    15 Products

    Wall-Mount Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Wall-Mount Fume Exhausters.
    Remove fumes, vapors, and fine dust particles from your space. This exhauster is commonly used in welding, soldering, and other operations that create fumes.
    Open Dripproof (ODP) Motor Enclosure—Use open dripproof exhausters in relatively clean, dry, well-ventilated indoor locations.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC—Hardwire
    300 ft³/min @ 1/2 in. H₂O61 dBC @ 15 ft.1/44"4"16"16"8 7/8"Galvanized SteelSteelSteelNo1/4"
    9/32"40000000000000
     

    Wall-Mount Hazardous-Location Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Wall-Mount Hazardous-Location Fume Exhausters.
    This fume exhauster has a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G locations. Use it to remove fumes, vapors, and fine dust particles from your space. It is commonly used in welding, soldering, and other operations that create fumes.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Hazardous Location Rating
    Each
     
    120V AC—Hardwire
    300 ft³/min @ 1/2 in. H₂O61 dBC @ 15 ft.1/44"4"16"17 5/8"8 7/8"Galvanized SteelSteelAluminum
    No1/4"
    9/32"4NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    000000000000000
     

    Portable Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Portable Fume Exhausters.
    In addition to using the handle to carry these exhausters, you can mount them to a wall, bench, or floor. They remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments. They have a flexible hose with nozzle to capture fumes at the source and rubber pads on the base to reduce vibration.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Nozzle
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Housing
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Hose Lg.,
    ft.
    Each
    Totally Enclosed Motor Enclosure
     
    120V AC, Single Phase—Plug In
    280 ft³/min @ 1 1/2 in. H₂O
    330 ft³/min @ 1/4 in. H₂O
    345 ft³/min @ 0 in. H₂O
    62 dBA @ 15 ft.1/24"4"18 3/4"17 1/2"16"4"8"SteelAluminum
    No3/8"
    7/16"4100000000000000000
     
    230V AC/460V AC, Three Phase—Hardwire
    280 ft³/min @ 1 1/2 in. H₂O
    330 ft³/min @ 1/4 in. H₂O
    345 ft³/min @ 0 in. H₂O
    62 dBA @ 15 ft.1/24"4"18 3/4"17 1/2"16"4"8"SteelAluminum
    No3/8"
    7/16"410000000000000000
     
    Duct Kits

    DC Blowers

    Operate these blowers with a DC power source, such as your vehicle battery. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. DC Blowers.
    Blowers with a totally enclosed motor enclosure can be used in dirty, dusty, and wet environments.
    Multidirection Mounting Bracket—Blowers with a multidirection mounting bracket can be rotated to discharge air in any direction.
    Overall
    Temp.
    Mounting
    Airflow @ SP
    Volume (Sound),
    dB
    Motor Speed,
    rpm
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Min.
    Max.,
    ° F
    Fasteners
    Included
    Hole
    Dia.
    Includes
    Each
    12V DC
     
    Hardwire
    250 ft³/min @ 0 in. H₂O662,5004"4"4"9 5/8"9 1/4"8 3/4"Not Rated130No1/4"Multidirection Mounting Bracket00000000000000
     
    24V DC
     
    Hardwire
    250 ft³/min @ 0 in. H₂O702,5004"4"4"9 5/8"9 1/4"8 3/4"Not Rated130No1/4"Multidirection Mounting Bracket0000000000000
     

    High-Output Hazardous Location Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard hazardous location spark-resistant blowers can handle. They have an explosion-proof motor that is UL listed for hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. High-Output Hazardous Location Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    130 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/34"4"7"13 5/8"14 3/4"12 1/8"567.0 amp/3.5 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"0000000000000000
    250 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/24"4"8 1/8"13 5/8"14 3/4"12 1/8"497.4 amp/3.7 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"000000000000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    130 ft³/min @ 3 in. H₂O64 dBA @ 15 ft.3,4501/34"4"7"13 7/16"11 3/8"17 1/4"571.0 amp/0.5 amp-10 to 150AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    No7/16"0000000000000000
    250 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/24"4"8 1/8"13 5/8"14 3/4"12 1/8"472.2 amp/1.1 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"000000000000000
     

    High-Output Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard spark-resistant blowers can handle. They have an aluminum housing for spark resistance. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    130 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/34"4"7"13 5/8"14 3/4"12 1/8"415.6 amp/2.8 amp0 to 100AluminumNo7/16"0000000000000000
    250 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/24"4"8 1/8"13 5/8"14 3/4"12 1/8"487.2 amp/3.6 amp0 to 100AluminumNo7/16"000000000000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    130 ft³/min @ 3 in. H₂O64 dBA @ 15 ft.3,4501/34"4"7"13 7/16"11 3/8"11 3/8"571.2 amp/0.6 amp-10 to 150AluminumNo7/16"000000000000000
    250 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/24"4"8 1/8"13 5/8"14 3/4"12 1/8"401.8 amp/0.9 amp0 to 100AluminumNo7/16"000000000000000
     