    30 Products

    Flow Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow Transmitters, Turbine Flow Measurement.

    Turbine Flow

    Measurement

    Send flow rate measurements to monitor and control equipment. Also known as transducers, these transmitters convert flow rate measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure flow correctly no matter their mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Turbine Flow Measurement—Turbine transmitters measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. The digital output sends flow data with a pulse, which is a spike of voltage. The higher the flow, the more pulses they send. The voltage of the pulse output matches the input voltage sent to the transmitters. These transmitters meet NSF/ANSI 61 for use with drinking water.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Pulse Freq.,
    Hz
    Each
    One Analog Transmitter/Digital Pulse Output—Wire Lead Connection
     
    Nylon Body with Nylon Fitting
    Turbine1/4 NPT Male0.026 to 0.651 3/4"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo36 to 9024386N2010000000
    Turbine3/8 NPT Male0.13 to 1.32 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo56 to 5654386N202000000
    Turbine3/8 NPT Male0.26 to 42 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo36 to 5534386N203000000
    Turbine3/8 NPT Male0.53 to 9.22 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo25 to 4354386N204000000
    Turbine3/4 NPT Male1.32 to 17.172 15/16"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo17 to 2274386N205000000
     
    Brass Body with Brass Fitting
    Turbine3/8 NPT Male0.5 to 2.112 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo132 to 5594386N206000000
    Turbine3/8 NPT Male0.8 to 6.62 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo46 to 3834386N207000000
     

    Flanged Totalizers for Drinking Water

    Image of Product. Front orientation. Flowmeters. Flanged Totalizers for Drinking Water, Bronze Body, Elliptical Flange.
    Image of Product. Front orientation. Flowmeters. Flanged Totalizers for Drinking Water, Bronze Body, Round Flange.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. Flanged Totalizers for Drinking Water, Bronze Body.

    Bronze Body

    Elliptical Flange

    Bronze Body

    Round Flange

    Bronze Body

    Analog Display

    Flanged ends let you securely integrate these totalizers into large drinking water pipelines to measure the cumulative amount of water flowing through them. They meet NSF/ANSI 61, so they're safe to use with drinking water. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Their total cannot be reset.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Flanges—The elliptical flange kit (sold separately) lets you convert elliptical flanges to NPT female connections.
    Totalizers
    Flanges
    Flange
    Temp.,
    ° F
    Bolt
    Connections
    OD
    Type
    Flow, gpm
    Maximum Total Volume
    Displayed
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Hole
    Dia.
    Circle
    Dia.
    No. of
    Holes
    Each
    Each
    Bronze Body with Brass Fittings
    2 Pipe Size
    5 7/8"Elliptical4 to 35099,999,000 Gallons10"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog5/8"4"24189K310000000004189K410000000
    3 Pipe Size
    7 1/2"Round5 to 53099,999,000 Gallons12"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog3/4"6"44189K3200000000———0
    4 Pipe Size
    8 7/8"Round9 to 1,35099,999,000 Gallons14"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog3/4"7 1/2"84189K3300000000———0
    6 Pipe Size
    11 1/8"Round25 to 2,70099,999,000 Gallons18"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog7/8"9 1/2"84189K3400000000———0
     

    Totalizers for Drinking Water

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Totalizers for Drinking Water, Brass Body, Female.

    Brass Body

    Female

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Totalizers for Drinking Water, Brass Body, Male.

    Brass Body

    Male

    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. Totalizers for Drinking Water, Brass Body.

    Brass Body

    Analog Display

    Meeting NSF/ANSI 61, these totalizers measure the cumulative amount of drinking water flowing through them. They use positive displacement, so they measure the flow by passing specific volumes of liquid through their chamber. Their total cannot be reset. Install them directly inline with your pipe system using the fittings on each end. They have a low-flow indicator to detect leaks in your system.
    These totalizers are calibrated with drinking water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from drinking water.
    Temp.,
    ° F
    Connections
    Flow, gpm
    Maximum Total Volume
    Displayed
    Inlet
    ID
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Features
    Each
    Brass Body with Bronze Fittings
    1/2 NPT Male0.5 to 2010,000,000 Gallons5/8"12 1/2"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K210000000
    3/4 NPT Male0.5 to 2010,000,000 Gallons5/8"12 3/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K22000000
    3/4 NPT Male0.75 to 3010,000,000 Gallons3/4"14 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K61000000
    1 NPT Male0.75 to 3010,000,000 Gallons3/4"14 1/2"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K62000000
    1 NPT Male1 to 5010,000,000 Gallons1"16 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K23000000
    1 1/2 NPT Female2 to 100100,000,000 Gallons1 1/2"12 5/8"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K2500000000
    2 NPT Female2.5 to 160100,000,000 Gallons2"15 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K2600000000
     

    Fixed-Set-Point Flow Switches for Drinking Water

    Image of Product. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches for Drinking Water.
    Factory set to activate equipment when your drinking water system reaches a fixed level, these flow switches are easier to install than adjustable flow switches. They meet NSF/ANSI 61, so they're safe to use with drinking water. They actuate when your system’s flowing water pushes their paddle into a set position. These switches are single pole, single throw (SPST) and turn one device from off to on. IP rated, they seal out dust and can be lightly rinsed. They're accurate in any mounting position.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Pipe
    Connections
    Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage
    Max. Switching Current
    @ Voltage
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Food Industry
    Std.
    Each
    Noryl Body with Threaded Brass Fittings
    1/2 NPT Female0.6145 psi @ 70° F-4 to 212230V AC/48V DC1 amp @ 230V AC
    1 amp @ 48V DC
    2"IP65
    CE Marked
    NSF/ANSI 61
    4646N110000000
     

    Remote-Reading Totalizers for Drinking Water

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Remote-Reading Totalizers for Drinking Water, Brass Body, Female.
    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Remote-Reading Totalizers for Drinking Water, Brass Body, Male.

    Brass Body

    Female

    Brass Body

    Male

    Image of Specification. Top orientation. ZoomedIn view. Contains Border. Analog Display. Remote-Reading Totalizers for Drinking Water, Brass Body.
    Image of Product. Front orientation. ZoomedIn view. Flowmeter Displays. Remote-Reading Totalizers for Drinking Water.

    Analog Display

    Replacement Remote Displays

    Often used in hard-to-access areas, these totalizers let you monitor the total amount of drinking water flowing through them up to 250 feet away. They meet NSF/ANSI 61 for safe use with drinking water. They use positive displacement, so they measure flow by passing specific volumes of liquid through a chamber. Their total cannot be reset. Mount them inline with your pipe system. They have a low-flow indicator to detect leaks in your system.
    These totalizers are calibrated with drinking water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from drinking water.
    Totalizers
    Replacement
    Remote Displays
    Temp.,
    ° F
    Connections
    Flow, gpm
    Maximum Total Volume
    Displayed
    Inlet
    ID
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Features
    Each
    Each
    Brass Body with Bronze Fittings
    1/2 NPT Male0.5 to 2099,999,999 Gallons5/8"12 1/2"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K9100000003786K110000000
    3/4 NPT Male0.5 to 2099,999,999 Gallons5/8"12 3/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K920000003786K11000000
    3/4 NPT Male0.75 to 3099,999,999 Gallons3/4"14 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K810000003786K11000000
    1 NPT Male0.75 to 3099,999,999 Gallons3/4"14 1/2"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K820000003786K11000000
    1 NPT Male1 to 5099,999,999 Gallons1"16 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K930000003786K11000000
    1 1/2 NPT Female2 to 10099,999,999 Gallons1 1/2"12 5/8"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K95000000003786K12000000
    2 NPT Female2.5 to 16099,999,999 Gallons2"15 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K96000000003786K12000000
     