McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    28 Products

    Submersible Pumps for Water

    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style A.
    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style B.
    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style C.

    Style A

    Style B

    Style C

    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style D.
    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style E.

    Style D

    Style E

    Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
    Style A
    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style A.
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    2.81.7735 to 1201/1250.6Screened1/4
    NPT
    Male63 5/8"2 7/8"3 1/2"4182K220000000
    542.212.235 to 1201/400.8Screened1/4
    NPT
    Male64 1/4"2 7/8"4 7/8"4182K36000000
     
    Style B
    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style B.
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    115V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    5.64.30.811.135 to 851/150.8Screened1/4
    NPT
    Male64"3 7/8"5 3/8"3163K33000000
    8.96.92.51335 to 851/101.2Screened1/2
    NPT
    Male64 1/2"4"5 5/8"3163K3400000
     
    115V AC, Single Phase—Without Thermal Overload Protection
     
    Plug In
    3.51.57.135 to 851/250.5Screened1/4
    NPT
    Male63 7/8"3 1/2"4 5/8"3163K3200000
     
    Style C
    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style C.
    Hardwire—Hardwire pumps must be wired to a plug (not included).
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    3.52.510.235 to 1201/1501.1Screened1/4
    NPT
    Male64 5/8"4 1/8"4 1/8"9988K760000000
    5.44.52.212.335 to 1201/401.7Screened1/4
    NPT
    Male64 5/8"5"5"9988K86000000
    5.44.52.212.335 to 1201/401.7Screened1/4
    NPT
    Male184 5/8"5"5"9988K89000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    5.44.52.212.335 to 1201/400.7Screened1/4
    NPT
    Male124 5/8"5"5"9988K96000000
     
    Style D
    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style D.
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    7.96.63.413.435 to 1201/281.4Screened3/8
    NPT
    Male64"4"4 5/8"4182K370000000
     
    Style E
    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Water, Style E.
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    115V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    201241535 to 851/151Screened3/4
    NPT
    Male155 1/4"3 3/4"6 3/8"3163K3110000000
     

    Impact-Resistant Submersible/Open-Air Pumps for Water

    Image of Product. Front orientation. Submersible Pumps. Impact-Resistant Submersible/Open-Air Pumps for Water, Style A.
    Image of Product. Front orientation. Submersible Pumps. Impact-Resistant Submersible/Open-Air Pumps for Water, Style B.

    Style A

    Style B

    Protected from impact by a durable epoxy-coated aluminum housing, these pumps can be submerged or connected remotely to a pipe in your line. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
    Style A
    Image of Product. Front orientation. Submersible Pumps. Impact-Resistant Submersible/Open-Air Pumps for Water, Style A.
    Max. Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    3.427.435 to 1201/1501.11/4 × 1/2NPT × NPTFemale × Male1/4
    NPT
    Male64 1/8"4 1/8"4 5/8"4182K260000000
     
    Style B
    Image of Product. Front orientation. Submersible Pumps. Impact-Resistant Submersible/Open-Air Pumps for Water, Style B.
    Hardwire—Hardwire pumps must be wired to a plug (not included).
    Max. Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Features
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    53.41.211.835 to 1201/401.73/8
    NPT
    Female1/4
    NPT
    Male64 3/4"3 1/2"5 1/2"Removable Intake Screen4182K30000000
    8.35.63.517.335 to 1201/153.21/2
    NPT
    Female1/2
    NPT
    Male65 1/2"4 1/2"7"Removable Intake Screen4182K4000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    53.41.211.835 to 1201/400.73/8
    NPT
    Female1/4
    NPT
    Male124 3/4"3 1/2"5 1/2"Removable Intake Screen4182K73000000
    108.66.92135 to 1201/151.41/2
    NPT
    Female1/2
    NPT
    Male125 1/2"4 1/2"7"Removable Intake Screen4182K17000000
     

    Long-Life Submersible/Open-Air Pumps for Water

    These pumps can be submerged or connected remotely to a pipe in your line. Magnets turn the impeller so there's no shaft seal to wear out. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
    Tube
    Image of Product. Front orientation. Submersible Pumps. Long-Life Submersible/Open-Air Pumps for Water.
    Max. Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    Electrical
    Connection Type
    @ 0 Ft.
    of Head
    @ 1 Ft.
    of Head
    @ 3 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Removes
    Water Down To
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    For Tube
    ID
    Gender
    Connection
    For Tube
    ID
    Gender
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—Without Thermal Overload Protection
    Plug In2.321.54.63"35 to 1601/2000.5Barbed
    3/8"MaleBarbed
    3/8"Male3 1/4"3 3/4"4 1/2"9971K210000000
    Plug In32.61.84.63"35 to 1601/2000.5Barbed
    1/2"MaleBarbed
    1/2"Male3 1/4"3 3/4"4 1/2"9971K11000000
     
    Pipe
    Image of Product. Front orientation. Submersible Pumps. Long-Life Submersible/Open-Air Pumps for Water.
    Max. Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    Electrical
    Connection Type
    @ 0 Ft.
    of Head
    @ 1 Ft.
    of Head
    @ 3 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Removes
    Water Down To
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Pipe
    Size
    Thread
    Type
    Gender
    Connection
    Pipe
    Size
    Thread
    Type
    Gender
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—Without Thermal Overload Protection
    Plug In32.61.84.63"35 to 1601/2000.5Threaded1/4
    NPT
    MaleThreaded1/4
    NPT
    Male3 1/4"3 3/4"4 1/2"9971K310000000
     

    Impact-Resistant Submersible Pumps for Water

    Image of Product. Front orientation. Submersible Pumps. Impact-Resistant Submersible Pumps for Water, Style A.
    Image of Product. Front orientation. Submersible Pumps. Impact-Resistant Submersible Pumps for Water, Style B.

    Style A

    Style B

    The durable epoxy-coated aluminum housing handles hard knocks in rough waters. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
    Style A
    Image of Product. Front orientation. Submersible Pumps. Impact-Resistant Submersible Pumps for Water, Style A.
    Hardwire—Hardwire pumps must be wired to a plug (not included).
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    2.81.7735 to 1201/2001.1Screened1/4
    NPT
    Male64 1/4"4 1/8"4 1/8"4182K240000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    3.427.435 to 1201/1500.4Screened1/4
    NPT
    Male124 1/4"4 1/8"4 1/8"4182K72000000
     
    Style B
    Image of Product. Front orientation. Submersible Pumps. Impact-Resistant Submersible Pumps for Water, Style B.
    Hardwire—Hardwire pumps must be wired to a plug (not included).
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    53.41.211.835 to 1201/401.7Screened1/4
    NPT
    Male64 3/4"3 1/2"5 1/2"4182K20000000
    13.512.410.224.535 to 1201/123.5Screened1/2
    NPT
    Male65 1/2"4 1/2"7"4182K5000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    13.512.410.224.535 to 1201/121.6Screened1/2
    NPT
    Male125 1/2"4 1/2"7"4182K74000000
     

    Submersible/Open-Air Pumps for Water

    Image of Product. Front orientation. Submersible Pumps. Submersible/Open-Air Pumps for Water.
    These pumps can be submerged or connected remotely to a pipe in your line. Use them to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
    Max. Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    2.81.7735 to 1201/1250.61/4 × 1/2NPT × NPTFemale × Male1/4
    NPT
    Male103 3/8"3 3/4"2 3/4"4182K250000000
     

    Long-Life Submersible Pumps for Water

    Image of Product. Front orientation. Submersible Pumps. Long-Life Submersible Pumps for Water.
    Magnets turn the impeller so there's no shaft seal to wear out. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 0 Ft.
    of Head
    @ 1 Ft.
    of Head
    @ 3 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Removes
    Water Down To
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Certification
    Each
    120V AC, Single Phase—Without Thermal Overload Protection
     
    Plug In
    32.61.84.63"35 to 1601/2000.5Screened1/4
    NPT
    Male63 1/4"3 3/4"3 7/8"UL Recognized Component
    9971K410000000
     

    Submersible Pumps for Salt Water

    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Salt Water.
    Circulate salt water in submerged and open-air applications. These pumps use magnets to turn the impellers so there is no shaft seal to wear out. They must be wired to a plug (not included) to activate. Do not run dry.
    Max. Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    53.81335 to 1301/500.93/8 × 3/4NPT × NPTFemale × Male1/4
    NPT
    Male64 1/8"6 1/8"4 7/8"99845K460000000
    8.581935 to 1301/2023/4
    NPT
    Female1/2
    NPT
    Male64 7/8"7 3/8"4 3/4"99845K48000000
     
    back to top