About Flowmeters and Totalizers
Flowmeters measure the rate of flow for a liquid or a gas. Totalizers measure the cumulative flow volume. Flowmeter/totalizers display both the flow rate and the cumulative flow volume.
More
Flowmeter/Totalizers
Determine the flow rate and total volume of liquid flowing through your system with the same meter. To measure flow, these flowmeter/totalizers count how many times their turbine turns as liquid passes through. Use them only with clean, low-viscosity liquids to avoid clogging the turbine and other damage to these flowmeter/totalizers. You can reset the batch total, but you can’t reset the cumulative total. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
These flowmeter/totalizers are either calibrated with water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
Choose a fitting material that is compatible with the liquid you're running through your line. PVC, nylon, and PVDF plastic fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened. 316 stainless steel fittings resist impact better than plastic fittings.
Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states they’ve passed a test for accuracy.
IP rated, all seal out dust and can be lightly rinsed. NEMA 4 flowmeter/totalizers protect against weather and washdowns. FM-approved flowmeter/totalizers are safe for use in hazardous location.
90° display adapter kits let you rotate the meter’s display 90°, so you can read it easier when mounted vertically.
Output modules allow you to transmit flow data from flowmeter/totalizers to an external device such as a programmable logic controller (PLC), data recorder, logger, and remote display (not included). 4-20 mA output modules have an analog output. As flow increases, the output signal from the transmitter increases. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Pulse output modules have a digital output. They transmit flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
Remote panel-mounting kits let you mount the meter’s display up to 10 feet away.
Flowmeter/Totalizers | Replacement Displays | Replacement Rotor Kits | 90° Display Adapter Kits | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | Pipe Schedule | End-to-End Lg. | Accuracy | Max. Total Volume, gallons | Max. Batch Volume, gallons | Max. Pressure | Temp. Range, °F | Batteries Included | Environmental Rating | Each | Each | Each | Each | ||||
Flowmeter/Totalizers | ||||||||||||||||||
1/2 NPT Female | 1 to 10 | 80 | 6" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 0000000 | 00000000 | 0000000 | 000000 | 00 | 00000000 | 000000 |
3/4 NPT Female | 2 to 20 | 80 | 6 1/8" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
1 NPT Female | 5 to 50 | 80 | 6 1/2" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
1 1/2 NPT Female | 10 to 100 | 80 | 7 5/8" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
2 NPT Female | 20 to 200 | 80 | 7 7/8" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
4 NPT Female | 60 to 600 | 80 | 17" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 0000000 | 00000000 | 00000 |
Flowmeter/Totalizers with Calibration Certificate Traceable to NIST | ||||||||||||||||||
1/2 NPT Female | 1 to 10 | 80 | 6" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
3/4 NPT Female | 2 to 20 | 80 | 6 1/8" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
1 NPT Female | 5 to 50 | 80 | 6 1/2" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
1 1/2 NPT Female | 10 to 100 | 80 | 7 5/8" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 00000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
2 NPT Female | 20 to 200 | 80 | 7 7/8" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 00000000 | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 |
4 NPT Female | 60 to 600 | 80 | 17" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Yes | IP65 NEMA 4 | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 00000 |
Flowmeter/Totalizers | 90° Display Adapter Kits | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | Pipe Schedule | End-to-End Lg. | Accuracy | Max. Total Volume, gallons | Max. Batch Volume, gallons | Max. Pressure | Temp. Range, °F | Batteries Included | Environmental Rating | Specifications Met | Each | Each | ||
Flowmeter/Totalizers | |||||||||||||||
1 NPT Female | 0.3 to 3 | 80 | 4" | ±1.5% | 999,999 | 999,999 | 150 psi @ 70 ° F | 14° to 140° | Yes | IP65 NEMA 4 NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; | FM Approved, AEx ia IIC T4 | 00000000 | 0000000 | 00000000 | 000000 |
Flowmeter/Totalizers with Calibration Certificate Traceable to NIST | |||||||||||||||
1 NPT Female | 0.3 to 3 | 80 | 4" | ±1.5% | 999,999 | 999,999 | 150 psi @ 70 ° F | 14° to 140° | Yes | IP65 NEMA 4 NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; | FM Approved, AEx ia IIC T4 | 00000000 | 000000 | 00000000 | 00000 |
Flowmeter/Totalizers | Replacement Displays | Replacement Rotor Kits | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | Pipe Schedule | End-to-End Lg. | Accuracy | Max. Total Volume, gallons | Max. Batch Volume, gallons | Max. Pressure | Temp. Range, °F | Batteries Included | Environmental Rating | Specifications Met | Each | Each | Each | |||
Flowmeter/Totalizers | |||||||||||||||||
1/2 NPT Female | 1.2 to 12 | 80 | 7 5/16" | ±2% | 999,999 | 999,999 | 100 psi @ 70 ° F | 0° to 125° | Yes | IP65 NEMA 4 NEC Class I Divisions 1, 2 Groups A, B, C, D; | FM Approved, AEx ia IIC T4 | 00000000 | 000000000 | 00000000 | 0000000 | 00000000 | 0000000 |
1 NPT Female | 5 to 50 | 80 | 8 1/16" | ±1.5% | 999,999 | 999,999 | 100 psi @ 70 ° F | 0° to 125° | Yes | IP65 NEMA 4 NEC Class I Divisions 1, 2 Groups A, B, C, D; | FM Approved, AEx ia IIC T4 | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
Flowmeter/Totalizers with Calibration Certificate Traceable to NIST | |||||||||||||||||
1/2 NPT Female | 1.2 to 12 | 80 | 7 5/16" | ±2% | 999,999 | 999,999 | 100 psi @ 70 ° F | 0° to 125° | Yes | IP65 NEMA 4 NEC Class I Divisions 1, 2 Groups A, B, C, D; | FM Approved, AEx ia IIC T4 | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
1 NPT Female | 5 to 50 | 80 | 8 1/16" | ±1.5% | 999,999 | 999,999 | 100 psi @ 70 ° F | 0° to 125° | Yes | IP65 NEMA 4 NEC Class I Divisions 1, 2 Groups A, B, C, D; | FM Approved, AEx ia IIC T4 | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
Flowmeter/Totalizers | Replacement Displays | 90° Display Adapter Kits | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Total Volume, gallons | Max. Batch Volume, gallons | Max. Pressure | Temp. Range, °F | Batteries Included | Environmental Rating | Specifications Met | Each | Each | Each | |||
Flowmeter/Totalizers | ||||||||||||||||
1/2 NPT Female | 1 to 10 | 4 1/4" | ±1.5% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 0000000 | 00000000 | 0000000 | 00000000 | 000000 |
3/4 NPT Female | 2 to 20 | 4 3/8" | ±1% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 00000 |
1 NPT Female | 5 to 50 | 4 1/2" | ±1% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 |
1 1/2 NPT Female | 10 to 100 | 5 3/8" | ±0.75% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 |
2 NPT Female | 20 to 200 | 6 3/8" | ±0.75% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 |
Flowmeter/Totalizers with Calibration Certificate Traceable to NIST | ||||||||||||||||
1/2 NPT Female | 1 to 10 | 4 1/4" | ±1.5% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 |
3/4 NPT Female | 2 to 20 | 4 3/8" | ±1% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 |
1 NPT Female | 5 to 50 | 4 1/2" | ±1% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 |
1 1/2 NPT Female | 10 to 100 | 5 3/8" | ±0.75% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 |
2 NPT Female | 20 to 200 | 6 3/8" | ±0.75% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2; IP65 | FM Approved, CE Marked, ATEX II 1 G Ex ia IIC T4 Ga, C-FM Approved, IECEx Ex ia IIC T4 Ga | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 |
Component | Number of Wire Leads | Wire Lead Lg., ft. | Input Voltage Range | Includes | Pkg. Qty. | For Flow Measurement Type | Each | |
4-20 mA Output Module | 4 | 10 | 8V DC to 26V DC | __ | __ | Turbine | 00000000 | 0000000 |
Remote Panel-Mounting Kit | __ | __ | __ | __ | __ | Turbine | 00000000 | 000000 |
90° Display Adapter Kits | __ | __ | __ | 12 Screws, 90° Display Adapter, Nitrile Rubber O-Ring | __ | Turbine | 00000000 | 00000 |
Pkg. | ||||||||
---|---|---|---|---|---|---|---|---|
Disposable Batteries | __ | __ | __ | __ | 4 | __ | 00000000 | 0000 |
Socket-Connect Flowmeter/Totalizers with Remote Display
Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. Use them to measure the rate and volume of liquid flowing through your system. They measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Batch totals are resettable but can be protected with a security code to prevent tampering. The reset function can also be disabled so that they operate as a cumulative totalizer. Cumulative totals cannot be reset. No matter the mounting orientation, they’ll measure flow correctly.
These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
For a complete unit, you’ll need a display, a sensor, and a tee fitting (all sold separately).
Displays are rated NEMA 4X and IP65 for protection against dust, weather, washdowns, and corrosion.
Sensors thread onto the tee fitting (sold separately).
Tee fittings mount inline with your pipe. They have two unthreaded socket ends that bond to unthreaded PVC pipe with PVC cement and primer.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Max. Total Volume | Accuracy | Max. Pressure | Temperature Range, °F | DIN Trade Size | Ht., mm | Wd., mm | Dp., mm | Batteries Included | Environmental Rating | Each | |
9,999 gallons, 9,999 liters | ±0.5% | 180 psi @ 70° F | 33° to 149° | 1/4 | 96 | 96 | 41 | Yes | IP65, NEMA 4X | 00000000 | 0000000 |
Optional Surface-Mounting Bracket (Four 3/16" × 3/4" Mounting Slots) | 0000000 | Each | 000000 |
Pipe Connections | ||||||||
---|---|---|---|---|---|---|---|---|
Inlet/Outlet | Sensor | Pipe Schedule | Flow Range, gpm | Max. Pressure | Temp. Range, °F | Mounting Orientation | Each | |
PVC Plastic Body | ||||||||
1/2 Socket-Connect Pipe | 1 1/4 NPSM Threaded Male Pipe | 80 | 1 to 18.9 | 180 psi @ 70° F | 33° to 149° | Any | 00000000 | 0000000 |
3/4 Socket-Connect Pipe | 1 1/4 NPSM Threaded Male Pipe | 80 | 1.7 to 33.2 | 180 psi @ 70° F | 33° to 149° | Any | 00000000 | 000000 |
1 Socket-Connect Pipe | 1 1/4 NPSM Threaded Male Pipe | 80 | 2.7 to 53.9 | 180 psi @ 70° F | 33° to 149° | Any | 00000000 | 000000 |
1 1/2 Socket-Connect Pipe | 1 1/4 NPSM Threaded Male Pipe | 80 | 6.4 to 126.9 | 180 psi @ 70° F | 33° to 149° | Any | 00000000 | 000000 |
2 Socket-Connect Pipe | 1 1/4 NPSM Threaded Male Pipe | 80 | 10.5 to 209.2 | 180 psi @ 70° F | 33° to 149° | Any | 00000000 | 000000 |
3 Socket-Connect Pipe | 1 1/4 NPSM Threaded Male Pipe | 80 | 23 to 460.8 | 180 psi @ 70° F | 33° to 149° | Any | 00000000 | 000000 |
Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings
Easy to remove for cleaning and maintenance, these flowmeter/totalizers connect to sanitary quick-clamp fittings (often called tri-clamp fittings) and measure the flow rate and volume of liquid passing through your system. You'll need a gasket and clamp (not included) to connect these to your line. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation.
For use in hazardous locations, these flowmeter/totalizers are FM-approved. They’re also rated NEMA 4 to protect against weather and washdowns.
These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
Flowmeter/totalizers with a calibration certificate traceable to NIST states that the flowmeter/totalizer has passed a test for accuracy.
90° display adapter kits let you rotate the meter’s display 90°, so you can read it easier when mounted vertically.
Flowmeter/Totalizers | Replacement Displays | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Gender | Flow Range, gpm | Flange OD | End-to-End Lg. | Accuracy | Max. Total Volume, gallons | Max. Batch Volume, gallons | Max. Pressure | Temp. Range, °F | Each | Each | ||
Flowmeter/Totalizers | |||||||||||||
316 Stainless Steel Body with 316 Stainless Steel Fittings | |||||||||||||
3/4" | Female | 1 to 10 | 0.984" | 5" | ±1.5% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 000000000 | 00000000 | 0000000 |
1" | Female | 2 to 20 | 1.984" | 5" | ±1% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
1 1/2" | Female | 5 to 50 | 1.984" | 5 1/2" | ±1% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
2" | Female | 10 to 100 | 2.515" | 6 1/2" | ±0.75% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
2 1/2" | Female | 20 to 200 | 3.047" | 7" | ±0.75% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
Flowmeter/Totalizers with Certificate of Calibration Traceable to NIST | |||||||||||||
316 Stainless Steel Body with 316 Stainless Steel Fittings | |||||||||||||
3/4" | Female | 1 to 10 | 0.984" | 5" | ±1.5% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
1" | Female | 2 to 20 | 1.984" | 5" | ±1% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
1 1/2" | Female | 5 to 50 | 1.984" | 5 1/2" | ±1% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
2" | Female | 10 to 100 | 2.515" | 6 1/2" | ±0.75% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
2 1/2" | Female | 20 to 200 | 3.047" | 7" | ±0.75% | 999,999 | 999,999 | 1500 psi @ 70 ° F | 14° to 140° | 0000000 | 00000000 | 00000000 | 000000 |
Socket-Connect Flowmeter/Totalizers
The unthreaded ends of these flowmeter/totalizers install into a PVC piping system, so you can measure the flow rate and volume of liquid passing through your system. Bond the joint together with PVC cement and primer. You can reset the batch total, but you can't reset the cumulative total. They measure flow correctly no matter the mounting orientation.
These flowmeter/totalizers are calibrated with water.
Turbine flowmeter/totalizers measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
Ultrasonic flowmeter/totalizers measure flow with ultrasonic waves, so they don’t have internal moving parts that can break or get stuck.
Output modules allow you to transmit flow data from flowmeter/totalizers to an external device such as a programmable logic controller (PLC), data recorder, logger, and remote display (not included). 4-20 mA output modules have an analog output. As flow increases, the output signal from the transmitter increases. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Pulse output modules have a digital output. They transmit flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
Remote panel-mounting kits let you mount the meter’s display up to 10 feet away.
90° display adapter kits let you rotate the meter’s display 90°, so you can read it easier when mounted vertically.
For technical drawings and 3-D models, click on a part number.
Flowmeter/Totalizers | Replacement Displays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | Pipe Schedule | End-to-End Lg. | Accuracy | Max. Total Volume, gallons | Max. Batch Volume, gallons | Max. Pressure | Temp. Range, °F | Mounting Orientation | Batteries Included | Each | Each | ||
Turbine Flow Measurement | ||||||||||||||
PVC Plastic Body with PVC Plastic Fittings and 316 Stainless Steel Seals | ||||||||||||||
1/2 Male | 1 to 10 | 80 | 4 5/16" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Any | Yes | 00000000 | 0000000 | 00000000 | 0000000 |
3/4 Male | 2 to 20 | 80 | 4 7/16" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Any | Yes | 00000000 | 000000 | 00000000 | 000000 |
1 Male | 5 to 50 | 80 | 4 1/2" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Any | Yes | 00000000 | 000000 | 00000000 | 000000 |
1 1/2 Male | 10 to 100 | 80 | 5 3/8" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Any | Yes | 00000000 | 000000 | 00000000 | 000000 |
2 Male | 20 to 200 | 80 | 5 1/2" | ±3% | 999,999 | 999,999 | 225 psi @ 70 ° F | 33° to 140° | Any | Yes | 00000000 | 000000 | 00000000 | 000000 |
Ultrasonic Flow Measurement | ||||||||||||||
PVC Plastic Body with PVC Plastic Fittings and EPDM Rubber Seals | ||||||||||||||
3 Male | 2.06 to 309 | 80 | 6 5/8" | ±2% | 999,999 | 999,999 | 200 psi @ 70 ° F | 32° to 140° | Any | Yes | 0000000 | 00000000 | 00000000 | 000000 |
4 Male | 3.58 to 537 | 80 | 7 3/8" | ±2% | 999,999 | 999,999 | 200 psi @ 70 ° F | 32° to 140° | Any | Yes | 0000000 | 00000000 | 00000000 | 000000 |
(Flowmeter/Totalizer
Sold Separately)
Component | Number of Wire Leads | Wire Lead Lg., ft. | Input Voltage Range | Pkg. Qty. | For Flow Measurement Type | Each | |
4-20 mA Output Module | 4 | 10 | 8V DC to 26V DC | __ | Turbine | 00000000 | 0000000 |
Remote Panel-Mounting Kit | __ | __ | __ | __ | Turbine | 00000000 | 000000 |
90° Display Adapter Kits | __ | __ | __ | __ | Turbine | 00000000 | 00000 |
Pkg. | |||||||
---|---|---|---|---|---|---|---|
Disposable Batteries | __ | __ | __ | 4 | __ | 00000000 | 0000 |
Flanged Flowmeter/Totalizers
Using the flanged ends, securely install these flowmeter/totalizers in large, high-flow pipelines to measure the flow rate and total volume of liquid flowing through. They use ultrasonic waves to measure flow, so they don’t have any internal moving parts that can break or get stuck. You can reset the batch total, but you can't reset the cumulative total. They measure accurately in any mounting orientation.
These flowmeter/totalizers are calibrated with water.
For technical drawings and 3-D models, click on a part number.
Flowmeter/Totalizers | Replacement Displays | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Range, gpm | Flange OD | For Flange ANSI Class | End-to-End Lg. | Accuracy | Max Total Volume, gallons | Max. Batch Volume, gallons | Max. Pressure | Temp. Range, °F | Mounting Orientation | Batteries Included | Each | Each | ||
PVC Plastic Body with PVC Plastic Fittings and EPDM Rubber Seal | |||||||||||||||
3 | 2.06 to 309 | 7 1/2" | 150 | 13 1/4" | ±2% | 999,999 | 999,999 | 200 psi @ 70 ° F | 32° to 140° | Any | Yes | 0000000 | 000000000 | 00000000 | 0000000 |
4 | 3.58 to 537 | 9" | 150 | 13 3/16" | ±2% | 999,999 | 999,999 | 200 psi @ 70 ° F | 32° to 140° | Any | Yes | 0000000 | 00000000 | 00000000 | 000000 |
High-Temperature Flowmeter/Totalizers
With one meter, these flowmeter/totalizers measure the flow rate and total flow volume of high-temperature liquid up to 200° F. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow correctly no matter the mounting orientation.
These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
Max. Volume, gallons | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Total | Batch | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Batteries Included | Environmental Rating | Each | |
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||||
3/8 NPT Male | 0.8 to 8 | 4 3/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 0000000 |
1/2 NPT Male | 2 to 20 | 5 1/8" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
3/4 NPT Male | 3 to 30 | 5 1/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1 NPT Male | 5 to 50 | 5 5/8" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1 1/2 NPT Male | 6 to 60 | 6 1/2" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
2 NPT Male | 10 to 100 | 6 3/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
Flowmeter/Totalizers for Oil and Fuel
Use these flowmeter/totalizers to measure both the flow rate and total flow volume of oil, gasoline, diesel fuel, and kerosene. They count how many times their turbine turns as liquid passes through them to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation. Rated NEMA 4 and IP65, they seal out dust and protect against washdowns.
These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
Flowmeter/totalizers with a calibration certificate traceable to NIST states that the flowmeter/totalizer has passed a test for accuracy.
Output modules allow you to transmit flow data from flowmeter/totalizers to an external device such as a programmable logic controller (PLC), data recorder, logger, and remote display (not included). 4-20 mA output modules have an analog output. As flow increases, the output signal from the transmitter increases. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Pulse output modules have a digital output. They transmit flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
Remote panel-mounting kits let you mount the meter’s display up to 10 feet away.
90° display adapter kits let you rotate the meter’s display 90°, so you can read it easier when mounted vertically.
Flowmeter/Totalizers | Replacement Displays | Replacement Rotor Kits | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Total Volume, gallons | Max Batch Volume, gallons | Max. Pressure | Mounting Orientation | Batteries Included | Each | Each | Each | |||
Flowmeter/Totalizers | ||||||||||||||
1/2 NPT Female | 1 to 10 | 4 3/16" | ±2% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 0000000 | 00000000 | 0000000 | 00000000 | 0000000 |
3/4 NPT Female | 2 to 20 | 4 5/16" | ±1.5% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 000000 |
1 NPT Female | 0.3 to 3 | 4" | ±5% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
1 NPT Female | 3 to 50 | 4" | ±1.5% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
1 1/2 NPT Female | 10 to 100 | 5 5/16" | ±1% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
2 NPT Female | 30 to 300 | 6" | ±1.5% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 00000000 | 00000000 | 000000 | 000000 | 00 |
Flowmeter/Totalizers with Calibration Certificate Traceable to NIST | ||||||||||||||
1/2 NPT Female | 1 to 10 | 4 3/16" | ±2% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
3/4 NPT Female | 2 to 20 | 4 5/16" | ±1.5% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
1 NPT Female | 0.3 to 3 | 4" | ±5% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
1 NPT Female | 3 to 50 | 4" | ±1.5% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
1 1/2 NPT Female | 10 to 100 | 5 5/16" | ±1% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
2 NPT Female | 30 to 300 | 6" | ±1.5% | 999,999 | 999,999 | 300 psi @ 70 ° F | Any | Yes | 00000000 | 00000000 | 00000000 | 000000 | 000000 | 00 |
Component | Number of Wire Leads | Wire Lead Lg., ft. | Input Voltage Range | Pkg. Qty. | For Flow Measurement Type | Each | |
4-20 mA Output Module | 4 | 10 | 8V DC to 26V DC | __ | Turbine | 00000000 | 0000000 |
Remote Panel-Mounting Kit | __ | __ | __ | __ | Turbine | 00000000 | 000000 |
90° Display Adapter Kits | __ | __ | __ | __ | Turbine | 00000000 | 00000 |
Pkg. | |||||||
---|---|---|---|---|---|---|---|
Disposable Batteries | __ | __ | __ | 4 | __ | 00000000 | 0000 |