About Fuses
More
UL Class RK5 Fuses


Also known as dual-element fuses, these time-delay fuses withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor. They have a rejection-style end design that safeguards against replacement errors. Use with Fuse Blocks for UL Class RK5 Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
Fuses with blown fuse indicator have a dot on the side that changes color when the fuse blows.
Overall | Each | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Blown Fuse Indicator | Specifications Met | UL File Number | CSA File Number | 1-9 | 10-Up | |
Manufacturer Equivalent: FLN-R, FRN-R, TR-R | |||||||||||||
90 | 250V AC | 200,000 A @ 250 V AC | 5 7/8" | 1 1/16" | 2 | Knife Blade | No | UL Listed, CSA Certified | E4273 | 053787_C_000 | 0000000 | 000000 | 000000 |
Manufacturer Equivalent: FLN-R-ID, FRN-R-ID, TR-R-ID | |||||||||||||
90 | 250V DC/250V AC | 20,000 A @ 250 V DC 200,000 A @ 250 V AC | 5 7/8" | 1 1/16" | 2 | Knife Blade | Yes | UL Listed, CSA Certified | E2137 | 012636_0_000 | 00000000 | 00000 | 00000 |
Manufacturer Equivalent: FLS-R, FRS-R, TRS-R | |||||||||||||
90 | 600V AC/300V DC | 20,000 A @ 300 V DC 200,000 A @ 600 V AC | 7 7/8" | 1 1/8" | 2 | Knife Blade | No | UL Listed, CSA Certified | E4273 | 053787_C_000 | 00000000 | 00000 | 00000 |
Manufacturer Equivalent: FRS-R-ID, IDSR, TRS-R-ID | |||||||||||||
90 | 600V DC/600V AC | 20,000 A @ 600 V DC 200,000 A @ 600 V AC | 7 7/8" | 1 5/16" | 2 | Knife Blade | Yes | UL Listed, CSA Certified | E2137 | 012636_0_000 | 00000000 | 00000 | 00000 |
UL Class J Time-Delay Fuses for Tight Spaces


Also known as dual-element fuses, these fuses withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor. More compact than UL Class RK1 or RK5 fuses, they are suitable for tight spaces. Use with Fuse Blocks for UL Class J Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
Fuses with blown fuse indicator have a dot on the side that changes color when the fuse blows.
For technical drawings and 3-D models, click on a part number.
Overall | Each | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Blown Fuse Indicator | Specifications Met | 1-9 | 10-Up | |
Manufacturer Equivalent: AJT, JTD, LPJ-SP | |||||||||||
90 | 600V AC/300V DC | 100,000 A @ 300 V DC 300,000 A @ 600 V AC | 4 5/8" | 1 1/8" | 2 | Knife Blade | No | UL Listed, CSA Certified | 000000000 | 0000000 | 000000 |
Manufacturer Equivalent: AJT, JTD-ID, LPJ-SPI | |||||||||||
90 | 600V AC/400V DC | 100,000 A @ 400 V DC 200,000 A @ 600 V AC | 4 5/8" | 1 1/16" | 2 | Knife Blade | Yes | UL Listed, CSA Certified | 0000000 | 00000 | 00000 |
UL Class RK1 Fast-Acting Fuses

These fuses open circuits quickly when surges are detected. They have a rejection-style end design that safeguards against replacement errors. Use with Fuse Blocks for UL Class RK1 Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | Each | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Specifications Met | 1-9 | 10-Up | |
Manufacturer Equivalent: A6K-R, KLS-R, KTS-R | ||||||||||
90 | 600V AC/300V DC | 20,000 A @ 300 V DC 200,000 A @ 600 V AC | 7 7/8" | 1 5/16" | 1 | Knife Blade | UL Listed, CSA Certified | 00000000 | 0000000 | 0000000 |
UL Class T Fuses for Extra-Tight Spaces

Smaller than UL Class J fuses, these fast-acting fuses can be used in extra-tight spaces such as meters, uninterruptible power supplies, and variable-speed drives. They open circuits quickly when surges are detected. Use with Fuse Blocks for UL Class T Fuses.
Breakthrough current, also known as interrupt current, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | Each | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Specifications Met | 1-9 | 10-Up | |
Manufacturer Equivalent: A6T, JJS, JLLS | ||||||||||
90 | 600V AC | 200,000 A @ 600 V AC | 2 15/16" | 3/4" | 1 | Knife Blade | UL Listed, CSA Certified, CE Marked | 000000000 | 000000 | 000000 |
Fast-Acting Lift Truck Fuses

These fuses open circuits quickly when surges are detected. Use them on battery-operated lift trucks.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
Fuses with blown fuse indicator have a dot on the side that changes color when the fuse blows.
For technical drawings and 3-D models, click on a part number.
Touch-Safe Fuses

Prevent accidental contact with electrical circuits—these fuses have an enclosed design with recessed plug-in blades. Also known as dual-element fuses, they withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
Fuses with blown fuse indicator have a dot on the side that turns red when the fuse blows.
For technical drawings and 3-D models, click on a part number.
Fuses | DIN-Rail Mount Fuse Blocks | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | UL Class | Voltage | Breakthrough Current | Ht. | Wd. | Dp. | No. of Elements | Blown Fuse Indicator | Protection Type | Specifications Met | Each | Each | ||
Manufacturer Equivalent: TCF | ||||||||||||||
90 | CF | 600V AC/300V DC | 100,000 A @ 300 V DC 300,000 A @ 600 V AC | 3.01" | 1" | 1.26" | 2 | Yes | Time Delay | UL Listed, CSA Certified, EN 63000, IEC 63000 | 0000000 | 0000000 | 0000000 | 000000 |