    Flowmeter/Totalizers

    Determine the flow rate and total volume of liquid flowing through your system with the same meter. To measure flow, these flowmeter/totalizers count how many times their turbine turns as liquid passes through. Use them only with clean, low-viscosity liquids to avoid clogging the turbine and other damage to these flowmeter/totalizers. You can reset the batch total, but you can’t reset the cumulative total. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    These flowmeter/totalizers are either calibrated with water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Choose a fitting material that is compatible with the liquid you're running through your line. IP rated, all seal out dust and can be lightly rinsed.
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVC Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, PVC Body.

    Shown with 90°

    Display Adapter Kit

    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T3110000000Digital4352K5130000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T321000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T331000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T341000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T351000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T42100000000Digital4352K1090000004352K1120000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T431000000Digital4352K513000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T441000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T451000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T461000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T471000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T49100000000Digital4352K1090000004352K112000000
     
    Accessories for Flowmeters

    Easy Read Flowmeters

    Image of Product. Style A. Front orientation. Style A. Easy Read Flowmeters.

    Style A

    A large dial instead of a scale makes it easier to read the flow rate from a distance. As liquid flows through these flowmeters, it pushes a needle along the dial, showing you the flow rate. They measure flow correctly no matter the mounting orientation.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a direction of flow that matches your pipe system, so you don't have to tilt your head to read the dial.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Temp.,
    ° F
    Style
    Flow,
    gpm
    Dial
    Size
    End-to-End
    Lg.
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Direction
    of Flow
    Each
    PVC Body with PVC Fittings
     
    1/4 NPT Female
    A0 to 12 1/2"3 5/8"3 5/16"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T210000000
    A0 to 13 1/2"3 5/8"4 3/8"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T28000000
    A0 to 22 1/2"3 5/8"3 5/16"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T27000000
    A0 to 23 1/2"3 5/8"4 3/8"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T29000000
     
    1/2 NPT Female
    A0 to 52 1/2"5 3/4"3 5/16"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K371000000
    A0 to 102 1/2"5 3/4"3 5/16"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T36000000
    A0 to 103 1/2"5 3/4"4 3/8"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T38000000
     
    1 NPT Female
    A0 to 203 1/2"3 1/4"5 13/16"±2%100 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K171000000
    A0 to 403 1/2"3 1/4"5 13/16"±2%100 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K172000000
     
    2 NPT Female
    A0 to 603 1/2"3 1/4"7 1/16"±2%100 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K18100000000
    A0 to 1003 1/2"3 1/4"7 1/16"±2%100 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K18200000000
     

    Socket-Connect Flowmeter/Totalizers

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.
    Image of Product. Front orientation. Flowmeter Displays. Socket-Connect Flowmeter/Totalizers, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    The unthreaded ends of these flowmeter/totalizers install into a PVC piping system, so you can measure the flow rate and volume of liquid passing through your system. Bond the joint together with PVC cement and primer. You can reset the batch total, but you can't reset the cumulative total. They measure flow correctly no matter the mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Turbine Flow Measurement—Turbine flowmeter/totalizers measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Ultrasonic Flow Measurement—Ultrasonic flowmeter/totalizers measure flow with ultrasonic waves, so they don’t have internal moving parts that can break or get stuck.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Turbine Flow Measurement
     
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    1/2 Male1 to 1080
    4 5/16"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T7110000000Digital4352K5130000000
    3/4 Male2 to 2080
    4 7/16"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T721000000Digital4352K523000000
    1 Male5 to 5080
    4 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T731000000Digital4352K533000000
    1 1/2 Male10 to 10080
    5 3/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T741000000Digital4352K543000000
    2 Male20 to 20080
    5 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T751000000Digital4352K553000000
     
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    3 Male2.06 to 30980
    6 5/8"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K5100000000Digital3777K615000000
    4 Male3.58 to 53780
    7 3/8"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K5200000000Digital3777K625000000
     
    Accessories for Flowmeters

    Flanged Flowmeter/Totalizers

    Image of Product. Front orientation. Flowmeters. Flanged Flowmeter/Totalizers.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flanged Flowmeter/Totalizers.

    Replacement Displays

    Using the flanged ends, securely install these flowmeter/totalizers in large, high-flow pipelines to measure the flow rate and total volume of liquid flowing through. They use ultrasonic waves to measure flow, so they don’t have any internal moving parts that can break or get stuck. You can reset the batch total, but you can't reset the cumulative total. They measure accurately in any mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Flange
    OD
    For Flange
    ANSI Class
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    3 Pipe Size
    2.06 to 3097 1/2"150
    13 1/4"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K61000000000Digital3777K6150000000
    4 Pipe Size
    3.58 to 5379"150
    13 3/16"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K6200000000Digital3777K625000000
     

    Socket-Connect Flowmeter/Totalizers with Remote Display

    Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. Use them to measure the rate and volume of liquid flowing through your system. They measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Batch totals are resettable but can be protected with a security code to prevent tampering. The reset function can also be disabled so that they operate as a cumulative totalizer. Cumulative totals cannot be reset. No matter the mounting orientation, they’ll measure flow correctly.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For a complete unit, you’ll need a display, a sensor, and a tee fitting.
    Tee Fittings
    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers with Remote Display, Tee Fittings.
    Tee fittings mount inline with your pipe. They have two unthreaded socket ends that bond to unthreaded PVC pipe with PVC cement and primer.
    Temp.,
    ° F
    Inlet/Outlet Connection
    Sensor Connection
    Pipe
    Schedule
    Flow, gpm
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Mounting
    Position
    Each
    PVC Body
    1/2 Socket Connect Female Inlet Pipe × 1/2 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    1 to 18.9180 psi @ 70° F33149Any Angle4114K2310000000
    3/4 Socket Connect Female Inlet Pipe × 3/4 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    1.7 to 33.2180 psi @ 70° F33149Any Angle4114K232000000
    1 Socket Connect Female Inlet Pipe × 1 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    2.7 to 53.9180 psi @ 70° F33149Any Angle4114K233000000
    1 1/2 Socket Connect Female Inlet Pipe × 1 1/2 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    6.4 to 126.9180 psi @ 70° F33149Any Angle4114K235000000
    2 Socket Connect Female Inlet Pipe × 2 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    10.5 to 209.2180 psi @ 70° F33149Any Angle4114K236000000
    3 Socket Connect Female Inlet Pipe × 3 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    23 to 460.8180 psi @ 70° F33149Any Angle4114K238000000
     

    Calibration Columns

    Image of Product. Front orientation. Calibration Columns.
    Calibrate the flow rate of metering pumps. A graduated scale with zero at the top lets you easily see how much fluid is lost over the course of a one-minute test. This will tell you your pump’s flow rate. Periodic testing helps alert you to issues in your system, such as worn or dirty valves. Checking the flow rate after performing maintenance ensures your pump is working properly.
    Install the column between your reservoir and pump. They require shutoff access to your reservoir and an on/off valve (not included) at the point where they connect to your system. To start the test, open the on/off valve as the system is running to fill the column with fluid up to the zero mark. Shut off the valve and wait one minute before observing the liquid level in the column. After you've taken the reading, close the on/off valve to the column and reopen access to the reservoir.
    PVC Body—PVC calibration columns are a good choice when working with water.
    Volume
    Graduations
    Pipe
    Connections
    Ht.
    Flow Rate
    Range, gph
    Imperial,
    gal.
    Metric,
    ml
    Imperial,
    gph
    Metric,
    ml/min
    Temp. Range,
    ° F
    Mounting
    Position
    For Use
    With
    Each
    PVC Body with PVC Fittings
     
    Gallons per Hour, Milliliters per Minute
    1/2 NPT Female12 1/2"0 to 1.51.51000.10532 to 140VerticalWater4446K71000000
    1/2 NPT Female16 1/4"0 to 442500.251032 to 140VerticalWater4446K7200000
    3/4 NPT Female16"0 to 885000.252032 to 140VerticalWater4446K7300000
    3/4 NPT Female25"0 to 16161,0000.252032 to 140VerticalWater4446K7400000
    1 NPT Female24"0 to 32322,00015032 to 140VerticalWater4446K75000000
    1 NPT Female34"0 to 64644,000110032 to 140VerticalWater4446K76000000
    2 NPT Female27"0 to 16016010,000550032 to 140VerticalWater4446K77000000
    2 NPT Female46"0 to 32032020,000550032 to 140VerticalWater4446K78000000
     

    Flow Sights for Chemicals

    Image of Product. Front orientation. Flow Sights. Flow Sights for Chemicals.
    To withstand corrosive chemical solutions, these sights have a PVC body, a fluoroelastomer seal, and an acrylic window. The large tubular window provides an unobstructed view of your process media for checking movement, clarity, and color from multiple angles.
    Window
    Pipe
    Size
    Thread
    Type
    Gender
    Temp. Range,
    ° F
    Lg.
    Type
    End-to-End
    Lg.
    Ht.
    Max. Pressure
    @ Temp.
    Direction
    of Flow
    For Use
    With
    Each
    No Indicator
     
    PVC Body
    1/2
    NPT
    Female40 to 1402 1/4"Tubular4 3/4"2 1/2"110 psi @ 70° FAny DirectionChemicals4338K210000000
    3/4
    NPT
    Female40 to 1402 1/4"Tubular4 3/4"2 1/2"110 psi @ 70° FAny DirectionChemicals4338K23000000
    1
    NPT
    Female40 to 1402 1/4"Tubular5 1/4"3"110 psi @ 70° FAny DirectionChemicals4338K25000000
    1 1/2
    NPT
    Female40 to 1402 1/2"Tubular5 7/8"3 1/2"110 psi @ 70° FAny DirectionChemicals4338K27000000
    2
    NPT
    Female40 to 1403 1/8"Tubular7 3/8"4"110 psi @ 70° FAny DirectionChemicals4338K29000000
     
    back to top