Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, cfh | Inlet Pipe Size | Inlet Thread Type | Inlet Gender | Tube Connection Type | Thread Type | For Tube OD | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Each | |
Natural Gas Heaters with Knob | ||||||||||||||||||
Pilot Light Ignition | ||||||||||||||||||
A | 100,000 | 13,300 cu. ft. @ 10° F 6,600 cu. ft. @ 20° F 4,400 cu. ft. @ 30° F 3,300 cu. ft. @ 40° F | Not Rated | 100 | __ | __ | Male | 37° Flared | UN/UNF (JIC) | 1/2" | __ | __ | 19" | 16" | 16" | Steel | 0000000 | 0000000 |
Natural Gas Heaters with Thermostat (40° to 105° F) | ||||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | ||||||||||||||||||
B | 155,000 | 20,660 cu. ft. @ 10° F 10,330 cu. ft. @ 20° F 6,880 cu. ft. @ 30° F 5,160 cu. ft. @ 40° F | 625 | 155 | 1/2 | NPT | Female | __ | __ | __ | 2.1 | 4" | 16" | 9" | 24" | Steel | 0000000 | 000000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Inlet Thread Type | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Includes | Each | |
Propane Heaters with Knob | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | Not Rated | 20 | 4 | NGO | __ | __ | 16" | 19" | 22" | Steel | 20-ft. Hose | 0000000 | 0000000 |
A | 200,000 | 26,660 cu. ft. @ 10° F 13,330 cu. ft. @ 20° F 8,880 cu. ft. @ 30° F 6,660 cu. ft. @ 40° F | Not Rated | 100 | 9.5 | NGO | __ | __ | 19" | 15" | 28" | Steel | 20-ft. Hose | 0000000 | 000000 |
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
B | 125,000 | 16,660 cu. ft. @ 10° F 8,330 cu. ft. @ 20° F 5,550 cu. ft. @ 30° F 4,160 cu. ft. @ 40° F | 400 | 100 | 6 | NGO | 0.7 | 10" | 16" | 12" | 26" | Steel | 15-ft. Hose | 0000000 | 000000 |
Propane Heaters with Thermostat (40° to 105° F) | |||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
B | 170,000 | 22,660 cu. ft. @ 10° F 11,330 cu. ft. @ 20° F 7,550 cu. ft. @ 30° F 5,660 cu. ft. @ 40° F | 625 | 100 | 8 | NGO | 2.1 | 4" | 16" | 9" | 24" | Steel | 10-ft. Hose | 0000000 | 000000 |
B | 400,000 | 53,330 cu. ft. @ 10° F 26,660 cu. ft. @ 20° F 17,770 cu. ft. @ 30° F 13,330 cu. ft. @ 40° F | 1,580 | 500 | 18.5 | NGO | 1.5 | 4" | 22" | 13" | 35" | Steel | 10-ft. Hose | 0000000 | 000000 |
Replacement Air Filter for 125,000 and 170,000 Btu/hr. Heaters | 0000000 | Each | 000000 |
Ceiling-Mount Large-Space Gas Heaters


Heat shops, garages, warehouses, and other large spaces with these heaters that can be suspended from the ceiling. They have an electronic spark ignition that makes them good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Note: Heaters need to be vented to the outdoors. Vent pipe is not included.
Use with low-voltage thermostat (sold separately).
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Mounting Brackets | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Current, A | Max. Mounting Ht., ft. | Ht. | Wd. | Dp. | Required Vent Dia. | Includes | Each | Pair | |||
Natural Gas Heaters | |||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase (Wire Leads) | |||||||||||||||||
A | 36,000 | 4,800 cu. ft. @ 10° F 2,400 cu. ft. @ 20° F 1,600 cu. ft. @ 30° F 1,200 cu. ft. @ 40° F | 720 | 1/2 | NPT | Female | 3.7 | 10 | 13" | 27" | 22" | 3" | Mounting Bracket | 00000000 | 000000000 | 000000 | 00 |
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | 1,490 | 1/2 | NPT | Female | 4.7 | 12 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 0000000 |
A | 100,000 | 13,330 cu. ft. @ 10° F 6,660 cu. ft. @ 20° F 4,440 cu. ft. @ 30° F 3,330 cu. ft. @ 40° F | 1,980 | 1/2 | NPT | Female | 4.2 | 16 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 000000 |
B | 200,000 | 26,660 cu. ft. @ 10° F 13,330 cu. ft. @ 20° F 8,880 cu. ft. @ 30° F 6,660 cu. ft. @ 40° F | 3,700 | 1/2 | NPT | Female | 7.7 | 19 | 41" | 26" | 35" | 6" | __ | 00000000 | 00000000 | 000000 | 00 |
B | 320,000 | 42,660 cu. ft. @ 10° F 21,330 cu. ft. @ 20° F 14,220 cu. ft. @ 30° F 10,660 cu. ft. @ 40° F | 5,440 | 3/4 | NPT | Female | 11.1 | 19 | 41" | 40" | 39" | 6" | __ | 00000000 | 00000000 | 000000 | 00 |
Propane Heaters | |||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase (Wire Leads) | |||||||||||||||||
A | 36,000 | 4,800 cu. ft. @ 10° F 2,400 cu. ft. @ 20° F 1,600 cu. ft. @ 30° F 1,200 cu. ft. @ 40° F | 720 | 1/2 | NPT | Female | 3.7 | 10 | 13" | 27" | 22" | 3" | Mounting Bracket | 00000000 | 00000000 | 000000 | 00 |
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | 1,490 | 1/2 | NPT | Female | 4.7 | 12 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 000000 |
A | 100,000 | 13,330 cu. ft. @ 10° F 6,660 cu. ft. @ 20° F 4,440 cu. ft. @ 30° F 3,330 cu. ft. @ 40° F | 1,980 | 1/2 | NPT | Female | 4.2 | 16 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 000000 |
B | 200,000 | 26,660 cu. ft. @ 10° F 13,330 cu. ft. @ 20° F 8,880 cu. ft. @ 30° F 6,660 cu. ft. @ 40° F | 3,700 | 1/2 | NPT | Female | 7.7 | 19 | 41" | 26" | 35" | 6" | __ | 00000000 | 00000000 | 000000 | 00 |
B | 320,000 | 42,660 cu. ft. @ 10° F 21,330 cu. ft. @ 20° F 14,220 cu. ft. @ 30° F 10,660 cu. ft. @ 40° F | 5,440 | 3/4 | NPT | Female | 11.1 | 19 | 41" | 40" | 39" | 6" | __ | 00000000 | 00000000 | 000000 | 00 |
Low-Voltage Thermostat | 00000000 | Each | 000000 |
Mobile Large-Space Kerosene and Diesel Heaters



Roll these powerful space heaters to where you need heat for big jobs. All have a built-in thermostat.
The electronic spark ignition makes them good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Air Filters | ||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, gph | Fuel Tank Capacity, gal. | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Temperature Setting, °F | Each | Each | ||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
125,000 | 16,660 cu. ft. @ 10° F 8,330 cu. ft. @ 20° F 5,550 cu. ft. @ 30° F 4,160 cu. ft. @ 40° F | 520 | 1 | 10 | 2.5 | 4" | 25" | 23" | 38" | Steel | 40° to 105° | 000000 | 0000000 | 0000000 | 000000 |
175,000 | 23,330 cu. ft. @ 10° F 11,660 cu. ft. @ 20° F 7,770 cu. ft. @ 30° F 5,830 cu. ft. @ 40° F | 600 | 1.3 | 13 | 3.2 | 4" | 27" | 24" | 44" | Steel | 40° to 105° | 0000000 | 000000 | 0000000 | 00000 |
650,000 | 86,660 cu. ft. @ 10° F 43,330 cu. ft. @ 20° F 28,880 cu. ft. @ 30° F 21,660 cu. ft. @ 40° F | 3,600 | 5 | 50 | 7.1 | 4" | 49" | 31" | 70" | Steel | 40° to 105° | 0000000 | 00000000 | 000000 | 00 |
Portable Large-Space Kerosene and Diesel Heaters



Built for big jobs, this is a powerful space heater. It has a built-in thermostat.
The electronic spark ignition makes it good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Air Filters | ||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, gph | Fuel Tank Capacity, gal. | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Temperature Setting, °F | Each | Each | ||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
75,000 | 10,000 cu. ft. @ 10° F 5,000 cu. ft. @ 20° F 3,330 cu. ft. @ 30° F 2,500 cu. ft. @ 40° F | 265 | 0.6 | 5 | 1.6 | 4" | 17" | 12" | 32" | Steel | 40° to 105° | 000000 | 0000000 | 0000000 | 000000 |
Direct Long-Range Ceiling-Mount Gas Heaters


Our most powerful ceiling-mount direct heaters, these warm people in large spaces, such as warehouses. All have a safety shut-off that cuts the gas supply if the flame goes out. They include a wall-mount thermostat.
Heaters with two burners allow for greater control over how much heat is generated—use one or both burners depending on your needs.
Heaters with a pilot light ignition do not require electricity. Heaters with an electronic spark ignition are good for drafty areas where a pilot light could be extinguished.
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 40 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 000000000 | 000000 |
60,000 | 2,050 sq. ft. @ 10° F 680 sq. ft. @ 20° F 510 sq. ft. @ 30° F 510 sq. ft. @ 40° F | 1 | 60 | 3/4 | NPT | Female | 15 | 12" | 46" | 20" | Steel | No | 50° to 90° | 00000000 | 000000 | 000000000 | 00000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 100 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 000000000 | 00000 |
120,000 | 4,100 sq. ft. @ 10° F 1,370 sq. ft. @ 20° F 1,020 sq. ft. @ 30° F 1,020 sq. ft. @ 40° F | 2 | 120 | 3/4 | NPT | Female | 36 | 11" | 83" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 000000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Pilot Burners | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 40 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 00000000 | 000000 |
70,000 | 2,050 sq. ft. @ 10° F 680 sq. ft. @ 20° F 510 sq. ft. @ 30° F 510 sq. ft. @ 40° F | 1 | 60 | 3/4 | NPT | Female | 15 | 12" | 46" | 20" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 100 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
120,000 | 4,100 sq. ft. @ 10° F 1,370 sq. ft. @ 20° F 1,020 sq. ft. @ 30° F 1,020 sq. ft. @ 40° F | 2 | 120 | 3/4 | NPT | Female | 36 | 11" | 83" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 00000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 2 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 000000000 | 000000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 5 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 000000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Pilot Burners | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 2 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 00000000 | 000000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 5 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
Direct Long-Range Portable Gas Heaters



Place at large worksites and other well-ventilated areas. These heaters have a safety shut-off that cuts the gas supply if the flame goes out.
Propane heaters with a regulator have a NGO connection (the same connection between your gas grill and propane tank).
Barrier ring guard kits keep you from accidentally bumping into heaters. They are often used in areas with high foot traffic.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Replacement Thermocouples | |||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Dia. | Housing Material | For Use Outdoors | Each | Each | ||
Pilot Light Ignition | |||||||||||||||
125,000 | 3,660 sq. ft. @ 10° F 1,830 sq. ft. @ 20° F 1,220 sq. ft. @ 30° F 910 sq. ft. @ 40° F | 125 | 1/2 | NPT | Female | 35" | 15" | 15" | __ | Steel | Yes | 0000000 | 0000000 | 0000000 | 000000 |
212,000 | 6,210 sq. ft. @ 10° F 3,100 sq. ft. @ 20° F 2,070 sq. ft. @ 30° F 1,550 sq. ft. @ 40° F | 215 | 1/2 | NPT | Female | 50" | __ | __ | 18" | Steel | No | 0000000 | 000000 | 0000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Replacement Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Dia. | Housing Material | For Use Outdoors | Includes | Each | Each | ||
Pilot Light Ignition | |||||||||||||||||
35,000 | 1,020 sq. ft. @ 10° F 510 sq. ft. @ 20° F 340 sq. ft. @ 30° F 260 sq. ft. @ 40° F | 20 | 2 | __ | NGO | __ | 35" | 10" | 13" | __ | Steel | Yes | 20-ft. Hose with Regulator | 000000 | 0000000 | 0000000 | 000000 |
125,000 | 3,660 sq. ft. @ 10° F 1,830 sq. ft. @ 20° F 1,220 sq. ft. @ 30° F 910 sq. ft. @ 40° F | 40 | 6 | __ | NGO | __ | 35" | 15" | 15" | __ | Steel | Yes | 20-ft. Hose with Regulator | 0000000 | 000000 | 0000000 | 00000 |
200,000 | 5,860 cu. ft. @ 10° F 2,930 cu. ft. @ 20° F 1,950 cu. ft. @ 30° F 1,460 cu. ft. @ 40° F | 100 | 9 | 1/2 | NPT | Female | 50" | __ | __ | 18" | Steel | No | __ | 0000000 | 000000 | 0000000 | 00000 |

For Heat Output, Btu/hr. | Each | |
200,000 212,000 | 0000000 | 0000000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
Direct Long-Range Wall-Mount Gas Heaters

Use these powerful heaters to warm people in large spaces, such as warehouses. They have a safety shut-off that cuts the gas supply if the flame goes out. They include a wall-mount thermostat.
Inlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption | Pipe Size | Thread Type | Gender | Max. Mounting Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temperature Setting, °F | Each | |
Natural Gas Heaters | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
22,000 | 640 sq. ft. @ 10° F 320 sq. ft. @ 20° F 210 sq. ft. @ 30° F 160 sq. ft. @ 40° F | 1 | 25 cfh | 1/2 | NPT | Female | 9 | 7" | 30" | 13" | Steel | No | 35° to 75° | 00000000 | 0000000 |
Propane Heaters | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
22,000 | 640 sq. ft. @ 10° F 320 sq. ft. @ 20° F 210 sq. ft. @ 30° F 160 sq. ft. @ 40° F | 1 | 1 lbs./hr. | 1/2 | NPT | Female | 9 | 7" | 30" | 13" | Steel | No | 35° to 75° | 00000000 | 000000 |
Direct Short-Range Gas Heaters


Built for outdoor use, these heaters warm people at worksites and other cold spots without access to electricity. Connect heaters to a propane tank and light with a match. They have a regulator with a NGO connection (the same connection between your gas grill and propane tank). All have a safety shut-off that cuts the gas supply if the flame goes out.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Burners | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Inlet Thread Type | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Each | |
Propane Heaters | ||||||||||||
External Lighter Ignition | ||||||||||||
1 | 15,000 | 440 sq. ft. @ 10° F 220 sq. ft. @ 20° F 150 sq. ft. @ 30° F 110 sq. ft. @ 40° F | 20 | 1 | NGO | 13" | 10" | 8" | Steel | Yes | 000000 | 000000 |
2 | 30,000 | 880 sq. ft. @ 10° F 440 sq. ft. @ 20° F 290 sq. ft. @ 30° F 220 sq. ft. @ 40° F | 20 | 1.5 | NGO | 16" | 17" | 7" | Steel | Yes | 000000 | 000000 |
Torch-Style Heat Guns for Shrink Wrap

Produce a concentrated flame for shrink-wrapping polyethylene film and other materials around small objects. Connect this gun to a propane fuel cylinder (sold separately).
Temp. Setting, °F | Heat Output | Propane Consumption, lbs./hr. | Nozzle Lg. | Thread Size | Thread Type | Gender | CGA Number | Ignition Method | Ignition Control | Each | |
3500° | 12,855 Btu/hr. @ 28 lbs/sq. in. | 0.617 | 2 1/8" | 1"-20 | UNF | Female | 600 | Self-Ignite | Trigger | 0000000 | 000000 |
Heat Guns for Shrink Wrap
Distribute heat over a wide area for large jobs. Connect to a propane fuel cylinder (sold separately) for shrink-wrapping objects with polyethylene film and other materials. This heat gun has a safety trigger that minimizes fire hazards; the flame extinguishes upon release.

Temp. Setting, °F | Heat Output | Propane Consumption, lbs./hr. | Nozzle Lg. | Housing Material | Ignition Method | Specifications Met | Includes | Each | |
1120° | 172,500 Btu/hr. @ 22 psi | 8 | 5 1/4" | Plastic | Self-Ignite | UL Listed | 25-ft. Lg. Hose Adjustable Regulator with Pressure Gauge Plastic Carrying Case Propane Tank Adapters Safety Shield | 00000000 | 0000000 |

Includes | Each | |
One Combustor One Gun Housing Assembly One Trigger/Igniter Assembly Two Retainers Four O-Rings | 00000000 | 0000000 |

Lg., ft. | Material | Each | |
4 | Aluminum | 00000000 | 0000000 |
Gas Burners
Distribute heat evenly to avoid hotspots with these heavy duty multiflame burners.

Burner | O'all | Gas Inlet | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Dia. | Lg. | Lg. | Ht. | Pipe Size | Gender | Material | Features | For Use With | Each | |
9,500 | 1/2" | 12" | 18" | 1 7/8" | 1/4 NPT | Male | Iron | Brass On/Off Valve, Gas Mixer | 000000 | 0000000 | |
24,000 | 1" | 18" | 29 1/2" | 2 3/8" | 1/2 NPT | Male | Iron | Brass On/Off Valve, Gas Mixer | 000000 | 000000 | |
42,000 | 1 1/4" | 36" | 49" | 2 3/4" | 1/2 NPT | Male | Iron | Brass On/Off Valve, Gas Mixer | 000000 | 000000 | |
66,000 | 1 1/2" | 60" | 74 1/2" | 3 3/8" | 1/2 NPT | Male | Iron | Brass On/Off Valve, Gas Mixer | 000000 | 000000 |



O'all | Gas Inlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | No. of Burner Rings | Burner Dia. | Lg. | Ht. | Pipe Size | Gender | Material | Features | For Use With | Each | |
15,000 | 1 | 4 1/2" | 15 1/2" | 5 1/4" | 1/4 NPT | Male | Iron | Brass On/Off Valve, Gas Mixer | Natural Gas | 0000000 | 0000000 |
53,000 | 2 | 8" | 15 1/2" | 5 1/4" | 1 NPT | Male | Iron | Brass On/Off Valve on Each Ring, Gas Mixer | Natural Gas | 0000000 | 000000 |
107,000 | 3 | 12" | 15 1/2" | 5 1/4" | 1 NPT | Male | Iron | Brass On/Off Valve on Each Ring, Gas Mixer | Natural Gas | 0000000 | 00000000 |

Torch-Style Gas Burners

Accelerate gas flow into an intense flame. These powerful burners are also known as venturi nozzles and buzzer burners.
For technical drawings and 3-D models, click on a part number.
Portable Gas Burners
Take these burners anywhere they can hook up to a propane tank. They are designed for outdoor use. Burners require a low-pressure gas regulator (not included).


Portable Torch-Style Gas Burners
Heat, thaw, and sterilize in areas other burners can’t reach—these burners have a handle that lets you put flames into hard-to-reach spaces. They’re also often used to get rid of weeds. Burners are for use with propane tanks.


Max. Flame | Gas Inlet | Torch-to-Hose Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Temp., °F | Dia. | Lg. | Nozzle Lg. | Handle Lg. | O'all Lg. | Thread Size | Gender | Pipe Size | Gender | For Valve Type | Hose CGA No. | Includes | Each | |
50,000 | 2000° | 2" | 8" | 4 1/2" | 10 1/2" | 15" | 7/8"-14 UNF | Male | 1/4 NPT | Female | POL | CGA 510 | 10-ft. Hose Flame-Adjusting Valve Regulator Stand Torch Lighter | 00000000 | 0000000 |
500,000 | 2000° | 12" | 24" | 5" | 28" | 33" | 7/8"-14 UNF | Male | 1/4 NPT | Female | POL | CGA 510 | 10-ft. Hose Flame-Adjusting Valve Torch Lighter | 00000000 | 000000 |
Bench-Top Gas Burners

Also known as Bunsen and Tirrill burners, separate controls adjust flame height and temperature.
For technical drawings and 3-D models, click on a part number.