Filter by
Manufacturer
For Fluke Model Number
Test End Component
Electrical Safety Rating
Connection End Shape
Electrical Connection
Test End Type
Current
Digital Display Type
Display Type
Calculation Features
Display Features
DFARS Specialty Metals
Software Features
Display Count
Magnetic Fluke Multimeter Hangers
![]() | ![]() |
Free up your hands while using your Fluke multimeter by suspending it from this hanger.
Mfr. Model No. | For Fluke Model No. | Each | ||
---|---|---|---|---|
TPAK | 77IV, 83V, 87V, 88V, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 789, 1577, 1587 | 0000000 | 000000 |
Fluke Test Lead Sets
![]() | ![]() |
Model Number TL71 | Model Number TL75 |
Connect to Fluke multimeters with a set of red and black test leads.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | Test End | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Certification | No. of Cords | Cord Lg. | Color | Test End Material | Pair | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TL71 | 27 II, 28 II, 83V, 87V, 88V, 114, 115, 116, 117, 175, 177, 179, 233, 787, 789 | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 000000 | |
TL75 | 83V, 87V, 113, 175, 177, 179, 287, 289, 787, 789 | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 |
Fluke Test Lead Kits
![]() |
These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Includes | Cord Lg. | Color | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
TL220 | 27 II, 28 II, 83V, 87V, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 373, 374, 787, 789 | 1,000 | 1,000 | 10 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Plunger Style Alligator Clips | 59" | Black, Red | 0000000 | 0000000 | |
TLK-225 | 27 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 1587 | 1,000 | 1,000 | 1 | CAT IV, 600V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Grabbers Two Retractable Precision Hooks Pouch | 59" | Black, Red | 0000000 | 000000 |
Fluke Current-Sensing Test Leads
![]() |
Current Clamp |
Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
Mfr. Model No. | Test End | For Max. Cord Dia. | Connection End | AC Current, amp | Current Accuracy | Current Output Signal per amp Supplied, mA | For Current Range | AC Voltage, V AC | Electrical Safety Rating | Freq. Range | Jaw Opening | For Fluke Model No. | Cord Lg. | Batteries Req. | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures AC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
i400 | Current Clamp | 1.25" | Sheathed Standard Banana Plug | 1 to 400 | 2% | 1.000 | 1 amp to 400 amp | 1,000 | CAT IV, 600V | 5 Hz to 20 kHz | 1.25" | 27 II, 28 II, 77IV, 83V, 87V, 179, 287, 289, 787, 789, 1577, 1587 | 59" | No | 0000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Tips
![]() |
Adapt Fluke test leads to perform electrical tests in tight spaces. Attach these tips to test leads that have 4 mm banana plugs.
Test End | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | For Fluke Model No. | Test End Component | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Color | Material | Insulation Material | Pair | ||
TP1 | 83V, 87V, 175, 177, 179, 373, 374, 376, 381, 787, 789, T+PRO, T5-1000, T5-600 | Needle Tip | Standard Banana Jack | 1,000 | 1,000 | 10 | CAT II, 1,000V | Black, Red | Stainless Steel | Polypropylene | 0000000 | 000000 |
Fluke Multimeter Cases
![]() | ![]() |
Fabric Case | Tool Bag |
Mfr. Model No. | Case Type | For Fluke Model No. | Each | ||
---|---|---|---|---|---|
C25 | Fabric Case | 83V, 87V, 88V, 175, 177, 179, 787, 789, 1577, 1587 | 0000000 | 000000 | |
C550 | Tool Bag | 27 II, 28 II, 77IV, 83V, 87V, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 324, 355, 373, 374, 376, 381, 787, 789, 1577, 1587, 3000 FC, T5-600, T5-1000 | 0000000 | 000000 |
Fluke Instrumentation Process Control Multimeters
![]() |
With these combination loop calibrators and multimeters, check for current control loop issues in PLCs, motors, and fans in addition to taking other electrical measurements. When used as a loop calibrator, the current input as well as the percentage of the input scale is shown on the dual display, giving you quick diagnostic information. Fluke is known for quality and durability.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
789 | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 0.44 | 0.44 | Overload Protection | 4,000 | Alligator Clips, Test Leads | 000000 | 000000000 | 00000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Sensors
![]() |
Model Number 80TK |
Take temperature readings with a Fluke multimeter.
Model Number 80TK—Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm standard banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.
Mfr. Model No. | For Fluke Model No. | Temp. Range, ° F | AC Voltage, V AC | DC Voltage, V DC | Test End Component | Connection End | Cord Lg. | Test End Insulation Material | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
80TK | 27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789 | -40 to 500 | 24 | 60 | Needle Tip | Sheathed Standard Banana Plug | 39" | PTFE | 0000000 | 0000000 |