About Pressure Gauges
More
About Pressure Transmitters
More
About Flowmeters and Totalizers
Flowmeters measure the rate of flow for a liquid or a gas. Totalizers measure the cumulative flow volume. Flowmeter/totalizers display both the flow rate and the cumulative flow volume.
More
Low-Pressure Differential Gauges with U-Tube
Also known as manometers, these gauges come with indicating liquid that moves up and down two columns—the difference in height between them is your pressure. They are commonly used to indicate clogged filters.
Magnet-mount gauges can be moved for use in multiple locations. Gauges with barbed tube connection have a flexible body that rolls up for storage or transport.
For technical drawings and 3-D models, click on a part number.

- For Use With: Air, Argon, Carbon Dioxide, and Hydrogen
- Accuracy: Not Rated (Not Graded)
Pressure Range, in. of H₂O | Scale Range, in. of H₂O | Numeric Increments, in. of H₂O | Graduation Marks, in. of H₂O | Max. Pressure | Ht. | Max. Process Temp., °F | Gender | Mount Type | Each | |
With Barbed Tube Connection for 3/16" Tube ID | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0-8 | 4-0-4 | 1 | 0.1 | Not Rated | 17" | 130° | Male | Magnet | 0000000 | 0000000 |
0-12 | 6-0-6 | 1 | 0.1 | Not Rated | 21" | 130° | Male | Magnet | 0000000 | 000000 |
0-16 | 8-0-8 | 1 | 0.1 | Not Rated | 25" | 130° | Male | Magnet | 0000000 | 000000 |
0-24 | 12-0-12 | 1 | 0.1 | Not Rated | 33" | 130° | Male | Magnet | 0000000 | 000000 |
0-30 | 15-0-15 | 1 | 0.1 | Not Rated | 39" | 130° | Male | Magnet | 0000000 | 000000 |
0-36 | 18-0-18 | 1 | 0.1 | Not Rated | 45" | 130° | Male | Magnet | 0000000 | 000000 |
0-48 | 24-0-24 | 1 | 0.1 | Not Rated | 57" | 130° | Male | Magnet | 0000000 | 000000 |
0-60 | 30-0-30 | 1 | 0.1 | Not Rated | 69" | 130° | Male | Magnet | 0000000 | 000000 |
0-72 | 36-0-36 | 1 | 0.1 | Not Rated | 81" | 130° | Male | Magnet | 0000000 | 000000 |
Low-Pressure Differential Gauges with Inclined Scale
Easier to read than U-tube gauges, these use an inclined scale to measure pressure or velocity in air applications. Gauges are also known as manometers.

- For Use With: Air
- Accuracy: ±3% Full Scale (Not Graded)
Indicating Liquid | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, in. of H₂O | Max. Pressure, psi | Max. Process Temp. Range, °F | Ht. | Color | Specific Gravity | Mount Type | Mounting Fasteners Included | Includes | Each | |
With Barbed Tube Connection for 3/16" Tube ID | ||||||||||
0-3 | 10 | 140° | 6" | Red | 0.826 | Screw On | Yes | 8-ft. Lg. Tubing; Indicating Liquid | 000000 | 000000 |
0-7 | 10 | 140° | 6" | Blue | 1.91 | Screw On | Yes | 8-ft. Lg. Tubing; Indicating Liquid | 000000 | 000000 |
Low-Pressure Differential Gauges with Digital Display

Measure small changes in air pressure with these hand-held gauges. They have a four-digit LCD display for easy reading of measurements. Gauges are commonly used to indicate clogged filters and to monitor fans and blowers.
- For Use With: Air, Natural Gas
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | bar | Resolution, psi | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
Barbed Tube Connection | |||||||||||||
0-30 | 0-2.069 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | |||||||||||||
0-30 | 0-2.069 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Optional Nylon Carrying Case | 0000000 | Each | 000000 |
- For Use With: Air, Natural Gas
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
kPa | in. of H₂O | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
Barbed Tube Connection | |||||||||||||
0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 |
0-49.82 | 0-200 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | |||||||||||||
0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
0-49.82 | 0-200 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Optional Nylon Carrying Case | 0000000 | Each | 000000 |
Differential Pressure and Vacuum Gauges with Digital Display
Gauges have a four-digit LCD display for easy reading of measurements. Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.

- For Use With: Air
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | kPa | in. of H₂O | mbar | Vacuum Range, in. of Hg | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Batteries Included | Features | Each | |
Barbed Tube Connection | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 0000000 |
0-7.225 | 0-49.82 | 0-200" | 0-498.2 | 14.71"-0 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-20 | 0-137.9 | 0-553" | 0-1,379 | 40.72"-0 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-7.225 | 0-49.82 | 0-200" | 0-498.2 | 14.71"-0 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-20 | 0-137.9 | 0-553" | 0-1,379 | 40.72"-0 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
Air Sensors for Differential Pressure



Use these sensors with differential pressure gauges and switches to measure the static pressure drop across air filters, cooling coils, and blowers in air-handling equipment. Install them in duct through a hole and connect to your gauge with tubing.
Sensors with pressure tubes give more accurate measurements in applications with high air flow. Style D is held in place with a magnet so you can move it for use in multiple locations.
For technical drawings and 3-D models, click on a part number.
Differential Pressure Transmitters with Digital Display for Air
With a digital display and selectable differential pressure ranges, these transmitters are a versatile alternative to transmitters with dial indicators. Unlike a standard transmitter that has one wider differential pressure range, these transmitters have multiple ranges to choose from. The selectable pressure range means they are more accurate than standard transmitters since their accuracy applies to each small range rather than a single wide range. They can also be configured to output either current or voltage, while standard transmitters typically output one signal type. The digital display allows you to troubleshoot and monitor differential pressure at the source. Also known as transducers, they measure the difference in pressure between two inputs and convert it to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are rated UL 94 V-0, so they meet flammability standards. CE marked, they also meet European safety standards.
When measuring pressure in ductwork, pair them with a static pressure probe. Transmitters with an 8" pressure probe cable include a static pressure probe.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
Connect them using two wires when using the current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. For voltage output, connect them using three wires—two wires into the power supply and a separate wire to send a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
DIN-rail/surface mount transmitters give you mounting flexibility. They include the bracket you'll need for mounting it to DIN rail.
Transmitters with a calibration certificate traceable to NIST have passed tests for accuracy.
IP66 rated transmitters protect against dust and washdowns. Transmitters that meet IP67 protect against dust and submersion. NEMA 4X rated transmitters protect against dirt, weather, corrosion, and washdowns.

- For Use With: Air
- Accuracy: ±1%
- Tube Connection Type: Barbed
- Connection Material: Nylon Plastic
- Temperature Range: -4° to 158° F
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, in. of H2O | Max. Input Pressure, in. of H2O | Input Voltage | For Tube ID | Mounting Hardware Included | Dia. | No. of | Ht. | Dp. | Environmental Rating | Each | |
4-20 mA, 0-5V DC, 0-10V DC Output Signal—Screw Terminals | |||||||||||
Surface Mount | |||||||||||
0 to 0.1 0 to 0.15 0 to 0.25 0 to 0.5 | 99 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 0000000 |
0 to 1 0 to 2 0 to 3 0 to 5 | 166 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 000000 |
0 to 10 0 to 15 0 to 25 0 to 28 | 166 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 000000 |

- For Use With: Air
- Accuracy: ±1%
- Tube Connection Type: Barbed
- Connection Material: Brass
- Temperature Range: 32° to 122° F
Mounting Holes | Transmitters with Calibration Certificate Traceable to NIST | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, in. of H2O | Max. Input Pressure, psi | Input Voltage | For Tube ID | For DIN Rail Ht., mm | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Pressure Probe Cable Length | Environmental Rating | Each | |
4-20 mA, 0-5V DC, 0-10V DC Output Signal—Screw Terminals | |||||||||||||
Surface Mount | |||||||||||||
-5 to 5 -2.5 to 2.5 -1 to 1 -0.5 to 0.5 0 to 0.5 0 to 1 0 to 2.5 0 to 5 | 10 | 13-30V DC | 3/16" | __ | No | 3/16" | 2 | 5 7/16" | 3 3/16" | __ | IP67 | 0000000 | 0000000 |
DIN-Rail/Surface Mount | |||||||||||||
-5 to 5 -2.5 to 2.5 -1 to 1 -0.5 to 0.5 0 to 0.5 0 to 1 0 to 2.5 0 to 5 | 10 | 13-30V DC | 3/16" | 35 | No | 3/16" | 2 | 5 7/16" | 3 3/16" | 8" | IP67 | 0000000 | 000000 |
Differential Pressure Transmitters for Air

- For Use With: Air
- Accuracy: ±0.8%
- Tube Connection: Barbed
- Housing Material: ABS Plastic
- Connection Material: Brass
- Temperature Range: 0° to 160° F
Remotely monitor the difference in air pressure between two inputs with these transmitters. Also known as transducers, they convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. These transmitters are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. They mount directly to DIN rail or a flat surface without the need for additional brackets. CE marked, all meet European safety standards. These transmitters are rated NEMA 1 for indoor use.
When measuring pressure in ductwork, pair them with a static pressure probe.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range , in. of H2O | Max. Input Pressure, in. of H2O | Input Voltage | For Tube ID | For DIN Rail Ht., mm | Mounting Hardware Included | Top Dia. (No. of) | Bottom Dia. (No. of) | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Output Signal—Screw Terminals | ||||||||||||
DIN Rail or Surface Mount | ||||||||||||
-15 to 15 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 0000000 |
-10 to 10 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-5 to 5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-2.5 to 2.5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-1 to 1 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-0.5 to 0.5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-0.25 to 0.25 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
-0.1 to 0.1 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 0.1 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 0.25 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 0.5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 1 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 2.5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 5 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 10 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 25 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 50 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
0 to 100 | 415 | 12-36V DC | 1/8" | 35 | No | 3/16" (2) | 5/32" (2) | 3 5/16" | 1 7/8" | NEMA 1 | 0000000 | 000000 |
Flowmeters for Oxygen

To prevent contaminating your oxygen line, these flowmeters are specially cleaned and bagged. As oxygen flows through, it pushes an indicator up the scale, showing you the flow rate. Mount these flowmeters vertically inline with your oxygen system, so oxygen flows up from the bottom. The flow-control knob lets you open and close the valve at the inlet to adjust the flow rate within the range.
These flowmeters are calibrated with oxygen but can be used with other gases. If you’re using these with a gas other than oxygen, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
For technical drawings and 3-D models, click on a part number.
Flow Range, lpm | Overall Ht. | Accuracy | Max. Pressure | Max. Temp., °F | Body Material | Seal Material | Mounting Orientation | Features | Each | |
Brass Fittings | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/8 NPT Female Inlet × Barbed Outlet for 1/4" Tube ID | ||||||||||
0 to 30 | 7 1/4" | ±10% | 50 psi @ 70° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 00000000 | 0000000 |
0.25 to 3.5 | 7 1/4" | ±10% | 150 psi @ 72° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 0000000 | 000000 |
0.5 to 8 | 7 1/4" | ±10% | 150 psi @ 72° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 0000000 | 000000 |
0.5 to 15 | 7 1/4" | ±10% | 150 psi @ 72° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 0000000 | 000000 |
1/4 NPT Female Inlet × Barbed Outlet for 1/4" Tube ID | ||||||||||
0 to 3.5 | 7 1/4" | ±10% | 50 psi @ 70° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 00000000 | 000000 |
0 to 8 | 7 1/4" | ±10% | 50 psi @ 70° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 00000000 | 000000 |
0 to 15 | 7 1/4" | ±10% | 50 psi @ 70° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 00000000 | 000000 |
0 to 30 | 7 1/4" | ±10% | 50 psi @ 70° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 00000000 | 000000 |
0 to 70 | 7 1/4" | ±10% | 50 psi @ 70° F | 140° | Polycarbonate Plastic | Fluoroelastomer Rubber | Vertical | Flow-Control Knob | 00000000 | 000000 |
Flow Sights with Barbed Fittings for Water, Oil, Air, and Inert Gas


Monitor liquid movement, color, and clarity in tube systems—these sights have barbed fittings that slide into soft plastic and rubber tubing. They have a clear body and an indicator that moves when flow is present, so you can visually confirm flow from a distance.
Indicator | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Tube ID | Temp. Range, °F | End-to-End Lg. | Ht. | Max. Pressure | Direction of Flow | Material | Color | For Use With | Each | |
Ball Indicator | ||||||||||
Polycarbonate Plastic Body | ||||||||||
1/4" to 3/8" | 32° to 180° | 3" | 2 1/4" | 10 psi @ 70° F | Bottom to Top, Left to Right, Right to Left, Top to Bottom | Nylon Plastic | White | Water, Oil, Air, Inert Gas | 0000000 | 000000 |
Rotor Indicator | ||||||||||
Polymethylpentene Plastic Body | ||||||||||
1/4" to 7/16" | 32° to 140° | 3 1/2" | 1 9/16" | 20 psi @ 70° F | Bottom to Top, Left to Right, Right to Left, Top to Bottom | Polypropylene Plastic | Blue | Water, Mineral Oil, Air, Inert Gas | 0000000 | 00000 |
Polystyrene Plastic Body | ||||||||||
3/16" to 1/4" | 0° to 190° | 2" | 1" | 10 psi @ 70° F | Bottom to Top, Left to Right, Right to Left, Top to Bottom | Polystyrene Plastic | Blue | Water, Oil, Air, Inert Gas | 0000000 | 00000 |