Filter by
Measures
Display Type
Electrical Safety Rating
Measurement Units
AC Calculation
Batteries Included
Calculation Features
System of Measurement
Software Features
Display Features
DFARS Specialty Metals
Fluke Multimeters
![]() |
Rely on the quality and durability of Fluke multimeters when taking voltage, resistance, and other electrical measurements.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, μA | Max. DC Current, μA | Hardware Features | Display Count | Includes | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
116 | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance, Temperature | 600 | 600 | 0.5% | 600 | 600 | Overload Protection | 6,000 | Temperature Probe, Test Leads | 00000000 | 0000000 | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke High-Accuracy Multimeters
![]() |
These Fluke multimeters provide results at least twice as accurate as standard Fluke multimeters. Fluke is known for quality and durability.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
179 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 10 | 10 | Lead Storage, Overload Protection | 6,000 | Temperature Probe, Test Leads | 0000000 | 0000000 | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
87V | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Lead Storage, Overload Protection | 20,000 | Alligator Clips, Temperature Probe, Test Leads | 0000000 | 000000 | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
87V/E2 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Lead Storage, Overload Protection | 20,000 | Alligator Clips, Carrying Case, Magnetic Hanger, Temperature Probe, Test Leads | 0000000 | 000000 | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Data-Logging Multimeters
![]() |
Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Software—To download and analyze data on a computer, software is required (not included). Connect your multimeter to a computer with the included USB cord.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Data Log Cap. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 0000000 | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 | 0000000 | 00000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Insulation-Testing Multimeters
![]() |
Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, mA | Max. DC Current, mA | Hardware Features | Display Count | Includes | Enclosure Rating | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1587 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test Leads | IP40 | 0000000 | 0000000 | 00000000 | 000000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Water-Resistant Multimeters
![]() |
For taking electrical measurements in washdown environments, choose the durability and quality of Fluke multimeters with an IP67-rated housing.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Enclosure Rating | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
28 II | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | IP67 | 000000 | 0000000 | 00000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Hazardous-Location Multimeters
![]() |
These Fluke multimeters are rated for environments where hazardous material is present. They take voltage, resistance, and other electrical measurements. Multimeters have durable sealed housing and are rated IP67 for protection from washdowns and temporary submersion.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Hazardous Location Rating—Indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Hazardous Location Rating | NEC Hazardous Location Temp. Classification | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
28 II Ex | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | 6,000 | ATEX I M1 Ex Ia I Ma; ATEX II 2 G Ex Ia IIC T4 Gb; Ex Ia IIC T4; IEC Zone 1 Groups IIC, IIB, IIA; IECEx Ex Ia I Ma; IECEx Ex Ia IIC T4 Gb; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 1 Groups IIC, IIB, IIA; AEx Ia IIC T4 | T4 (275° F) | 0000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Clamp-on-Jaw Multimeters
![]() |
Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Test Leads | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mfr. Model No. | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Display Count | Includes | Each | Each | Pair | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
325 | 1.18" | CAT III, 600V; CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature | 600 | 600 | 1% | 400 | 6,000 | Carrying Case, Temperature Probe, Test Leads | 00000000 | 0000000 | 00000000 | 0000000 | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Sensors
![]() | ![]() |
Model Number 80BK-A | Model Number 80TK |
Take temperature readings with a Fluke multimeter.
Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Model Number 80TK—Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm standard banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.
Mfr. Model No. | For Fluke Model No. | Temp. Range, ° F | AC Voltage, V AC | DC Voltage, V DC | Test End Component | Connection End | Cord Lg. | Test End Insulation Material | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40 to 500 | — | — | Needle Tip | Sheathed Standard Banana Jack | 39" | PTFE | 0000000 | 000000 | |
80TK | 27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789 | -40 to 500 | 24 | 60 | Needle Tip | Sheathed Standard Banana Plug | 39" | PTFE | 0000000 | 000000 |
Fluke Oscilloscope/Multimeters
![]() |
Perform electrical tests, record data, and see a graph of electrical waveforms with this combination multimeter and oscilloscope. Fluke oscilloscope/multimeters are known for quality and durability.
To download and analyze data on a computer, software is required (not included).
When used as an oscilloscope, the oscilloscope/multimeter is most accurate when the frequency is at least five times the maximum signal frequency you intend to measure.
True RMS AC Calculation—The multimeter function is true RMS, so it accurately takes AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. This 5,000-count oscilloscope/multimeter shows numbers up to 4,999.
Mfr. Model No. | No. of Digital Channels | Freq., MHz | Electrical Safety Rating | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Display Count | Data Log Cap. | Includes | Certification | Measures | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
123B | 2 | 0 to 20 | CAT IV, 600V | 600 | 600 | 0.5% | 5,000 | 512 | Alligator Clips, Battery Charger, BNC Adapter, Probe Tips, Test Leads | CSA Certified | AC Voltage, Capacitance, Continuity, DC Voltage, Temperature | Yes | 0000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||