 | Adjustable | 3,600 psi @ 70° F | 212 | 1 amp @ 100V AC 0.42 amp @ 240V AC 1 amp @ 60V DC 0.26 amp @ 230V DC | 6 3/8" | IP65 | 4562N11 | 0000000 | ||
| 1/4 NPT Female | 0.05 to 0.3 | Adjustable | 3,600 psi @ 70° F | 212 | 1 amp @ 100V AC 0.42 amp @ 240V AC 1 amp @ 60V DC 0.26 amp @ 230V DC | 6 3/8" | IP65 | 4562N12 | 000000 | ||
| 1/4 NPT Female | 0.2 to 0.9 | Adjustable | 3,600 psi @ 70° F | 212 | 1 amp @ 100V AC 0.42 amp @ 240V AC 1 amp @ 60V DC 0.26 amp @ 230V DC | 6 3/8" | IP65 | 4562N13 | 000000 | ||
| 1/4 NPT Female | 0.5 to 2.5 | Adjustable | 3,600 psi @ 70° F | 212 | 1 amp @ 100V AC 0.42 amp @ 240V AC 1 amp @ 60V DC 0.26 amp @ 230V DC | 6 3/8" | IP65 | 4562N14 | 000000 | ||
| 1/2 NPT Female | 1.5 to 5 | Adjustable | 3,600 psi @ 70° F | 212 | 1 amp @ 100V AC 0.42 amp @ 240V AC 1 amp @ 60V DC 0.26 amp @ 230V DC | 6 3/8" | IP65 | 4562N15 | 000000 | ||
| 3/4 NPT Female | 1 to 11 | Adjustable | 3,600 psi @ 70° F | 212 | 1 amp @ 100V AC 0.42 amp @ 240V AC 1 amp @ 60V DC 0.26 amp @ 230V DC | 6 3/8" | IP65 | 4562N16 | 000000 | ||
| 3/4 NPT Female | 2 to 18 | Adjustable | 3,600 psi @ 70° F | 212 | 1 amp @ 100V AC 0.42 amp @ 240V AC 1 amp @ 60V DC 0.26 amp @ 230V DC | 6 3/8" | IP65 | 4562N17 | 000000 | ||
| 1 NPT Female | 2 to 20 | Adjustable | 3,600 psi @ 70° F | 212 | 1 amp @ 100V AC 0.42 amp @ 240V AC 1 amp @ 60V DC 0.26 amp @ 230V DC | 7 5/16" | IP65 | 4562N18 | 000000 | ||
Flow and Temperature Transmitters
Flow Measurement Type | Pipe Connections | Flow Range, gph | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Seal Material | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug | |||||||||||||||
316 Stainless Steel Body with 316 Stainless Steel Fitting | |||||||||||||||
| Variable Area | 3/4 NPT Female | 5 to 240 | 5 9/16" | ±5% | 580 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N11 | 0000000 | ||
| Variable Area | 3/4 NPT Female | 7 to 360 | 5 9/16" | ±5% | 580 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N12 | 000000 | ||
| Variable Area | 3/4 NPT Female | 10 to 600 | 5 9/16" | ±5% | 580 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N13 | 000000 | ||
| Variable Area | 1 NPT Female | 30 to 1,620 | 5 3/4" | ±5% | 362 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N14 | 000000 | ||
| Variable Area | 1 1/2 NPT Female | 60 to 3,000 | 6 3/16" | ±5% | 362 psi @ 70° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4401N15 | 000000 | ||
Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs | |||||||||||||||
316 Stainless Steel Body with 316 Stainless Steel Fitting | |||||||||||||||
| Vortex | 1/2 NPT Female | 16 to 317 | 4 11/16" | ±2% | 172 psi @ 70° F | 14 to 190 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4401N16 | 000000 | ||
| Vortex | 1/2 NPT Female | 32 to 634 | 4 11/16" | ±2% | 172 psi @ 70° F | 14 to 190 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4401N17 | 000000 | ||
| Vortex | 3/4 NPT Female | 80 to 1,585 | 5 15/32" | ±2% | 172 psi @ 70° F | 14 to 190 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4401N18 | 000000 | ||
High-Pressure Flow Switches for Gas
Pipe Connections | Flow Set Point, scfm | Approx. Difference Between Set Point and Reset Point | Max. Pressure @ Temp. | Max. Temp., ° F | Max. Switching Current @ Voltage | Port-to-Port Lg. | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
SPDT | |||||||||||
Nickel-Plated Brass Body with 304 Stainless Steel Fittings | |||||||||||
| 1/4 NPT Female | 0.4 to 4 | Adjustable | 3,600 psi @ 70° F | 212 | 0.8 amp @ 240V AC | 5 3/16" | IP65 | 4557N11 | 0000000 | ||
| 1/4 NPT Female | 2 to 10 | Adjustable | 3,600 psi @ 70° F | 212 | 0.8 amp @ 240V AC | 5 3/16" | IP65 | 4557N12 | 000000 | ||
| 1/4 NPT Female | 3 to 24 | Adjustable | 3,600 psi @ 70° F | 212 | 0.8 amp @ 240V AC | 5 3/16" | IP65 | 4557N13 | 000000 | ||
| 1/2 NPT Female | 4 to 30 | Adjustable | 3,600 psi @ 70° F | 212 | 0.8 amp @ 240V AC | 5 3/16" | IP65 | 4557N14 | 000000 | ||
| 3/4 NPT Female | 10 to 90 | Adjustable | 3,600 psi @ 70° F | 212 | 0.8 amp @ 240V AC | 5 7/8" | IP65 | 4557N15 | 000000 | ||
| 3/4 NPT Female | 30 to 130 | Adjustable | 3,600 psi @ 70° F | 212 | 0.8 amp @ 240V AC | 5 7/8" | IP65 | 4557N16 | 000000 | ||
High-Pressure Flow Switches
Pipe Connections | Flow Set Point, gpm | Approx. Difference Between Set Point and Reset Point | Max. Pressure @ Temp. | Max. Temp., ° F | Max. Switching Current @ Voltage | Port-to-Port Lg. | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
SPDT | |||||||||||
Nickel-Plated Brass Body with 304 Stainless Steel Fittings | |||||||||||
| 1/4 NPT Female | 0.06 to 0.8 | Adjustable | 3,600 psi @ 70° F | 212 | 1.5 amp @ 240V AC | 5 3/16" | IP65 | 4627N11 | 0000000 | ||
| 1/4 NPT Female | 0.25 to 2.6 | Adjustable | 3,600 psi @ 70° F | 212 | 1.5 amp @ 240V AC | 5 3/16" | IP65 | 4627N12 | 000000 | ||
| 1/4 NPT Female | 0.3 to 6 | Adjustable | 3,600 psi @ 70° F | 212 | 1.5 amp @ 240V AC | 5 3/16" | IP65 | 4627N13 | 000000 | ||
| 1/2 NPT Female | 1 to 8 | Adjustable | 3,600 psi @ 70° F | 212 | 1.5 amp @ 240V AC | 5 3/16" | IP65 | 4627N14 | 000000 | ||
| 1/2 NPT Female | 2 to 10 | Adjustable | 3,600 psi @ 70° F | 212 | 1.5 amp @ 240V AC | 5 7/8" | IP65 | 4627N15 | 000000 | ||
| 3/4 NPT Female | 8 to 34 | Adjustable | 3,600 psi @ 70° F | 212 | 1.5 amp @ 240V AC | 5 7/8" | IP65 | 4627N16 | 000000 | ||
Flow Transmitters
Flow Measurement Type | Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Seal Material | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One 4-20 mA Analog Transmitter Output—4-Pole M12 Connection Plug | |||||||||||||||
316L Stainless Steel/Aluminum/Brass/Plastic Body with 316 Stainless Steel/Brass Fitting | |||||||||||||||
| Variable Area | 1 NPT Female | 0.5 to 27 | 3 5/8" | ±5% | 362 psi @ 212° F | 14 to 212 | Fluoroelastomer | 18 to 32 | Any Angle | No | IP65, IP67 | 4386N104 | 0000000 | ||
Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs | |||||||||||||||
316L Stainless Steel/Aluminum/Brass/Plastic Body with 316 Stainless Steel/Brass Fitting | |||||||||||||||
| Variable Area | 3/4 NPT Female | 0.1 to 4 | 2 15/16" | ±5% | 580 psi @ 212° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4386N105 | 000000 | ||
| Variable Area | 3/4 NPT Female | 0.1 to 6 | 2 15/16" | ±5% | 580 psi @ 212° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4386N106 | 000000 | ||
| Variable Area | 3/4 NPT Female | 0.2 to 10 | 2 15/16" | ±5% | 580 psi @ 212° F | 14 to 212 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4386N107 | 000000 | ||
Flow, Pressure, and Temperature Transmitters for Gases
![]() |
Flow Measurement Type | Pipe Connections | Flow Range, scfm | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Seal Material | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug | |||||||||||||||
304 Stainless Steel Body with 304 Stainless Steel Fitting | |||||||||||||||
| Thermal | 1/2 NPT Male | 0.15 to 44 | 11 13/16" | ±6% | 230 psi @ 70° F | 14 to 140 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4384N11 | 000000000 | ||
| Thermal | 1 NPT Male | 0.4 to 132 | 18 3/4" | ±6% | 230 psi @ 70° F | 14 to 140 | Fluoroelastomer | 18 to 30 | Any Angle | No | IP65, IP67 | 4384N12 | 00000000 | ||
High-Accuracy Flow and Temperature Transmitters
![]() |
Flow Range | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Measurement Type | Pipe Connections | Gallons per Minute, gpm | Liters per Minute, L/min | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs | |||||||||||||||
316 Stainless Steel/Plastic/Polybutylene Body with 316 Stainless Steel Fitting | |||||||||||||||
| Magnetic Induction | 1 1/2 NPT Female | 1.3 to 79.3 | 5 to 300 | 6 11/16" | ±0.8% | 225 psi @ 70° F | 0 to 175 | 20 to 30 | Any Angle | No | IP65, IP67 | 4397N104 | 000000000 | ||
| Magnetic Induction | 2 NPT Female | 1.3 to 158.5 | 5 to 600 | 7 1/16" | ±0.8% | 225 psi @ 70° F | 0 to 175 | 20 to 30 | Any Angle | No | IP65, IP67 | 4397N105 | 00000000 | ||
Insertion-Mount Flow and Temperature Transmitters
Flow Measurement Type | Flow Range, gpm | Probe Lg. | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Input Voltage Range, V DC | Mounting Position | Field Recalibratable | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug | ||||||||||||||
316 Stainless Steel/Polybutylene Body with 316 Stainless Steel Fitting | ||||||||||||||
| Thermal | 0.02 to 12 | 3 15/16" | 7 9/16" | ±10% | 725 psi @ 212° F | 0 to 212 | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4426N101 | 0000000 | ||
| Thermal | 0.02 to 12 | 7 7/8" | 11 1/2" | ±10% | 725 psi @ 212° F | 0 to 212 | 18 to 30 | Any Angle | Yes | IP65, IP67 | 4426N102 | 000000 | ||