    A spring piston instead of a float allows these flowmeters to measure flow rate in any mounting orientation. As liquid passes through, it pushes an indicator up the scale, showing you the flow rate. They have union fittings on both ends, making it easy to position the scale so it’s visible.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Polysulfone Fitting—Polysulfone fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than polysulfone fittings.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Polysulfone Body with Polysulfone Fittings
     
    1 NPTF Male
    0.5 to 45 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K110000000
    1 to 75 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K12000000
    1 to 105 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K13000000
    1 to 165 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K14000000
    3 to 185 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K15000000
    4 to 285 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K16000000
     
    Polysulfone Body with Brass Fittings
     
    1/2 NPTF Female
    0.5 to 47 3/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K21000000
    1 to 77 3/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K22000000
    1 to 107 3/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K23000000
    1 to 167 3/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K24000000
     
    3/4 NPTF Male
    0.5 to 48 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K31000000
    1 to 108 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K28000000
    1 to 168 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K25000000
    4 to 288 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K27000000
     
    1 1/2 NPTF Female
    2 to 258 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K621000000
    5 to 508 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K622000000
    7 to 758 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K623000000
    10 to 1008 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K624000000
     
    2 NPTF Female
    2 to 258 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K631000000
    5 to 508 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K632000000
    7 to 758 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K633000000
    10 to 1008 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K634000000
     
    2 1/2 NPTF Female
    20 to 20010 3/4"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K64100000000
     
    3 NPTF Female
    25 to 27510 3/4"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K65100000000
     

    High-Temperature Flowmeters

    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeters, Female.
    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeters, Male.

    Female

    Male

    Measure the flow rate of high-temperature liquids. As your liquid flows through these flowmeters, it pushes an indicator up the scale, showing you the flow rate. Mount them vertically inline with your piping system, so liquid flows up from the bottom. They have union fittings, making it easy to position the scale so it’s visible. The fittings are plastic, so they work with a wide range of chemicals.
    These flowmeters are calibrated using water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Flow
    Temp.,
    ° F
    US Customary,
    gpm
    Metric,
    L/min
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    Each
    Polysulfone Body with Polypropylene Fittings
     
    3/8 NPT Male
    0.1 to 10.4 to 46 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K670000000
    0.2 to 20.75 to 7.56 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K68000000
     
    Polysulfone Body with Polysulfone Fittings
     
    3/8 NPT Male
    0.5 to 51.8 to 186 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K74000000
     
    1/2 NPT Male
    0.1 to 10.4 to 46 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K72000000
    0.2 to 20.75 to 7.56 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K73000000
    0.5 to 51.8 to 186 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K69000000
    1 to 105 to 37.57 1/2"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K66000000
     
    3/4 NPT Male
    1 to 105 to 37.57 1/2"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K71000000
     
    1 NPT Female
    0.5 to 62 to 2214 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K131000000
    1 to 104 to 4014 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K132000000
    2 to 206 to 7614 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K54000000
    3 to 3010 to 11014 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K55000000
    4 to 4015 to 15514 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K56000000
     
    2 NPT Female
    2 to 208 to 7818 7/8"±2%150 psi @ 70° F33200Fluoroelastomer
    VerticalUnion Fittings4400K14100000000
    6 to 10020 to 38018 7/8"±2%150 psi @ 70° F33200Fluoroelastomer
    VerticalUnion Fittings4400K5900000000
    20 to 13080 to 50018 7/8"±2%150 psi @ 70° F33200Fluoroelastomer
    VerticalUnion Fittings4400K6100000000
     
    Polysulfone Body with PVC Fittings
     
    1 1/2 NPT Female
    0.5 to 62 to 2214 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K151000000
    1 to 104 to 4014 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K152000000
    2 to 206 to 7614 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K153000000
    3 to 3023 to 11514 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K154000000
    4 to 4015 to 15514 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K155000000
     

    Flowmeters for High-Purity Liquids

    Image of Product. Front orientation. Flowmeters. Flowmeters for High-Purity Liquids.
    To avoid metal contaminating liquids, such as deionized water, these flowmeters are made entirely of plastic and rubber. As your liquid flows through, it pushes an indicator up the scale, showing you the flow rate. Mount these flowmeters vertically inline with your pipe system, so liquid flows up from the bottom. They have union fittings, making it easy to position the scale so it’s visible. The fittings are PVC, so they work with a wide range of chemicals.
    These flowmeters are calibrated using water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow, gpm
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    Each
    Polysulfone Body with PVC Fittings
     
    1/2 NPT Female
    0.05 to 0.510"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K690000000
    0.1 to 110"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K72000000
     
    3/4 NPT Female
    0.2 to 2.410"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K73000000
    0.5 to 510"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K74000000
     
    1 NPT Female
    0.76 to 7.611 3/4"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K75000000
    1 to 1011 3/4"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K76000000
    1.5 to 1511 3/4"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K77000000
    2 to 2011 3/4"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K78000000
     

    Any-Orientation Flowmeters for Oil

    Image of Product. Front orientation. Flowmeters. Any-Orientation Flowmeters for Oil.
    With a spring piston instead of a float, these flowmeters measure the flow rate of oil in any mounting orientation. As oil flows through, it pushes an indicator up the scale, showing you the flow rate. Install them inline with your piping system with the fittings on both ends. They’re union fittings, making it easy to position the scale so it’s visible.
    These flowmeters are calibrated with oil but can be used with other liquids. If you’re using these with a liquid other than oil, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Polysulfone Fitting—Polysulfone fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than polysulfone fittings.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    Each
    Polysulfone Body with Polysulfone Fittings
     
    1/2 NPTF Female
    0.5 to 57 3/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A710000000
    1 to 107 3/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A72000000
     
    3/4 NPTF Female
    1 to 107 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A73000000
    1 to 157 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A74000000
     
    1 NPTF Female
    1 to 157 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A75000000
    3 to 307 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A76000000
     
    Polysulfone Body with Brass Fittings
     
    1/2 NPTF Female
    0.5 to 57 3/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A51000000
    1 to 107 3/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A52000000
     
    3/4 NPTF Female
    1 to 107 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A53000000
    1 to 157 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A54000000
     
    1 NPTF Female
    1 to 157 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A55000000
    3 to 307 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A56000000
     

    Socket-Connect Flowmeters

    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeters.
    Easily install the unthreaded ends of these flowmeters into a PVC piping system. Bond the ends to PVC pipe with PVC cement and primer. They measure flow correctly no matter the mounting orientation. As liquid flows through the meter, it pushes an indicator up the scale, showing you the flow rate. They work with a wide range of chemicals since the fittings are made from PVC.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow,
    gpm
    Overall
    Ht.
    Accuracy
    For Pipe
    Schedule
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Polysulfone Body with PVC Fittings
     
    1 Male
    0.5 to 48 1/2"±5%40, 80
    Not Rated32140Buna-N
    Any Angle4197K410000000
    1 to 108 1/2"±5%40, 80
    Not Rated32140Buna-N
    Any Angle4197K43000000
    3 to 188 1/2"±5%40, 80
    Not Rated32140Buna-N
    Any Angle4197K45000000
    4 to 288 1/2"±5%40, 80
    Not Rated32140Buna-N
    Any Angle4197K46000000
     

    High-Temperature Panel-Mount Flowmeters

    Image of Product. Front orientation. Contains Annotated. Flowmeters. High-Temperature Panel-Mount Flowmeters, Male, Flowmeters.
    Image of Product. Front orientation. Contains Annotated. Flowmeters. High-Temperature Panel-Mount Flowmeters, Male, Flowmeters with Flow-Control Knob.

    Male

    Flowmeters

    Male, Flowmeters

    with Flow-Control

    Knob

    Install these flowmeters in an instrument panel to measure the flow rate of hot water and other liquids reaching up to 212° F. They should be mounted vertically, so liquid flows up from the bottom. As liquid flows through, it pushes an indicator up the scale, showing you the flow rate.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Flow-Control Knob—Flowmeters with a flow-control knob let you open and close the inlet valve to adjust the flow rate within the range.
    Flow
    Temp.,
    ° F
    Flowmeters
    Flowmeters with
    Flow-Control Knob
    US Customary,
    gpm
    Metric,
    L/min
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Each
    Each
    Polysulfone Body with Polysulfone Fittings
     
    3/8 NPT Male
    0.025 to 0.250.1 to 17"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K6600000004215K760000000
    0.1 to 10.4 to 47"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K670000004215K77000000
    0.2 to 20.75 to 7.57"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K680000004215K78000000
    0.5 to 51.8 to 187"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K690000004215K79000000
     
    1/2 NPT Male
    0.025 to 0.250.1 to 17"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K610000004215K71000000
    0.1 to 10.4 to 47"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K620000004215K72000000
    0.2 to 20.75 to 7.57"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K630000004215K73000000
    0.5 to 51.8 to 187"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K640000004215K74000000
     
    3/4 NPT Male
    1 to 105 to 37.58"6 13/16"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K650000004215K75000000
     