About Sump, Water-Removal, Condensate, and Submersible Pumps
More
About Process Pumps
More
Miniature Water-Removal Pumps with Hose

Complete with a suction strainer and 6 feet of garden hose, this little pump comes ready to clean up small open spaces. It activates when you plug it in. Use with debris-free water.
Maintenance kits (sold separately) include an impeller, an O-ring, and a seal.
Note: The pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Thread Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 6 ft. Cord | |||||||||||||||||||
5.5 | 5 | 4.5 | 4 | 43 | 1/8" | 35° to 75° | 1/12 hp | 2 | 3/4 | GHT | Male | 3/4 | GHT | Male | 6" | 5" | 7" | 0000000 | 0000000 |
Maintenance Kit | 0000000 | Each | 000000 |
Harsh-Environment Self-Priming Water-Removal Pumps

This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Intake Size | Discharge Size | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||
Plug with 8 ft. Cord | |||||||||||||
5 4/5 | 30 | 1/4" | 125 | 60° to 180° | 1/4 hp | 4.2 | 1/2 NPT Female, 3/4 GHT Male | 1/2 NPT Female, 3/4 GHT Male | 9" | 5 5/8" | 7 3/8" | 0000000 | 0000000 |
Battery-Operated Water-Removal Pumps

Remove water in locations without power with these battery-operated pumps. They attach to an 18-volt battery. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Intake | Discharge | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 Ft. of Head, gpm | Max. Ft. of Head, ft. | Temp. Range, °F | Thread Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
8 | 75 | 35° to 140° | 3/4 | GHT | Male | 3/4 | GHT | Male | 6" | 5 3/4" | 13 1/4" | 0000000 | 0000000 |
Water Removal Pumps with Hose

Use this pump to remove water with small solids up to 1/4" in diameter. It activates when plugged in; add a plug-in switch to control when the pump activates. Install in water that's at least 2" deep. Pump includes a 25-ft. hose with cam-and-groove fittings for quick, secure connections and a storage crate with built-in filtration to protect the pump from debris.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Flow Rate | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Connection Coupling Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug with 15" Cord | |||||||||||||||||
41 | 32 | 23 | 11 | 41 gpm | 25 | 1/4" | 7/16" | 35° to 100° | 4/10 hp | 3 | 1 1/4 | Male | 12 3/4" | 11 13/16" | 15 3/4" | 0000000 | 0000000 |
Drill-Operated Water-Removal Pumps



Convenient to keep in your toolkit for on-site cleanup, these pumps attach to your drill for small liquid extraction jobs, as well as draining water from clogged sinks and emptying tanks. Pumps are self-priming, which means they create a suction force to draw liquid upward. Do not use with solids.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Intake | Discharge | Shaft | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Feet of Head, ft. | Max. Viscosity, cP | Temp. Range, °F | Hose Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Motor Speed, rpm | Dia. | Lg. | Ht. | Wd. | Lg. | Includes | Each | |
3 3/4 | 90 | 1 | 40° to 110° | 3/4 | GHT | Male | 3/4 | GHT | Male | 1,200 | 1/4" | 3/4" | 3" | 4 1/2" | 3" | __ | 00000000 | 000000 |
3 3/4 | 90 | 1 | 40° to 110° | 3/4 | GHT | Male | 3/4 | GHT | Male | 1,200 | 1/4" | 3/4" | 3" | 4 1/2" | 3" | 30" Slip-On Intake Tube, 34" Discharge Tube with 3/4" Male GHT Connection | 00000000 | 00000 |
Hand-Operated Water-Removal Pumps

Install these pumps right in your line and engage the lever handle to start pumping. They have few moving parts that can fail for an extended service life. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, oz./stroke | Max. Ft. of Head, ft. | Max. Viscosity, cP | Max. Solids Dia. | Temp. Range, °F | For Hose ID | Hose Connection Type | Gender | For Hose ID | Hose Connection Type | Gender | Ht. | Wd. | Lg. | Each | |
14 | 35 | 100,000 | 1/8" | 35° to 150° | 1" | Barbed | Male | 1" | Barbed | Male | 4 3/8" | 4 3/8" | 12 3/4" | 0000000 | 000000 |
17 | 35 | 100,000 | 1/8" | 35° to 150° | 1 1/2" | Barbed | Male | 1 1/2" | Barbed | Male | 4 1/4" | 4 3/8" | 13 1/8" | 0000000 | 000000 |