Combustion Efficiency Meters
Also known as a combustion analyzer, this meter measures boiler and furnace combustion efficiency. It automatically calibrates to normal atmospheric oxygen.
Measurement Range | Calculated Range | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Use On | Ambient Temp. | Flue Gas Temp. | Flue Gas Oxygen | Carbon Monoxide, ppm | Combustion Efficiency | Carbon Dioxide | Air Free Carbon Monoxide, ppm | Excess Air | Accuracy | Batteries Included | Each | |
Kerosene, Natural Gas, Oil, Propane | 25° to 110° F | -4° to 1200° F | 0-20.9% | 0-2,000 | 0.1%-100% | 0-15% | 0-9,999 | 0-250% | ±0.3% of Oxygen Content | Yes | 0000000 | 0000000 |
Gas Leak Detectors for Hard-to-Reach Areas
Identify a variety of small leaks quickly and access hard-to-reach areas with the flexible probe. An audible signal increases in intensity the closer you get to the leak. Intrinsically safe for Class I, Divisions I and 2, Groups A, B, C, and D hazardous locations.
Detection Trigger Point, ppm | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Methane (Natural Gas) | Propane | Hydrogen | Butane | Acetone | Methanol | Ammonia | Gasoline | Chlorine | Acetylene | Ethane | Ethylene | Hydrogen Sulfide | Batteries Included | Container Type | Each | |
5 | 5 | 5 | 5 | 50 | 50 | 20 | 1 | 1 | 50 | 5 | 500 | 5 | Yes | Plastic Carrying Case | 0000000 | 0000000 |
Refrigerant Leak Detectors for Hard-to-Reach Areas
Detect halogenated refrigerants such as HFCs, CFCs, and HCFCs. Access hard-to-reach areas with the flexible probe. This unit can detect leaks as small as 0.1 oz. per year in air conditioning and refrigeration systems. An audible signal increases in intensity as you approach the leak.
Gas Type Detected | Probe Lg. | Batteries Included | Container Type | Specifications Met | Each | |
Hydrofluorocarbons (HFCs), Chlorofluorocarbons (CFCs), Hydrochlorofluorocarbons (HCFCs), R-22 (Freon) Refrigerant, R-134A Refrigerant, R-410A Refrigerant | 14" | Yes | Plastic Carrying Case | UL Recognized Component, CE Marked, SAE J2791, SAE J2913 | 0000000 | 0000000 |
Portable Multi-Gas Detectors with Probe
Use the probe to test the air in a hazardous area before entering. Great for confined spaces. This detector alerts you with an audible alarm, warning light, and vibrating alarm in the presence of combustible and toxic gases. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Includes | Tube Lg., ft. | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL), Oxygen (0-30% Vol.), Carbon Monoxide (0-1,999 ppm), Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | Sampling Probe, Tubing Assembly, Rechargeable Lithium Ion Battery for Probe | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |