McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    8 Products

    Fluke Water-Resistant Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Water-Resistant Multimeters.
    For taking electrical measurements in washdown environments, choose the durability and quality of Fluke multimeters with an IP67-rated housing.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Hardware Features
    Display
    Count
    Includes
    Enclosure
    Rating
    Each
    Each
    True RMS AC Calculation
    28 IICAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%1010Overload Protection6,000Alligator Clips, Temperature Probe, Test LeadsIP67
    0000000000000000000000000000
     

    Fluke High-Accuracy Multimeters

    Image of Product. Front orientation. Multimeters. Fluke High-Accuracy Multimeters.
    These Fluke multimeters provide results at least twice as accurate as standard Fluke multimeters. Fluke is known for quality and durability.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Hardware Features
    Display
    Count
    Includes
    Each
    Each
    True RMS AC Calculation
    87VCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%1010Lead Storage, Overload Protection20,000Alligator Clips, Temperature Probe, Test Leads00000000000000000000000000000
    87V/E2CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%1010Lead Storage, Overload Protection20,000Alligator Clips, Carrying Case, Magnetic Hanger, Temperature Probe, Test Leads000000000000000000000000000
     

    Fluke Hazardous Location Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Hazardous Location Multimeters.
    These Fluke multimeters are rated for environments where hazardous material is present. They take voltage, resistance, and other electrical measurements. Multimeters have durable sealed housing and are rated IP67 for protection from washdowns and temporary submersion.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Hazardous Location Rating—Indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Display
    Count
    Hazardous Location Rating
    NEC Hazardous Location
    Temp. Classification
    Each
    True RMS AC Calculation
    28 II ExCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%10106,000ATEX I M1 Ex Ia I Ma; ATEX II 2 G Ex Ia IIC T4 Gb; Ex Ia IIC T4; IEC Zone 1 Groups IIC, IIB, IIA; IECEx Ex Ia I Ma; IECEx Ex Ia IIC T4 Gb; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 1 Groups IIC, IIB, IIA; AEx Ia IIC T4T4 (275° F)0000000000000000
     

    Data-Logging Multimeters

    Image of Product. Front orientation. Multimeters. Data-Logging Multimeters.
    Identify intermittent issues such as voltage spikes and temporary power flow problems—these meters record measurements from electrical tests over time. Review data in real time or save it for future analysis.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Data Log
    Cap.
    Electrical Safety Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Display
    Count
    Includes
    Each
    True RMS AC Calculation
    10,000CAT III, 1,000V; CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%101040,000Temperature Probe, Test Leads00000000000000
     
    back to top