Don’t see the fuse you need? Just tell us what you’re looking for and we’ll get it for you.
About Fuses
More
UL Class CC Time-Delay Midget Fuses for Motors

These fuses can withstand the high inrush current caused by a motor starting. They provide comparable performance with a smaller footprint than standard size fuses. All have a rejection-style end that safeguards against replacement errors. Use them to protect power distribution branch circuits. Designed for use with Fuse Blocks for UL Class CC Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | Each | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Specifications Met | 1-9 | 10-Up | |
Manufacturer Equivalent: ATD-R, CCMR, LP-CC | ||||||||||
8/10 | 600V AC/300V DC | 100,000 A @ 300 V DC 200,000 A @ 600 V AC | 1 1/2" | 13/32" | 1 | Ferrule | UL Listed | 000000000 | 000000 | 000000 |
UL Class CC Time-Delay Midget Fuses for Transformers

Designed to handle high inrush currents and the initial current cycle unique to transformers, these fuses provide comparable performance with a smaller footprint than standard size fuses. Use them to protect power distribution branch circuits. They’re for use with Fuse Blocks for UL Class CC Fuses.
Fuses with a rejection-style end safeguard against replacement errors.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | Each | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Rejection-Style End | Specifications Met | 1-9 | 10-Up | |
Manufacturer Equivalent: ATQ-R, FNQ-R, KLD-R | |||||||||||
8/10 | 600V AC | 200,000 A @ 600 V AC | 1 1/2" | 13/32" | 1 | Ferrule | Yes | UL Listed | 0000000 | 000000 | 000000 |
Fast-Acting Glass-Tube Fuses

These fuses open circuits quickly when surges are detected. The clear glass tube makes it easy to see when fuses open. Use them with electronics, control panels, and other sensitive components. Select them by their diameter. Designed for use with Fuse Blocks for Glass-Tube Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Pkg. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Overall Lg. | No. of Elements | Blown Fuse Indicator | Specifications Met | Pkg. Qty. | 1-9 | 10-Up | |
Manufacturer Equivalent: 217, GDB, GSB | ||||||||||
5mm Overall Dia. | ||||||||||
8/10 | 250V AC | 35 A @ 250 V AC | 20mm | 1 | Yes | UL Recognized Component, CSA Certified | 5 | 00000000 | 00000 | 00000 |
Time-Delay Glass-Tube Fuses

Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges. The clear glass tube makes it easy to see when fuses open. Use them with electronics, control panels, and other sensitive components. Select these fuses by their diameters. Designed for use with Fuse Blocks for Glass-Tube Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Pkg. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Overall Lg. | No. of Elements | Blown Fuse Indicator | Specifications Met | Pkg. Qty. | 1-9 | 10-Up | |
Manufacturer Equivalent: 218, GDC, GDG | ||||||||||
5mm Overall Dia. | ||||||||||
8/10 | 250V AC | 35 A @ 250 V AC | 20mm | 1 | Yes | UL Recognized Component, CSA Certified, IEC 60127-2 | 5 | 00000000 | 000000 | 00000 |
Time-Delay Ceramic-Tube Fuses

Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges. They can withstand temperature swings and high ambient temperatures better than glass-tube fuses. Use them with electronics, control panels, and other sensitive components. Select these fuses by their diameters. Designed for use with Fuse Blocks for Ceramic-Tube Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Pkg. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Overall Lg., mm | No. of Elements | Specifications Met | Pkg. Qty. | 1-9 | 10-Up | |
Manufacturer Equivalent: 215, GSF, S505 | |||||||||
5mm Overall Dia. | |||||||||
8/10 | 250V AC | 100 A @ 250 V AC | 20 | 1 | UL Recognized Component, CSA Certified, CE Marked | 5 | 00000000 | 000000 | 000000 |
Manufacturer Equivalent: 477 | |||||||||
5mm Overall Dia. | |||||||||
8/10 | 500V AC/400V DC | 100 A @ 500 V AC 400 A @ 400 V DC | 20 | 1 | UL Recognized Component, C-UL Recognized Component, CE Marked | 5 | 00000000 | 00000 | 00000 |
Fast-Acting Ceramic-Tube Fuses

These fuses open circuits quickly when surges are detected. They can withstand temperature swings and high ambient temperatures better than glass-tube fuses. Use with electronics, control panels, and other sensitive components. Select these fuses by their diameters. Designed for use with Fuse Blocks for Ceramic-Tube Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Pkg. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Overall Lg. | No. of Elements | Specifications Met | Pkg. Qty. | 1-9 | 10-Up | |
Manufacturer Equivalent: 216, GDA, GSD | |||||||||
5mm Overall Dia. | |||||||||
8/10 | 250V AC | 1,500 A @ 250 V AC | 20mm | 1 | UL Recognized Component | 5 | 00000000 | 000000 | 000000 |
Time-Delay Midget Fuses

Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges, such as when starting a motor. Use them to protect equipment—they are not designed for power distribution circuits. Designed for use with Fuse Blocks for Midget Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | Each | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Specifications Met | 1-9 | 10-Up | |
Manufacturer Equivalent: ATQ, FLQ, FNQ | ||||||||||
8/10 | 500V AC | 10,000 A @ 500 V AC | 1 1/2" | 13/32" | 1 | Ferrule | UL Listed, CSA Certified | 0000000 | 000000 | 000000 |
Manufacturer Equivalent: FLM, FNM, TRM | ||||||||||