About Safety Ratings for Electrical Testing
More
Fluke High-Accuracy Data-Logging Thermometers



Store up to 500 readings on these thermometers and determine temperature within ±0.75° F accuracy.
Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
The optional type K probe (sold separately) connects to your thermometer to measure temperatures up to 537° C or 1000° F.
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Probe Inputs | Temperature Range | Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Manufacturer Part No. | Specifications Met | Batteries Included | Each | |
Thermometers | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 53-2B | CE Marked, CSA Certified | Yes | 00000000 | 0000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 54-2B | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Thermometers with NIST Certificate | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 53-2B | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 54-2B | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Optional Type K Probe (8 3/8" Lg.) | 00000000 | Each | 0000000 |
Fluke High-Accuracy Hand-Held Thermometers



Designed for laboratory applications, these thermometers determine temperature within ±0.75° F accuracy.
Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
The optional type K probe (sold separately) connects to your thermometer to measure temperatures up to 537° C or 1000° F.
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Probe Inputs | Temperature Range | Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Manufacturer Part No. | Specifications Met | Batteries Included | Each | |
Thermometers | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 51-2 | CE Marked, CSA Certified | Yes | 00000000 | 0000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 52-2 | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Thermometers with NIST Certificate | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 51-2 | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 52-2 | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Optional Type K Probe (8 3/8" Lg.) | 00000000 | Each | 0000000 |
Fluke High-Accuracy Multimeters

These Fluke multimeters provide results at least twice as accurate as standard Fluke multimeters. Fluke is known for quality and durability.
True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
Multimeters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | ||||||||||||
179 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 10 | 10 | Lead Storage, Overload Protection | 6,000 | Temperature Probe, Test Leads | 0000000 | 0000000 |
87V | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Lead Storage, Overload Protection | 20,000 | Alligator Clips, Temperature Probe, Test Leads | 0000000 | 000000 |
87V/E2 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Lead Storage, Overload Protection | 20,000 | Alligator Clips, Carrying Case, Magnetic Hanger, Temperature Probe, Test Leads | 0000000 | 000000 |
Multimeters with Calibration Certificate | ||||||||||||
True RMS AC Calculation | ||||||||||||
179 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 10 | 10 | Lead Storage, Overload Protection | 6,000 | Temperature Probe, Test Leads | 00000000 | 000000 |
87V | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Lead Storage, Overload Protection | 20,000 | Alligator Clips, Temperature Probe, Test Leads | 00000000 | 000000 |
87V/E2 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Lead Storage, Overload Protection | 20,000 | Alligator Clips, Carrying Case, Magnetic Hanger, Temperature Probe, Test Leads | 00000000 | 000000 |
Fluke Multimeters

Rely on the quality and durability of a Fluke multimeter when taking voltage, resistance, and other electrical measurements.
True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current | Max. DC Current | Hardware Features | Display Count | Includes | Each | |
Multimeters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | ||||||||||||
116 | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 600 | 600 | 0.5% | 600 µA | 600 µA | Overload Protection | 6,000 | Temperature Probe, Test Leads | 00000000 | 0000000 |
Multimeters with Calibration Certificate | ||||||||||||
True RMS AC Calculation | ||||||||||||
116 | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 600 | 600 | 0.5% | 600 µA | 600 µA | Overload Protection | 6,000 | Temperature Probe, Test Leads | 00000000 | 000000 |
Fluke Wireless Remote-Reading Multimeters

A wireless connection transmits electrical measurements from the multimeter to a separate display, so you can take measurements in hard-to-reach or potentially dangerous locations. Fluke multimeters are known for quality and durability.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Fluke 233 has a detachable display that communicates with the multimeter using built-in low-power wireless technology. The Fluke 233 with calibration certificate includes a document stating that it has passed a test for accuracy.
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current | Max. DC Current | Hardware Features | Display Count | Includes | Each | |
Multimeters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | ||||||||||||
233 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.25% | 10 A | 10 A | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | 000000 | 0000000 |
Multimeters with Calibration Certificate | ||||||||||||
True RMS AC Calculation | ||||||||||||
233 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.25% | 10 A | 10 A | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | 00000000 | 000000 |
Fluke Data-Logging Multimeters
Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
To download and analyze data on a computer, software is required (not included).
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 50,000-count multimeters show numbers up to 49,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.

Manufacturer Model Number | Data Log Capacity | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
Multimeters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 0000000 |
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 |
Multimeters with Calibration Certificate | |||||||||||||
True RMS AC Calculation | |||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 |
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 00000000 |
Download and analyze data from a Fluke data-logging multimeter. Connect your multimeter to a computer with the included USB cord.
Manufacturer Model Number | For Fluke Model Number | For Operating System | Each | |
FVF-SC2 | 287, 289 | Windows 7 and earlier | 0000000 | 0000000 |
Fluke Insulation Testing Multimeters

Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, mA | Max. DC Current, mA | Hardware Features | Display Count | Includes | Environmental Rating | Each | |
Multimeters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||
1587 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test Leads | IP40 | 0000000 | 000000000 |
Multimeters with Calibration Certificate | |||||||||||||
True RMS AC Calculation | |||||||||||||
1587 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test Leads | IP40 | 00000000 | 00000000 |
Fluke Water-Resistant Multimeters

For taking electrical measurements in washdown environments, choose the durability and quality of a Fluke multimeter with an IP67-rated housing.
True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
Multimeters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | ||||||||||||
28 II | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | 000000 | 0000000 |
Multimeters with Calibration Certificate | ||||||||||||
True RMS AC Calculation | ||||||||||||
28 II | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | 00000000 | 000000 |
Fluke Clamp-On Multimeters

Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Manufacturer Model Number | Jaw Opening | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Display Count | Includes | Each | |
Multimeters | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||
324 | 1.18" | CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature | 600 | 600 | 1% | 400 | 6,000 | Carrying Case, Temperature Probe, Test Leads | 00000000 | 0000000 |
Multimeters with Calibration Certificate | |||||||||||
True RMS AC Calculation | |||||||||||
324 | 1.18" | CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature | 600 | 600 | 1% | 400 | 6,000 | Carrying Case, Temperature Probe, Test Leads | 00000000 | 000000 |
Fluke Test Sensors
Take temperature readings with a Fluke multimeter.
Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.


Manufacturer Model Number | For Fluke Model Number | Temperature Range, ° F | AC Voltage | DC Voltage | Test End | Connection End | Cord Lg. | Test End Insulation Material | Each | |
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40° to 500° | __ | __ | Needle Tip | Sheathed Banana Jack | 39" | PTFE | 0000000 | 000000 |
80TK | 27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789 | -40° to 500° | 24 | 60 | Needle Tip | Sheathed Banana Plug | 39" | PTFE | 0000000 | 000000 |
Fluke Scopemeters

Perform electrical tests, record data, and see a graph of electrical waveforms with this combination multimeter and oscilloscope. Fluke scopemeters are known for quality and durability.
To download and analyze data on a computer, software is required (not included).
When used as an oscilloscope, the scopemeter is most accurate when the frequency is at least five times the maximum signal frequency you intend to measure.
The multimeter function is true RMS, so it accurately takes AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. This 5,000-count scopemeter shows numbers up to 4,999.
Manufacturer Model Number | No. of Digital Channels | Frequency | Safety Rating | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Display Count | Data Log Capacity | Includes | Specifications Met | Measures | Batteries Included | Each | |
True RMS AC Calculation | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
123B | 2 | 0-20 MHz | CAT IV, 600V | 600 | 600 | 0.5% | 5,000 | 512 | Alligator Clips, Battery Charger, BNC Adapter, Probe Tips, Test Leads | CSA Certified | AC Voltage, Capacitance, Continuity, DC Voltage, Temperature | Yes | 0000000 | 000000000 |