Fixed-Setpoint Flow Switches
Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting orientation.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
Choose a fitting material that is compatible with the liquid you intend to run through your line. Polypropylene and PPS plastic fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
SPST (single pole, single throw) switches turn one device from off to on (normally open).
For technical drawings and 3-D models, click on a part number.

Pipe Size | Thread Type | Gender | Set Point, gpm | Approx. Difference Between Setpoint and Reset Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | End-to-End Lg. | Mounting Orientation | Each | |
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
SPST | |||||||||||
1/4 | NPT | Female | 0.1 | 0.1 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 000000 |
1/4 | NPT | Female | 0.25 | 0.25 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 00000 |
1/4 | NPT | Female | 0.5 | 0.5 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 00000 |
1/4 | NPT | Female | 0.75 | 0.75 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 00000 |
1/4 | NPT | Female | 1 | 1 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 00000 |

Pipe Size | Thread Type | Gender | Set Point, gpm | Approx. Difference Between Setpoint and Reset Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Mounting Orientation | Each | ||
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
SPST | |||||||||||
A | 1/4 | NPT | Female | 0.042 | 0.006 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 000000 |
A | 1/4 | NPT | Female | 0.1 | 0.1 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
A | 1/4 | NPT | Female | 0.25 | 0.25 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
A | 1/4 | NPT | Female | 0.5 | 0.5 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
A | 1/4 | NPT | Female | 0.75 | 0.75 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
A | 1/4 | NPT | Female | 1 | 1 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |