    118 Products

    Totalizers with Digital Display

    Image of Product. Front orientation. Flowmeters. Totalizers with Digital Display.
    A digital display makes it easy to check both the total amount of liquid that’s flowed through and the batch total. These totalizers are useful in applications where water needs to be batched and dispensed. You can reset the batch total, but you can't reset the cumulative total. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. They’re accurate in any mounting orientation. Mount them inline with your pipe system. Rated IP65, they seal out dust and can be lightly rinsed.
    These totalizers are calibrated with solvent. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from solvent.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow
    Total
    Batch
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Batteries
    Included
    Enclosure
    Rating
    Each
    Nylon Body
     
    Gallons
    1 NPT Female3 gpm to 30 gpm9,999 Gallons9,999 Gallons4"±5%150 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K750000000
     
    Liters
    1 NPT Female10 L/min to 100 L/min9,999 Liters9,999 Liters4"±5%150 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K76000000
     
    Gallons and Liters
    1 NPT Female0.3 gpm to 3 gpm999,999 Gallons
    999,999 Liters
    999,999 Gallons
    999,999 Liters
    4"±5%150 psi @ 70° F0130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K81000000
     

    Flowmeter/Totalizers

    Determine the flow rate and total volume of liquid flowing through your system with the same meter. To measure flow, these flowmeter/totalizers count how many times their turbine turns as liquid passes through. Use them only with clean, low-viscosity liquids to avoid clogging the turbine and other damage to these flowmeter/totalizers. You can reset the batch total, but you can’t reset the cumulative total. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    These flowmeter/totalizers are either calibrated with water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Choose a fitting material that is compatible with the liquid you're running through your line. IP rated, all seal out dust and can be lightly rinsed.
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVC Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, PVC Body.

    Shown with 90°

    Display Adapter Kit

    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T3110000000Digital4352K5130000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T321000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T331000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T341000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T351000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T42100000000Digital4352K1090000004352K1120000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T431000000Digital4352K513000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T441000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T451000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T461000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T471000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T49100000000Digital4352K1090000004352K112000000
     
    Accessories for Flowmeters
    Nylon Body with Nylon Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.

    Shown with 90°

    Display Adapter Kit

    Nylon fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Flowmeter/Totalizers
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K6320000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K232000000
     
    Accessories for Flowmeters
    PVDF Body with PVDF Fittings and Fluoroelastomer Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVDF Body.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVDF fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1.2 to 1280
    7 5/16"±2%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K102000000000Digital4352K51300000004352K1040000000
    1 NPT Female5 to 5080
    8 1/16"±1.5%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K10500000000Digital4352K5330000004352K107000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1.2 to 1280
    7 5/16"±2%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K10300000000Digital4352K5130000004352K104000000
     
    Accessories for Flowmeters
    316 Stainless Steel Body with 316 Stainless Steel Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, 316 Stainless Steel Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, 316 Stainless Steel Body.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Shown with 90°

    Display Adapter Kit

    Replacement Displays

    316 stainless steel fittings resist impact better than plastic fittings.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Flowmeter/Totalizers
    Replacement Displays
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Display
    Type
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1 to 104 1/4"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K5120000000Digital4352K5130000000
    3/4 NPT Female2 to 204 3/8"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K522000000Digital4352K523000000
    1 NPT Female5 to 504 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K532000000Digital4352K533000000
    1 1/2 NPT Female10 to 1005 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K54200000000Digital4352K543000000
    2 NPT Female20 to 2006 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K55200000000Digital4352K553000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1 to 104 1/4"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K85200000000Digital4352K513000000
    3/4 NPT Female2 to 204 3/8"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K86200000000Digital4352K523000000
    1 NPT Female5 to 504 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K87200000000Digital4352K533000000
    1 1/2 NPT Female10 to 1005 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K88200000000Digital4352K543000000
    2 NPT Female20 to 2006 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K89200000000Digital4352K553000000
     
    Accessories for Flowmeters

    Totalizers for Oil

    Image of Product. Front orientation. Flowmeters. Totalizers for Oil.
    Measure the amount of light oil that flows through these totalizers. They use positive displacement, so they measure flow by passing specific volumes of liquid through a chamber. Their total can be reset. Manually or automatically turn them on, and they automatically shut down 40 seconds after flow stops. Their mounting orientation won’t affect their ability to measure flow correctly. Install these totalizers directly inline with your pipe system using the fittings on each end. The fittings are 316 stainless steel, so they resist impact better than plastic fittings.
    These totalizers are calibrated with water. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Cannot Be Sold Outside North America—Products cannot be sold outside North America due to restrictions.
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Maximum Total Volume
    Displayed
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Ht.
    Wd.
    Dp.
    Display
    Type
    Batteries
    Included
    Features
    Cannot Be Sold To
    Each
    Nylon Body with 316 Stainless Steel Fittings
    1 NPT Male2 to 30999,999.9 Gallons
    999,999.9 Liters
    999,999.9 Ounces
    ±0.5%60 psi @ 70° F33130Viton® Fluoroelastomer
    Any Angle5"6"4"DigitalYesAutomatic Start and StopOutside North America41935K480000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
    1 NPT Male2 to 30999,999.9 Gallons
    999,999.9 Liters
    999,999.9 Ounces
    ±0.5%100 psi @ 70° F33185Viton® Fluoroelastomer
    Any Angle5"5"4"DigitalYesAutomatic Start and StopOutside North America41935K97000000
     

    Totalizers with Digital Display for Fuel

    Image of Product. Front orientation. Flowmeters. Totalizers with Digital Display for Fuel.
    Track batches and the total amount of gasoline, diesel fuel, and kerosene passing through your system. The batch total is resettable, but you can't reset the cumulative total. They automatically reset the batch to zero when they reach the maximum. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. They’re accurate in any mounting orientation. Mount them inline with your pipe system.
    These totalizers are calibrated with diesel fuel. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from diesel fuel.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow
    Total
    Batch
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Batteries
    Included
    Each
    Aluminum Body with Steel Fittings
    1 NPT Female3 gpm to 30 gpm9,999 Gallons9,999 Gallons4"±5%300 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYes9978K770000000
    1 NPT Female10 L/min to 100 L/min9,999 Liters9,999 Liters4"±5%300 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYes9978K78000000
     

    High-Temperature Totalizers with Digital Display

    Image of Product. Front orientation. Flowmeters. High-Temperature Totalizers with Digital Display.
    The digital display on these totalizers makes it easy to check the total amount of high-temperature liquid—up to 200° F—passing through your system. They measure flow volume by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow accurately no matter the mounting orientation. Rated NEMA 4X and IP65, they seal out dust and protect against washdowns and corrosion.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Total
    Batch
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Batteries
    Included
    Enclosure
    Rating
    Each
    Polypropylene Body with Polypropylene Fittings
    3/8 NPT Male0.8 to 899,999.9 Gallons999,999 Gallons4 3/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K210000000
    1/2 NPT Male2 to 2099,999.9 Gallons999,999 Gallons5 1/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K22000000
    3/4 NPT Male3 to 3099,999.9 Gallons999,999 Gallons5 1/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K23000000
    1 NPT Male5 to 5099,999.9 Gallons999,999 Gallons5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K24000000
    1 1/2 NPT Male6 to 6099,999.9 Gallons999,999 Gallons6 1/2"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K25000000
    2 NPT Male10 to 10099,999.9 Gallons999,999 Gallons6 3/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K26000000
     
    Replacements for Flowmeters

    High-Temperature Flowmeters with Digital Display

    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeters with Digital Display.
    Check the flow rate of liquids up to 200° F from an easy-to-read digital display instead of a scale or dial. These flowmeters measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these flowmeters, use them only with clean, low-viscosity liquids. Mount them inline with your pipe system. Their fittings are polypropylene, which works with a wide range of chemicals. NEMA and IP rated, these flowmeters stand up to dust, weather, corrosion, and water from washdowns.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Each
    Polypropylene Body with Polypropylene Fittings
     
    3/8 NPT Male
    0.4 to 44 3/4"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K170000000
    0.8 to 84 3/4"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K11000000
     
    1/2 NPT Male
    2 to 205 1/8"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K12000000
     
    3/4 NPT Male
    3 to 305 1/4"5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K13000000
     
    1 NPT Male
    5 to 505 5/8"5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K14000000
     
    1 1/2 NPT Male
    6 to 606 1/2"6 1/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K15000000
     
    2 NPT Male
    10 to 1006 3/4"6 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K16000000
    20 to 2006 3/4"6 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K18000000
     
    Replacements for Flowmeters

    Portable Noncontact Flowmeters

    Image of ProductInUse. Front orientation. Contains MultipleImages. Flowmeters. Portable Noncontact Flowmeters.
    Image of Product. Front orientation. Contains MultipleImages. Flowmeters. Portable Noncontact Flowmeters.
    Often used to pinpoint flow issues, these flowmeters clamp onto pipe, so you can spot-check the flow rate at different points without disassembling your system. They measure by tracking the time it takes for ultrasonic waves to pass through your liquid, so they don’t need to come into contact with your liquid. As a result, they can be used with a wider range of liquids than other flowmeters.
    Flow for Pipe
    Size, gpm
    Temp.,
    ° F
    For Pipe
    Size
    1/2
    2
    4
    12
    28
    Speed,
    ft/sec
    Overall
    Ht.
    Accuracy
    Min.
    Max.
    Batteries
    Included
    Display
    Type
    Includes
    Each
    Polycarbonate Body
    1/2 to 40.2 to 304 to 55015 to 2,0000.03 to 1003 15/16"±1.0%-20320YesDigitalCarrying Case, Mounting Hardware, Optional Power Source and Cable, Ultrasonic Gel4416N11000000000
    1/2 to 280.2 to 304 to 55015 to 2,000130 to 18,000700 to 100,0000.03 to 1003 15/16"±1.0%-20320YesDigitalCarrying Case, Mounting Hardware, Optional Power Source and Cable, Ultrasonic Gel4416N1300000000
    2 to 284 to 55015 to 2,000130 to 18,000700 to 100,0000.03 to 1003 15/16"±1.0%-20320YesDigitalCarrying Case, Mounting Hardware, Optional Power Source and Cable, Ultrasonic Gel4416N1200000000
     
    Replacement Ultrasonic Gel

    Flowmeter/Totalizers for Oil and Fuel

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers for Oil and Fuel.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers for Oil and Fuel.
    Image of Product. Front orientation. Flowmeter Displays. Flowmeter/Totalizers for Oil and Fuel, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers for Oil and Fuel.

    Replacement Flowmeter

    Rotors

    Use these flowmeter/totalizers to measure both the flow rate and total flow volume of oil, gasoline, diesel fuel, and kerosene. They count how many times their turbine turns as liquid passes through them to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation. Rated NEMA 4 and IP65, they seal out dust and protect against washdowns.
    These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Flowmeter/Totalizers
    Flowmeter/Totalizers with Calibration
    Certificate Traceable to NIST
    Max. Volume
    Displayed
    Temp., ° F
    Temp., ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Min.
    Max.
    Each
    Min.
    Max.
    Each
    Display
    Type
    Each
    Each
    Turbine Flow Measurement
     
    Aluminum Body with Aluminum Fitting and 316 Stainless Steel Seal
    1/2 NPT Female1 to 104 3/16"±2%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K201000000001254352K202000000000Digital4352K51300000004352K6650000000
    3/4 NPT Female2 to 204 5/16"±1.5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K20300000001254352K20400000000Digital4352K5230000004352K666000000
    1 NPT Female0.3 to 34"±5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K672000000141404352K912000000———0———0
    1 NPT Female3 to 504"±1.5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K682000000141404352K922000000———0———0
    1 1/2 NPT Female10 to 1005 5/16"±1%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K2050000000001254352K20600000000Digital4352K5430000004352K668000000
    2 NPT Female20 to 2006"±0.75%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    -402504352K4100000000141404352K4200000000Digital4352K4000000———0
     
    Accessories for Flowmeters

    Socket-Connect Flowmeter/Totalizers with Remote Display

    Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. Use them to measure the rate and volume of liquid flowing through your system. They measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Batch totals are resettable but can be protected with a security code to prevent tampering. The reset function can also be disabled so that they operate as a cumulative totalizer. Cumulative totals cannot be reset. No matter the mounting orientation, they’ll measure flow correctly.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For a complete unit, you’ll need a display, a sensor, and a tee fitting.
    Displays
    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers with Remote Display, Displays.
    Displays are rated NEMA 4X and IP65 for protection against dust, weather, washdowns, and corrosion.
    Displays
    Brackets
    Temp.,
    ° F
    For Panel
    Cutout, mm
    Mounting Slot
    Maximum Total
    Volume Displayed
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    For DIN Panel
    Cutout Size
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Lg.
    Wd.
    No.
    of
    Each
    9,999 Gallons
    9,999 Liters
    ±0.5%180 psi @ 70° F331491/4969641YesIP65
    NEMA 4X
    4114K33500000003/16"3/4"44114K94000000
     

    Totalizers for Grease

    Image of Product. Front orientation. Flowmeters. Totalizers for Grease.
    Install this totalizer on your grease gun or valve to measure grease dispensing and reduce waste. They use positive displacement, so they measure the flow by passing specific volumes of liquid through a pair of oval gears. Their total can be reset. They measure flow accurately no matter the mounting orientation.
    These totalizers are calibrated with oil. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Total
    Batch
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Ht.
    Wd.
    Dp.
    Display
    Type
    Batteries
    Included
    Each
    Aluminum Body with Aluminum Fittings
    1/8 NPT Female9,999 Cubic Centimeters
    9,999 Ounces
    999 Cubic Centimeters
    99 Ounces
    ±3%10,000 psi @ 70° F-4130Neoprene
    Any Angle2 1/2"3"2 1/2"DigitalYes6727T11000000000
     

    High-Temperature Flowmeter/Totalizers

    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeter/Totalizers.
    With one meter, these flowmeter/totalizers measure the flow rate and total flow volume of high-temperature liquid up to 200° F. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow correctly no matter the mounting orientation.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Min.
    Max.
    Each
    Turbine Flow Measurement
     
    Polypropylene Body with Polypropylene Fitting and Fluoroelastomer Seal
    3/8 NPT Male0.8 to 84 3/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K310000000
    1/2 NPT Male2 to 205 1/8"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K32000000
    3/4 NPT Male3 to 305 1/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K33000000
    1 NPT Male5 to 505 5/8"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K34000000
    1 1/2 NPT Male6 to 606 1/2"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K35000000
    2 NPT Male10 to 1006 3/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K36000000
     
    Replacements for Flowmeters

    Flanged Flowmeter/Totalizers

    Image of Product. Front orientation. Flowmeters. Flanged Flowmeter/Totalizers.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flanged Flowmeter/Totalizers.

    Replacement Displays

    Using the flanged ends, securely install these flowmeter/totalizers in large, high-flow pipelines to measure the flow rate and total volume of liquid flowing through. They use ultrasonic waves to measure flow, so they don’t have any internal moving parts that can break or get stuck. You can reset the batch total, but you can't reset the cumulative total. They measure accurately in any mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Flange
    OD
    For Flange
    ANSI Class
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    3 Pipe Size
    2.06 to 3097 1/2"150
    13 1/4"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K61000000000Digital3777K6150000000
    4 Pipe Size
    3.58 to 5379"150
    13 3/16"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K6200000000Digital3777K625000000
     

    Socket-Connect Flowmeter/Totalizers

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.
    Image of Product. Front orientation. Flowmeter Displays. Socket-Connect Flowmeter/Totalizers, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    The unthreaded ends of these flowmeter/totalizers install into a PVC piping system, so you can measure the flow rate and volume of liquid passing through your system. Bond the joint together with PVC cement and primer. You can reset the batch total, but you can't reset the cumulative total. They measure flow correctly no matter the mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Turbine Flow Measurement—Turbine flowmeter/totalizers measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Ultrasonic Flow Measurement—Ultrasonic flowmeter/totalizers measure flow with ultrasonic waves, so they don’t have internal moving parts that can break or get stuck.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Turbine Flow Measurement
     
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    1/2 Male1 to 1080
    4 5/16"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T7110000000Digital4352K5130000000
    3/4 Male2 to 2080
    4 7/16"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T721000000Digital4352K523000000
    1 Male5 to 5080
    4 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T731000000Digital4352K533000000
    1 1/2 Male10 to 10080
    5 3/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T741000000Digital4352K543000000
    2 Male20 to 20080
    5 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T751000000Digital4352K553000000
     
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    3 Male2.06 to 30980
    6 5/8"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K5100000000Digital3777K615000000
    4 Male3.58 to 53780
    7 3/8"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K5200000000Digital3777K625000000
     
    Accessories for Flowmeters

    Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings

    Image of Product. Shown with 90° Display
Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings.
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeter Displays. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    Easy to remove for cleaning and maintenance, these flowmeter/totalizers connect to sanitary quick-clamp fittings (often called tri-clamp fittings) and measure the flow rate and volume of liquid passing through your system. You'll need a gasket and clamp to connect these to your line. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation.
    For use in hazardous locations, these flowmeter/totalizers are FM-approved. They’re also rated NEMA 4 to protect against weather and washdowns.
    These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    Flowmeter/Totalizers
    Replacement Displays
    Max. Volume
    Displayed
    Temp.,
    ° F
    Flowmeter/Totalizers
    Flowmeter/Totalizers with Calibration
    Certificate Traceable to NIST
    For Tube
    OD
    Connections
    Flow,
    gpm
    Flange
    OD
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Each
    Each
    Display
    Type
    Each
    Turbine Flow Measurement
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    3/4"Female1 to 100.984"5"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N110000000009011N21000000000Digital9011N4110000000
    1"Female2 to 201.984"5"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N12000000009011N2200000000Digital9011N412000000
    1 1/2"Female5 to 501.984"5 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N13000000009011N2300000000Digital9011N413000000
    2"Female10 to 1002.515"6 1/2"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N14000000009011N2400000000Digital9011N414000000
    2 1/2"Female20 to 2003.047"7"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N15000000009011N2500000000Digital9011N415000000
     
    Accessories for Flowmeters
    back to top