McMaster-Carr logo
    Filter by
    Conduit Trade Size
    Industrial Info Compare
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    12 Products
    About Conduit
    industrial info icon

    Compare rigid and flexible conduit materials and identify the trade size for compatible fittings.

    Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings.
    The industry standards, IMC and RMC conduit systems offer the most durable protection indoors, outdoors, and underground. Both types have the same outside diameter, so they use many of the same fittings. This interchangeability makes retrofits easier and reduces the parts you need to keep on hand.
    Conduit
    Image of Product. Front orientation. Conduit and Fittings. Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings, Conduit .
    Run wiring through conduit to route and protect it.
    Galvanized Steel—Strong and resists rust and mild chemicals.
    RMC—The choice when you need maximum impact and crush resistance. The thickest and heaviest conduit option, it’s often found in older installations or used as structural support.
    10 ft. Long
    Conduit
    Trade Size
    Thread
    Type
    Conduit
    Type
    Specs.
    Met
    Each
    Galvanized Steel
    1/2
    NPT
    RMC
    UL Listed
    7307K21000000
    3/4
    NPT
    RMC
    UL Listed
    7307K2200000
    1
    NPT
    RMC
    UL Listed
    7307K2300000
    1 1/4
    NPT
    RMC
    UL Listed
    7307K24000000
    1 1/2
    NPT
    RMC
    UL Listed
    7307K25000000
    2
    NPT
    RMC
    UL Listed
    7307K26000000
     
    Grounding Clamps
    Image of Product. Front orientation. Grounding Clamps.
    Prevent conduit from becoming a shock hazard by running a ground wire through the attached lug to redirect current. The included grommet protects wire and cable from abrasion when being pulled.
    Conduit
    Trade Size
    Thread
    Type
    Gender
    Material
    For Use With
    Features
    Specs. Met
    Each
    1/2
    NPSM
    FemaleZincAluminum Wire, Copper WireUL Listed, ANSI/NEMA FB 17513K251000000
    3/4
    FemaleZincAluminum Wire, Copper WireHingeUL Listed, ANSI/NEMA FB 17513K25200000
    1
    FemaleZincAluminum Wire, Copper WireHingeUL Listed, ANSI/NEMA FB 17513K25300000
    1 1/4
    FemaleZincAluminum Wire, Copper WireHingeUL Listed, ANSI/NEMA FB 17513K25400000
    1 1/2
    FemaleZincAluminum Wire, Copper WireHingeUL Listed, ANSI/NEMA FB 17513K25500000
    2
    FemaleZincAluminum Wire, Copper WireHingeUL Listed, ANSI/NEMA FB 17513K25600000
    back to top