    Fixed-Set-Point Insertion-Mount Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Insertion-Mount Flow Switches.
    Easy to install, these flow switches come already set to a specific set point and don’t require you to disassemble your pipeline. Instead of mounting them inline, insert them into an unthreaded PVC pipe tee or pipe outlet in large-diameter pipe. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). IP rated, they seal out dust and can be lightly rinsed.
    They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle. Secure them with PVC cement and primer (not included).
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Pipe
    Connections
    For Pipe
    Size
    Set Point, gpm
    Max. Flow
    Rate, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Specs.
    Met
    Each
    Noryl Body with Socket-Connect PVC Fittings
    3/4
    3/4
    1.9421160 psi @ 70° F-13 to 212230V AC/48V DC1 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 508000000000000000
    3/4
    1
    1 1/4
    2.7, 6.831, 40160 psi @ 70° F-13 to 212230V AC/48V DC1 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 50800000000000000
     

    Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Electronic Insertion-Mount Flow Switches.
    Instead of disassembling your system for inline installation, thread these flow switches onto a mounting adapter (sold separately) and insert them into a pipe tee or pipe outlet. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. These switches are accurate in any mounting position.
    IP65 rated switches protect against dust and washdowns. IP67 rated switches withstand temporary submersion.
    Flow Set Point
    1 13/16"
    Probe Length
    For Pipe Size
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital NPN Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 19V DC
    250 mA @ 36V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    00000000000000
     
    1 Digital PNP Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 36V DC
    250 mA @ 18V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    0000000000000
     
    2 Digital NPN Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 19V DC
    250 mA @ 36V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    0000000000000
     
    2 Digital PNP Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 36V DC
    250 mA @ 18V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    0000000000000
     
    Mounting Adapters

    Insertion-Mount Flow Switches

    Image of Product. Socket Connection with IP65 Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Socket-Connect Fitting Connection, IP65 Enclosure Rating.

    Socket

    Connection

    with IP65

    Rating

    Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Noryl Body—Switches with a Noryl body have a paddle that you trim to adjust the set point. The more you trim, the higher the set point.
    Socket-Connect Fitting Connection—Socket-connect flow switches bond to an unthreaded PVC pipe tee or pipe outlet with PVC cement and primer (not included).
    Noryl Fitting—Noryl fittings work with a wide range of chemicals.
    IP65 Enclosure Rating—IP65 rated switches seal out dust and can be lightly rinsed.
    For Pipe
    Size
    Flow Set Point Range, gpm
    Max. Flow Rate, gpm
    Paddle Material
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Specs.
    Met
    Each
    Noryl Body with 3/4 Socket-Connect Noryl Fittings
     
    Set-Point-Adjustment Trimmable Paddles
    1 1/2
    2
    3
    7.7 to 19.3
    10.3 to 21
    16.5 to 52
    110, 150, 390Noryl160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 50800000000000000
    1 1/2
    2
    3
    7.9 to 15
    10 to 22
    18 to 50
    144, 240, 650301 Stainless Steel
    160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 50800000000000000
     

    Fixed-Set-Point Flow Switches

    Image of Product. Style E. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style E.

    Style E

    Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting position.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    90° Elbow
    Image of Product. Style E. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style E.

    Style E

    Polypropylene Fitting—Polypropylene and PPS fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    SPST—SPST (single pole, single throw) switches turn one device from off to on (normally open).
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Mounting
    Position
    Each
    Polypropylene Body with Polypropylene Fittings
     
    SPST
    E3/4
    NPT
    Female0.250.05100 psi @ 70° F0 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle00000000000000
    E3/4
    NPT
    Female0.50.1100 psi @ 70° F0 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle0000000000000
    E3/4
    NPT
    Female10.2100 psi @ 70° F0 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle0000000000000
     

    Electronic Flow Switches

    Image of Product. Front orientation. Flow Switches. Electronic Flow Switches.
    When these switches reach a set flow rate, they send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms. Use the adjustment screw to select their set point. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They must be mounted horizontally to function correctly. IP rated, they withstand dust, washdowns, and temporary submersion.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    Aluminum/Brass/Plastic Body with Threaded Nickel-Plated Brass Fittings
     
    1 PNP Signal Output
    3/4 NPT Female0.26 to 6.6360 psi @ 70° F32 to 18530100 mA @ 30V DC3"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    00000000000000
     

    Contactless Flow Transmitters

    Image of ProductInUse. Front orientation. Flow Transmitters. Contactless Flow Transmitters.
    Using ultrasonic waves, these transmitters measure the flow rate of your liquid from outside your pipe. They're a good choice for applications where you need to retrofit your system or avoid liquid coming into contact with the transmitter. Also known as transducers, these transmitters convert measurements to an electrical pulse that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). The pulse outputs match the input voltage of the transmitter. The higher the flow, the more pulses they send. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Configure them for either a 4-20mA or digital pulse output when installing.
    A digital display makes it easy to check flow rate and configure settings. Clamp these transmitters onto your pipe with the included mounting hardware and gel pads. They measure flow no matter the mounting orientation.
    These transmitters are calibrated with water but can be used with other liquids and will generally measure accurately, even if they differ in viscosity and density. You can recalibrate them in the field for accurate readings on pipe and operating conditions.
    Flow Range for
    Pipe Size, gpm
    Input
    Voltage
    Flow Measurement
    Type
    For Pipe
    Size
    3/4
    2
    4
    End-to-End
    Lg.
    Accuracy
    Temp. Range,
    ° F
    Min.,
    V DC
    Max.
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Pulse Output and One 4-20 mA Analog Transmitter Output—Wire Lead Connection
     
    Polycarbonate Body
    Ultrasonic3/4 to 40 to 450 to 3200 to 1,2859 3/4"±3%32 to 1851224V AC/24V DCAny AngleYesIP54
    0000000000000000
     

    Fixed-Set-Point Hazardous-Location Flow Switches

    Image of Product. Front orientation. Flow Switches. Fixed-Set-Point Hazardous-Location Flow Switches.
    Safe to use where flammable gases and combustible dust may be present, these switches activate or deactivate when your flow reaches a factory-set level. All are UL listed for hazardous environments. Because their set point is fixed, they’re ready to go, making them easy to install. They actuate when your flowing liquid or gas pushes their paddle into a set position. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function accurately.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    Set Point
    Conduit
    Pipe
    Connections
    For Liquids,
    gpm
    For Gas,
    scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with Threaded 304 Stainless Steel Fittings
    3/4 NPT Female2102,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 5/8"NEMA 4
    UL Listed
    CE Marked
    000000000000000
     
    Brass Body with Threaded Brass Fittings
    3/4 NPT Female210250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 3/8"NEMA 4
    UL Listed
    CE Marked
    00000000000000
     

    Flow Switches

    Activate or deactivate equipment when your flow rate reaches a set point. These switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They’re accurate in any mounting position.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    90° Elbow
    Image of Product. Front orientation. Contains Annotated. Flow Switches. Flow Switches, 90° Elbow.
    Conduit
    Pipe
    Connections
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Port-to-Port
    Lg.
    Each
    Bronze Body
    3/4 NPT Female0.75 to 4400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"00000000000000
    3/4 NPT Female2 to 8400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"0000000000000
    3/4 NPT Female7 to 14400 psi @ 70° F-20 to 180120/240200 mA @ 240V AC
    400 mA @ 120V AC
    1/2
    NPT
    Male1 3/8"0000000000000
     

    Flow Switches with Sight

    Image of Product. Front orientation. Flow Switches with Sight.
    For monitoring flow at a glance, these switches have a plastic window with a rotor indicator that spins when there’s flow. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. To measure flow, they count how many times the turbine turns as liquid flows through. Use them only with clean, low-viscosity liquids to prevent clogging the turbine and other damage. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
    These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    316 Stainless Steel Fitting and Brass Fitting—Brass and 316 stainless steel fittings resist impact better than polypropylene fittings.
    Any-Angle Mount—Flow switches with any-angle mounting position will measure accurately no matter how you orient them in your system.
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Mounting
    Position
    End-to-End
    Lg.
    Certification
    Each
    Brass Body with Brass Fittings
     
    3/4 NPT Female
    5 to 30200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3 15/16"CE Marked
    UL Recognized Component
    00000000000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    3/4 NPT Female
    1.5 to 15200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal5 1/4"CE Marked
    VDE Certified
    00000000000000
    5 to 30200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3 15/16"CE Marked
    UL Recognized Component
    0000000000000
    5 to 50200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal5 1/4"CE Marked
    VDE Certified
    00000000000000
     

    Variable-Pressure Flow Switches

    Image of Product. Front orientation. Flow Switches. Variable-Pressure Flow Switches.
    Accurate even in applications where pressure fluctuates regularly, these flow switches split flow into two paths and measure their difference in pressure drop to calculate the flow rate of liquid. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. They measure accurately no matter their mounting position. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). Rated NEMA 4X and IP66, they seal out dust and protect against washdowns and corrosion.
    These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage
    Max. Switching Current @ Voltage
    Conduit
    Trade Size
    End-to-End
    Lg.
    Each
    Bronze Body
     
    3/4 NPT Female
    0.5 to 6400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"000000000000000
    1.5 to 10400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"00000000000000
    2 to 15400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"00000000000000
    3 to 20400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"00000000000000
     

    Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Variable Area Flow Measurement.

    Variable Area Flow

    Measurement

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Vortex Flow Measurement.

    Vortex Flow

    Measurement

    Send flow rate and temperature measurements simultaneously to a programmable logic controller (PLC), data logger, or other receiving device. Used to monitor status or control equipment, these transmitters, also known as transducers, convert measurements to an electrical signal that is interpreted by receiving devices. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them inline with your pipe system. They’ll measure flow correctly in any mounting orientation.
    A digital display makes it easy to view readings and adjust settings at the source. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    Variable Area Flow Measurement—Variable-area transmitters determine the flow rate by tracking where the liquid pushes the piston. They have two configurable outputs. One can be wired as an analog output or a digital switch. The other one can be wired as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. These transmitters are calibrated with water, glycol solutions, and coolants but can be recalibrated in the field for other liquids.
    Vortex Flow Measurement—Vortex transmitters determine the flow rate by measuring the size of the vortex created as liquid flows through them. They don’t have any moving parts that can break or get stuck. Use them only with liquids that are at least 95% water. They have one analog output for flow and another for temperature. The output for temperature can also be wired for IO Link.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gph
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch Output—4-Pole Micro M12 Connection Plug
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Variable Area3/4 NPT Female5 to 2405 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    00000000000000
    Variable Area3/4 NPT Female7 to 3605 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    0000000000000
    Variable Area3/4 NPT Female10 to 6005 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    0000000000000
     
    Two 4-20 mA Analog Transmitter Outputs—4-Pole Micro M12 Connection Plugs
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Vortex3/4 NPT Female80 to 1,5855 15/32"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    0000000000000
     

    Flow Transmitters with Sight

    Image of Product. Front orientation. Flow Transmitters. Flow Transmitters with Sight.
    Send flow rate data using these transmitters while also being able to visually confirm liquid is flowing. They measure flow by counting how many times the turbine turns as the liquid moves through it. To prevent clogging the turbine and other damage, use them only with clean, low-viscosity liquids. These transmitters, also known as transducers, convert the flow measurement to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs), to monitor flow or control equipment. Mount them directly inline with your system. They measure accurately in any mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Analog Transmitter Output—Transmitters with an analog output increase their output signal as flow increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range.
    Digital Pulse Output—Transmitters with a digital pulse output send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Pulse Freq.,
    Hz
    Each
    One 4-20 mA Analog Transmitter Output—Wire Lead Connection
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Turbine3/4 NPT Female1.5 to 155 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo00000000000000000
    Turbine3/4 NPT Female5 to 505 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo0000000000000000
     
    One 0-5V DC Analog Transmitter Output—Wire Lead Connection
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Turbine3/4 NPT Female1.5 to 155 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo0000000000000000
    Turbine3/4 NPT Female5 to 505 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo0000000000000000
     
    One Digital Pulse Output—Wire Lead Connection
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Turbine3/4 NPT Female5 to 303 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2250000000000000
     

    High-Pressure Flow Switches for Oil

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches for Oil.
    Measure the flow rate of oil at pressures up to 3,600 psi to activate or deactivate equipment. Designed to compensate for viscosity and density changes, these switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). Their IP65 rating protects them from dust and low-pressure washdowns, such as from a garden hose. All are accurate in any mounting position.
    These switches are calibrated with and measure oil accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set
    Point, gpm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Brass Body with Brass Fittings
    3/4 NPT Female1 to 11Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    00000000000000
    3/4 NPT Female2 to 18Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    0000000000000
     

    Flow Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow Transmitters, Variable Area Flow Measurement.

    Variable Area

    Flow Measurement

    Image of Product. Back orientation. Flow Transmitters. Flow Transmitters, Turbine Flow Measurement.

    Turbine Flow

    Measurement

    Send flow rate measurements to monitor and control equipment. Also known as transducers, these transmitters convert flow rate measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure flow correctly no matter their mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Variable Area Flow Measurement—Variable-area transmitters determine flow rate by tracking where the liquid pushes an internal piston.
    Turbine Flow Measurement—Turbine transmitters measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. The digital output sends flow data with a pulse, which is a spike of voltage. The higher the flow, the more pulses they send. The voltage of the pulse output matches the input voltage sent to the transmitters. These transmitters meet NSF/ANSI 61 for use with drinking water.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Pulse Freq.,
    Hz
    Each
    One Analog Transmitter/Digital Pulse Output—Wire Lead Connection
     
    Nylon Body with Nylon Fitting
    Turbine3/4 NPT Male1.32 to 17.172 15/16"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo17 to 227000000000000000
     
    Two 4-20 mA Analog Transmitter Outputs—4-Pole Micro M12 Connection Plugs
     
    316L Stainless Steel/Aluminum/Brass/Plastic Body with 316 Stainless Steel/Brass Fitting
    Variable Area3/4 NPT Female0.1 to 42 15/16"±5%580 psi @ 212° F14 to 212Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    00000000000000
    Variable Area3/4 NPT Female0.1 to 62 15/16"±5%580 psi @ 212° F14 to 212Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    00000000000000
    Variable Area3/4 NPT Female0.2 to 102 15/16"±5%580 psi @ 212° F14 to 212Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    00000000000000
     

    High-Pressure Flow Switches for Gas

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches for Gas.
    Good for compressed-air systems and other compressed gases that reach up to 3,600 psi, these switches measure the flow rate to activate or deactivate equipment when they reach a set point. Tighten or loosen the adjustment screw to choose your flow rate anywhere within the set point range. As flowing gas pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
    These switches are calibrated with and measure air accurately. They can also be used with other gases by applying your gases’ specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    scfm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current
    @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Nickel-Plated Brass Body with 304 Stainless Steel Fittings
    3/4 NPT Female10 to 90Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 7/8"IP65
    00000000000000
    3/4 NPT Female30 to 130Adjustable3,600 psi @ 70° F2120.8 amp @ 240V AC5 7/8"IP65
    0000000000000
     

    High-Pressure Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches.
    Rated for pressures up to 3,600 psi, these switches measure the flow rate of liquids to activate or deactivate equipment when your flow rate reaches a set point. Tighten or loosen the adjustment screw on these switches to choose your flow rate anywhere within set point the range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set
    Point, gpm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current
    @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Nickel-Plated Brass Body with 304 Stainless Steel Fittings
    3/4 NPT Female8 to 34Adjustable3,600 psi @ 70° F2121.5 amp @ 240V AC5 7/8"IP65
    00000000000000
     

    High-Accuracy Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. High-Accuracy Flow and Temperature Transmitters.
    Also known as magmeters, these transmitters use a magnetic field to measure flow rate and temperature with high accuracy. Because they use a magnetic field, they only work with conductive liquids, such as water. These transmitters, also known as transducers, convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. As flow or temperature increases, the output signal increases. These transmitters have one analog output for flow and another for temperature. They only give accurate readings within the rated measurement range. A digital display makes it easy to view readings and adjust settings at the source. Mount these transmitters inline with your pipe system. They measure flow correctly in any mounting orientation.
    These transmitters are calibrated with water. They can only be used with liquids with a conductivity of at least 20 µS/cm.
    Flow Range
    Flow Measurement
    Type
    Pipe
    Connections
    Gallons per
    Minute, gpm
    Liters per
    Minute, L/min
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    Two 4-20 mA Analog Transmitter Outputs—4-Pole Micro M12 Connection Plugs
     
    316 Stainless Steel/Plastic/Polybutylene Body with 316 Stainless Steel Fitting
    Magnetic Induction3/4 NPT Female0.02 to 13.220.2 to 502 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    000000000000000
     
    back to top