    22 Products

    Flow Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow Transmitters, Turbine Flow Measurement.

    Turbine Flow

    Measurement

    Send flow rate measurements to monitor and control equipment. Also known as transducers, these transmitters convert flow rate measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure flow correctly no matter their mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Turbine Flow Measurement—Turbine transmitters measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. The digital output sends flow data with a pulse, which is a spike of voltage. The higher the flow, the more pulses they send. The voltage of the pulse output matches the input voltage sent to the transmitters. These transmitters meet NSF/ANSI 61 for use with drinking water.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Pulse Freq.,
    Hz
    Each
    One Analog Transmitter/Digital Pulse Output—Wire Lead Connection
     
    Nylon Body with Nylon Fitting
    Turbine1/4 NPT Male0.026 to 0.651 3/4"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo36 to 9024386N2010000000
    Turbine3/8 NPT Male0.13 to 1.32 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo56 to 5654386N202000000
    Turbine3/8 NPT Male0.26 to 42 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo36 to 5534386N203000000
    Turbine3/8 NPT Male0.53 to 9.22 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo25 to 4354386N204000000
    Turbine3/4 NPT Male1.32 to 17.172 15/16"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo17 to 2274386N205000000
     

    Flowmeter/Totalizers

    Determine the flow rate and total volume of liquid flowing through your system with the same meter. To measure flow, these flowmeter/totalizers count how many times their turbine turns as liquid passes through. Use them only with clean, low-viscosity liquids to avoid clogging the turbine and other damage to these flowmeter/totalizers. You can reset the batch total, but you can’t reset the cumulative total. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    These flowmeter/totalizers are either calibrated with water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Choose a fitting material that is compatible with the liquid you're running through your line. IP rated, all seal out dust and can be lightly rinsed.
    Nylon Body with Nylon Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.

    Shown with 90°

    Display Adapter Kit

    Nylon fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Flowmeter/Totalizers
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K6320000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K232000000
     
    Accessories for Flowmeters

    Totalizers with Digital Display

    Image of Product. Front orientation. Flowmeters. Totalizers with Digital Display.
    A digital display makes it easy to check both the total amount of liquid that’s flowed through and the batch total. These totalizers are useful in applications where water needs to be batched and dispensed. You can reset the batch total, but you can't reset the cumulative total. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. They’re accurate in any mounting orientation. Mount them inline with your pipe system. Rated IP65, they seal out dust and can be lightly rinsed.
    These totalizers are calibrated with solvent. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from solvent.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow
    Total
    Batch
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Batteries
    Included
    Enclosure
    Rating
    Each
    Nylon Body
     
    Gallons
    1 NPT Female3 gpm to 30 gpm9,999 Gallons9,999 Gallons4"±5%150 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K750000000
     
    Liters
    1 NPT Female10 L/min to 100 L/min9,999 Liters9,999 Liters4"±5%150 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K76000000
     
    Gallons and Liters
    1 NPT Female0.3 gpm to 3 gpm999,999 Gallons
    999,999 Liters
    999,999 Gallons
    999,999 Liters
    4"±5%150 psi @ 70° F0130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K81000000
     

    Totalizers

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Totalizers, Nylon Body with 304 Stainless Steel/Nylon Fittings.
    Image of Specification. Top orientation. Contains Border. Analog Display. Totalizers.

    Nylon Body with 304 Stainless

    Steel/Nylon Fittings

    Analog Display

    Measure the total amount of liquid flowing through these totalizers. They total the volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Their total cannot be reset.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Totalizers
    Replacement
    Couplings
    Temp.,
    ° F
    Connections
    Flow, gpm
    Maximum Total Volume
    Displayed
    Inlet
    ID
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Each
    Pair
    Nylon Body with 304 Stainless Steel/Nylon Fittings
    1/2 NPT Male0.25 to 139,999,999 Gallons5/8"10"±1.5%100 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K4100000004119K77000000
    3/4 NPT Male0.25 to 229,999,999 Gallons5/8"11 1/2"±1.5%100 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K420000004119K7900000
    1 NPT Male0.75 to 509,999,999 Gallons3/4"10 3/4"±1.5%100 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K43000000———0
    1 1/2 NPT Male2 to 1009,999,999 Gallons1 1/2"9 5/8"±1.5%100 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K616000000———0
     
    Switches

    Totalizers for Oil

    Image of Product. Front orientation. Flowmeters. Totalizers for Oil.
    Measure the amount of light oil that flows through these totalizers. They use positive displacement, so they measure flow by passing specific volumes of liquid through a chamber. Their total can be reset. Manually or automatically turn them on, and they automatically shut down 40 seconds after flow stops. Their mounting orientation won’t affect their ability to measure flow correctly. Install these totalizers directly inline with your pipe system using the fittings on each end. The fittings are 316 stainless steel, so they resist impact better than plastic fittings.
    These totalizers are calibrated with water. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Cannot Be Sold Outside North America—Products cannot be sold outside North America due to restrictions.
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Maximum Total Volume
    Displayed
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Ht.
    Wd.
    Dp.
    Display
    Type
    Batteries
    Included
    Features
    Cannot Be Sold To
    Each
    Nylon Body with 316 Stainless Steel Fittings
    1 NPT Male2 to 30999,999.9 Gallons
    999,999.9 Liters
    999,999.9 Ounces
    ±0.5%60 psi @ 70° F33130Viton® Fluoroelastomer
    Any Angle5"6"4"DigitalYesAutomatic Start and StopOutside North America41935K480000000
     
    back to top