McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    38 Products
    About Pressure Gauges
    industrial info icon

    Find a gauge with the right connection material and dial type—many with traceable calibration certificates.

    High-Accuracy Low-Pressure Gauges

    Measure small pressure changes in ventilation systems, hydraulic applications, and other critical processes with these high-accuracy gauges. Mount them with the dial face upright.
    Painted Steel Case with Brass Connection—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Pressure Gauges. High-Accuracy Low-Pressure Gauges, Single Scale, Bottom Connection.
    Image of Product. Front orientation. Pressure Gauges. High-Accuracy Low-Pressure Gauges, Single Scale, Center-Back Connection.
    Image of Attribute. Bottom Connection. Front orientation. High-Accuracy Low-Pressure Gauges, Bottom Connection.
    Image of Attribute. Center-Back Connection. Front orientation. High-Accuracy Low-Pressure Gauges, Center-Back Connection.

    Bottom Connection

    Center-Back

    Connection

    Bottom

    Connection

    Center-Back

    Connection

    Temp.
    Range, ° F
    Bottom
    Connection
    Center-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Case
    Color
    Environment
    Process
    For Use With
    Accuracy
    Pressure
    Range
    Each
    Each
    Upright Mount
     
    NPT Male
    2 1/2"1/4
    Black0 to 1400 to 140Air
    Carbon Dioxide
    Hydraulic Fluid
    Natural Gas
    Water
    ±1.5% Full Scale (Not Rated)0 to 10 psi4026K160000004026K37000000
     
    NPT Male with Calibration Certificate Traceable to NIST
    2 1/2"1/4
    Black0 to 1400 to 140Air
    Carbon Dioxide
    Hydraulic Fluid
    Natural Gas
    Water
    ±1.5% Full Scale (Not Rated)0 to 10 psi4026K240000004026K46000000
     
    304 Stainless Steel Case with Brass Connection—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Pressure Gauges. High-Accuracy Low-Pressure Gauges, Single Scale, Bottom Connection.
    Image of Attribute. Bottom Connection. Front orientation. High-Accuracy Low-Pressure Gauges, Bottom Connection.

    Bottom Connection

    Bottom

    Connection

    Gauges with 304 stainless steel case or polyester plastic case have better corrosion resistance than gauges with painted steel case.
    Temp.
    Range, ° F
    Bottom
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Process
    For Use With
    Accuracy
    Pressure
    Range
    Each
    Upright Mount
     
    NPT Male
    4"1/4
    0 to 1400 to 140Air
    Carbon Dioxide
    Hydraulic Fluid
    Natural Gas
    Water
    ±1% Full Scale (Grade 1A)0 to 10 psi4269K10000000
     
    Polyester Plastic Case with Brass Connection—Dual Scale (Pounds per Square Inch, Inches of Mercury)
    Image of Product. Front orientation. Pressure Gauges. High-Accuracy Low-Pressure Gauges, Dual Scale, Bottom Connection (Flange Mount).
    Image of Attribute. Bottom
Connection
(Flange Mount). Front orientation. High-Accuracy Low-Pressure Gauges, Bottom Connection (Flange Mount).

    Bottom Connection

    (Flange Mount)

    Bottom Connection (Flange

    Mount)

    Gauges with 304 stainless steel case or polyester plastic case have better corrosion resistance than gauges with painted steel case.
    Safety Case—Gauges with safety case blow out in the back under excess pressure, protecting the operator in front.
    Bottom Connection (Flange Mount)
    Temp.
    Range, ° F
    Mounting
    Dial
    Dia.
    Pipe
    Size
    Case
    Color
    Environment
    Process
    Features
    For Use With
    Accuracy
    Pressure Range
    Fasteners
    Included
    Hole
    Dia.
    No. of
    Holes
    Each
    Upright Mount
     
    NPT Male
    4 1/2"1/4
    Black0 to 140-40 to 210Safety CaseAir
    Argon
    Natural Gas
    Nitrogen
    ±1% Midscale (Grade A)0 to 10 psi/0 to 20 in. HgNo1/4"34221K30000000
     

    Low-Pressure Differential Gauges with Inclined Scale

    Easier to read than U-tube gauges, these use an inclined scale to measure pressure or velocity in air applications. Gauges are also known as manometers.
    Polycarbonate Connections (Inches of Water)
    Image of Product. Front orientation. Differential Pressure Gauges. Low-Pressure Differential Gauges with Inclined Scale.
    Indicating
    Liquid
    Pressure,
    in. H₂O
    Max. Pressure,
    psi
    Max. Process
    Temp., ° F
    Ht.
    Color
    Specific
    Gravity
    Mount
    Type
    Mounting Fasteners
    Included
    Includes
    For Use
    With
    Accuracy
    Each
    Male Barbed Tubes for 1/8" Tube IDs
    0 to 3101406"Red0.826Screw OnYes8-ft. Lg. Tubing, Indicating LiquidAir±3%3974K1000000
    0 to 7101406"Blue1.91Screw OnYes8-ft. Lg. Tubing, Indicating LiquidAir±3%3974K2000000
     

    Ultra-High-Accuracy Digital Pressure Test Gauges

    With an accuracy of ±0.05%, these have the highest accuracy of all our test gauges. Use them for testing, calibrating, laboratory applications, and other critical processes that require precision. They have a five-digit LCD display that allows for easy reading of measurements.
    304 Stainless Steel Case with 316 Stainless Steel Connection—Battery Powered
    Image of Product. Front orientation. Pressure Test Gauges. Ultra-High-Accuracy Digital Pressure Test Gauges.
    Image of Specification. Front orientation. Bottom Connection. Ultra-High-Accuracy Digital Pressure Test Gauges.
    Bottom
    Connection
    Pressure
    Pressure Resolution,
    psi
    Accuracy
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Enclosure
    Rating
    Hazardous Location Rating
    Features
    Digit
    Ht.
    For Use With
    Batteries
    Included
    Each
    NPT Male—Calibration Certificate Traceable to NIST
     
    3" Diameter Dial—1/4 Pipe Size
    0 psi to 10 psi
    0 in. H₂O to 270 in. H₂O
    0 kPa to 65 kPa
    0 MPa to 0.06 MPa
    0 bar to 0.6 bar
    0 kg/cm² to 0.7 kg/cm²
    0.001±0.05% Full Scale
    (Grade 5A)
    -40 to 1800 to 150IP65
    NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2
    Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never)1 1/8"Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterYes3584K11000000000
     

    Differential Pressure and Vacuum Gauges with Digital Display

    Gauges have a four-digit LCD display for easy reading of measurements. Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.
    Aluminum Case with Brass Connection—(psi, kPa, in. of H₂O, in. of Hg, mbar)
    Image of Product. Front orientation. Differential Pressure and Vacuum Gauges. Differential Pressure and Vacuum Gauges with Digital Display .
    Pressure Range
    Vacuum Range,
    in. Hg
    Pressure Resolution,
    in. H₂O
    Max. Pressure
    For Tube ID
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Digit
    Ht.
    Batteries
    Included
    Features
    For Use
    With
    Accuracy
    Each
    Barbed Fitting Connection
    0 psi to 0.723 psi
    0 psi to 10 psi
    0 kPa to 4.982 kPa
    0 in. H₂O to 20 in. H₂O
    0 mbar to 49.82 mbar
    0 to 1.4710.010.723 psi, 10 psi, 4.982 kPa, 20 in. H₂O, 49.82 mbar1/8" to 3/16"35 to 1000 to 1403/8"Yes40-Reading Memory, Overpressure AlarmAir±0.5% Full-Scale Accuracy (Not Rated)4125K410000000
     
    Barbed Fitting Connection with Calibration Certificate Traceable to NIST
    0 psi to 0.723 psi
    0 psi to 10 psi
    0 kPa to 4.982 kPa
    0 in. H₂O to 20 in. H₂O
    0 mbar to 49.82 mbar
    0 to 1.4710.010.723 psi, 10 psi, 4.982 kPa, 20 in. H₂O, 49.82 mbar1/8" to 3/16"35 to 1000 to 1403/8"Yes40-Reading Memory, Overpressure AlarmAir±0.5% Full-Scale Accuracy (Not Rated)4125K61000000
     

    High-Pressure Differential Gauges

    These gauges are able to withstand line pressures up to 3,000 pounds per square inch. They are commonly used to measure pressure differences in pumps and filters.
    Aluminum Case with Aluminum Connections—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Differential Pressure Gauges. High-Pressure Differential Gauges.
    Dial
    Dia.
    Max. Pressure,
    psi
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    For Use With
    Accuracy
    Pressure,
    psi
    Graduations,
    psi
    Pressure Numeric
    Increments, psi
    Each
    1/4 NPT Female Threaded Pipe Connection
    2 1/2"3,0000 to 1500 to 200Water, Hydraulic Fluid, Gasoline±2%0 to 100.524107K1110000000
    4 1/2"3,0000 to 1500 to 200Water, Hydraulic Fluid, Gasoline±2%0 to 100.524107K511000000
     
    316 Stainless Steel Case with 316 Stainless Steel Connections—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Differential Pressure Gauges. High-Pressure Differential Gauges.
    Gauges with 316 stainless steel case are more corrosion resistant than gauges with an aluminum case.
    Dial
    Dia.
    Max. Pressure,
    psi
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    For Use With
    Accuracy
    Pressure,
    psi
    Graduations,
    psi
    Pressure Numeric
    Increments, psi
    Each
    1/4 NPT Female Threaded Pipe Connection
    2 1/2"3,0000 to 1500 to 200Water, Hydraulic Fluid, Gasoline±2%0 to 100.524232K1110000000
    4 1/2"3,0000 to 1500 to 200Water, Hydraulic Fluid, Gasoline±2%0 to 100.524232K511000000
     

    Differential Pressure Transmitters with Dial Indicator for Air

    Check the difference in air pressure between two inputs at the source using the dial indicator or remotely using a receiver. The dial indicator on these transmitters operates independently and shows differential pressure in real time for troubleshooting. Also known as transducers, these transmitters convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are CE marked, so they meet European safety standards.
    When measuring pressure in ductwork, pair them with a static pressure probe.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Aluminum HousingAbout Aluminum Housing
    Image of Product. Front orientation. Differential Pressure Transmitters. Differential Pressure Transmitters with Dial Indicator for Air.
    Connection
    Pressure Differential,
    in. H₂O
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    For No.
    of Wires
    Mounting Hardware
    Included
    No. of Mounting
    Holes
    Dia.
    Certification
    For Use
    With
    Accuracy
    Pipe
    Fitting
    Material
    Temp. Range,
    ° F
    Each
    4 to 20 mA Output Signal—Screw Terminals
    0 to 0.51010 to 351/8
    2No35 1/2"CE Marked
    Air±2%NPT FemaleThreaded
    Aluminum
    20 to 12038525K1110000000
    0 to 11010 to 351/8
    2No35 1/2"CE Marked
    Air±2%NPT FemaleThreaded
    Aluminum
    20 to 12038525K112000000
    0 to 61010 to 351/8
    2No35 1/2"CE Marked
    Air±2%NPT FemaleThreaded
    Aluminum
    20 to 12038525K217000000
     

    Low-Pressure Differential Gauges with Digital Display

    Measure small changes in air pressure with these hand-held gauges. They have a four-digit LCD display for easy reading of measurements. Gauges are commonly used to indicate clogged filters and to monitor fans and blowers.
    Aluminum Case with Nickel-Plated Brass Connections (Kilopascals, Inches of Water)
    Image of Product. Front orientation. Differential Pressure Gauges. Low-Pressure Differential Gauges with Digital Display.
    Gauges
    Nylon
    Carrying Cases
    Pressure
    Range
    Pressure
    1, kPa
    Pressure
    2, in. H₂O
    Pressure Resolution,
    in. H₂O
    Max. Pressure,
    psi
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Digit
    Ht.
    Ht.
    Wd.
    Batteries
    Included
    For Use With
    Accuracy
    Hazardous Location Rating
    Each
    Each
    Male Barbed Tubes for 1/8" to 3/16" Tube IDs
    0 to 4.9820 to 200.011035 to 1000 to 1403/8"6 1/2"2 13/16"YesAir, Natural Gas±0.5%NEC Class I Division 2 Groups A, B, C, D
    4125K2100000004125K11000000
     
    Male Barbed Tubes for 1/8" to 3/16" Tube IDs with Calibration Certificate Traceable to NIST
    0 to 4.9820 to 200.011035 to 1000 to 1403/8"6 1/2"2 13/16"YesAir, Natural Gas±0.5%NEC Class I Division 2 Groups A, B, C, D
    4125K510000004125K1100000
     

    Differential Pressure Transmitters with Digital Display for Air

    With a digital display and selectable differential pressure ranges, these transmitters are a versatile alternative to transmitters with dial indicators. Unlike a standard transmitter that has one wider differential pressure range, these transmitters have multiple ranges to choose from. The selectable pressure range means they are more accurate than standard transmitters since their accuracy applies to each small range rather than a single wide range. They can also be configured to output either current or voltage, while standard transmitters typically output one signal type. The digital display allows you to troubleshoot and monitor differential pressure at the source. Also known as transducers, they measure the difference in pressure between two inputs and convert it to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are rated UL 94 V-0, so they meet flammability standards. CE marked, they also meet European safety standards.
    When measuring pressure in ductwork, pair them with a static pressure probe. Transmitters with an 8" pressure probe cable include a static pressure probe.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    Connect them using two wires when using the current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. For voltage output, connect them using three wires—two wires into the power supply and a separate wire to send a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Polycarbonate HousingAbout Polycarbonate Housing
    Image of Product. Front orientation. Contains Annotated. Differential Pressure Transmitters. Differential Pressure Transmitters with Digital Display for Air, Polycarbonate Housing.
    DIN-Rail/Surface Mount—DIN-rail/surface mount transmitters give you mounting flexibility. They include the bracket you'll need for mounting it to DIN rail.
    Calibration Certificate Traceable to NIST—Transmitters with a calibration certificate traceable to NIST have passed tests for accuracy.
    IP67 Enclosure Rating—Transmitters that meet IP67 protect against dust and submersion.
    Mounting
    Holes
    Connection
    Calibration
    Certificate Traceable to NIST
    Pressure Differential
    Range
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    For Tube
    ID
    For DIN
    Rail Ht., mm
    For No.
    of Wires
    Mounting Hardware
    Included
    Dia.
    No.
    of
    Ht.
    Wd.
    Certification
    Pressure
    Probe Cable Lg.
    Enclosure
    Rating
    For Use
    With
    Accuracy
    Fitting
    Material
    Temp. Range,
    ° F
    Each
    4 to 20 mA, 0 to 5V DC, 0 to 10V DC Output Signal—Screw Terminals
     
    Surface Mount
    -5 to 5 in. H₂O
    -2.5 to 2.5 in. H₂O
    -1 to 1 in. H₂O
    -0.5 to 0.5 in. H₂O
    0 to 0.5 in. H₂O
    0 to 1 in. H₂O
    0 to 2.5 in. H₂O
    0 to 5 in. H₂O
    1013 to 303/16"2, 3No3/16"25 7/16"3 3/16"CE Marked
    IP67
    Air±1%Barbed
    Brass32 to 1223264N210000000
     
    DIN-Rail/Surface Mount
    -5 to 5 in. H₂O
    -2.5 to 2.5 in. H₂O
    -1 to 1 in. H₂O
    -0.5 to 0.5 in. H₂O
    0 to 0.5 in. H₂O
    0 to 1 in. H₂O
    0 to 2.5 in. H₂O
    0 to 5 in. H₂O
    1013 to 303/16"352, 3No3/16"25 7/16"3 3/16"CE Marked
    8"IP67
    Air±1%Barbed
    Brass32 to 1223264N22000000
     

    Medium-Pressure Differential Gauges

    Popular for use with natural gas, these gauges measure pressure differences in pipelines and filters with a maximum pressure of 1,500 pounds per square inch.
    Aluminum Case with Aluminum Connections—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Differential Pressure Gauges. Medium-Pressure Differential Gauges.
    Dial
    Dia.
    Max. Pressure,
    psi
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    For Use With
    Accuracy
    Pressure,
    psi
    Graduations,
    psi
    Pressure Numeric
    Increments, psi
    Each
    1/4 NPT Female Threaded Pipe Connection
    2 1/2"1,5000 to 1500 to 200Water, Hydraulic Fluid, Gasoline, Natural Gas±2%0 to 100.524028K1160000000
    4 1/2"1,5000 to 1500 to 200Water, Hydraulic Fluid, Gasoline, Natural Gas±2%0 to 100.524028K316000000
     
    316 Stainless Steel Case with 316 Stainless Steel Connections—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Differential Pressure Gauges. Medium-Pressure Differential Gauges.
    Gauges with 316 stainless steel case are more corrosion resistant than gauges with an aluminum case.
    Dial
    Dia.
    Max. Pressure,
    psi
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    For Use With
    Accuracy
    Pressure,
    psi
    Graduations,
    psi
    Pressure Numeric
    Increments, psi
    Each
    1/4 NPT Female Threaded Pipe Connection
    2 1/2"1,5000 to 1500 to 200Water, Hydraulic Fluid, Gasoline, Natural Gas±2%0 to 100.524028K4160000000
    4 1/2"1,5000 to 1500 to 200Water, Hydraulic Fluid, Gasoline, Natural Gas±2%0 to 100.524028K616000000
     

    Submersible Liquid-Level Transmitters

    Image of Product. Front orientation. Liquid-Level Transmitters. Submersible Liquid-Level Transmitters, For Liquids.
    Image of Product. Top orientation. Liquid-Level Transmitters. Submersible Liquid-Level Transmitters, For Liquids with Solids.

    For Liquids

    For

    Liquids

    with

    Solids

    Best for measuring liquid levels in applications where traditional mounting is difficult, these transmitters sit at the bottom of your tank. They sense liquid levels by measuring the pressure from the weight of the liquid above them. These transmitters continuously send measurements, so you can monitor the status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
    For Liquids with Solids—Transmitters for liquids with solids have sink weights that keep the transmitter in place in applications with moving solids or agitated liquids.
    Overall
    For Pressure
    Accuracy
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    For Container Type
    Electrical
    Connection
    Enclosure
    Rating
    Each
    4 mA to 20 mA Output Current
     
    For Liquids
    0 to 10 psi / 0 to 23 ft. H₂O±0.5%15 psi @ 70° F1"5 5/8"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N120000000
     
    For Liquids with Solids
    0 to 10 psi / 0 to 23 ft. H₂O±0.5%15 psi @ 70° F3 1/4"5 1/4"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N16000000
     

    Compact Compressed Air Regulators

    A lower profile than our other compressed air regulators makes these regulators a better fit in tight spots. Use them to adjust and maintain the pressure of your compressed air. Install them in your air line after filters.
    Relieving with Gauge Included
    Image of Product. Front orientation. Compressed Air Regulators. Compact Compressed Air Regulators, Relieving with Gauge Included.
    Relieving regulators exhaust when the downstream pressure exceeds the set pressure.
    Mounting Brackets—Mounting brackets (sold separately) allow you to attach the regulator to a wall or equipment.
    Regulators
    Mounting
    Brackets
    Pipe
    Size
    Overall
    Inlet
    Outlet
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Housing
    Material
    Wd.
    Ht.
    Max. Temp.,
    ° F
    Regulating
    Accuracy
    Pressure Regulation,
    psi
    Each
    Each
    NPT Female Inlet × NPT Female Outlet
    1/8
    1/8
    14 scfm @ 100 psi300Zinc Alloy1 5/8"3"150±3 psi1 to 109892K110000009891K66000000
    1/4
    1/4
    15 scfm @ 100 psi300Zinc Alloy1 5/8"3"150±3 psi1 to 109892K12000009891K6600000
     
    BSPP Female Inlet × BSPP Female Outlet
    1/8
    1/8
    14 scfm @ 100 psi300Zinc Alloy1 5/8"3"150±3 psi1 to 106746K93000009891K6600000
    1/4
    1/4
    15 scfm @ 100 psi300Zinc Alloy1 5/8"3"150±3 psi1 to 106746K94000009891K6600000
     

    High-Accuracy Differential Pressure Transmitters

    At least twice as accurate as standard transmitters, these transmitters sense differential pressure at an accuracy of ±0.25%. Use them in laboratories or testing applications where the difference in pressure between two points needs to be measured with high accuracy. These transmitters are often used to indicate a filter is clogged or help you maintain a certain pressure in pumps, HVAC, cooling, and other air and liquid systems. They convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. All transmitters are rated NEMA 4 for protection in washdown environments.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. As the differential increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Aluminum HousingAbout Aluminum Housing
    Image of Product. Front orientation. Contains Annotated. Differential Pressure Transmitters. High-Accuracy Differential Pressure Transmitters.
    Mounting
    Holes
    Connection
    Pressure Differential,
    psi
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    For No.
    of Wires
    Mounting Hardware
    Included
    Dia.
    No.
    of
    Ht.
    Wd.
    Enclosure
    Rating
    For Use
    With
    Accuracy
    Pipe
    Fitting
    Material
    Temp. Range,
    ° F
    Each
    4 to 20 mA Output Signal—Screw Terminals
    0 to 103509 to 301/4
    2Yes5/32"43 1/8"2 7/16"NEMA 4
    Air, Water±0.25%NPT FemaleThreaded
    17-4 PH Stainless Steel
    0 to 1759917K54000000000
     

    Differential Pressure Transmitters for Liquids

    Used with pumps, cooling systems, and other liquid applications, these transmitters remotely measure the difference in pressure between two inputs. They are also known as transducers. These transmitters convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. You’ll often see them used to indicate a filter is clogged.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    316 Stainless Steel HousingAbout 316 Stainless Steel Housing
    Image of Product. Front orientation. Contains Annotated. Differential Pressure Transmitters. Differential Pressure Transmitters for Liquids, 316 Stainless Steel Housing.
    IP66 Enclosure Rating— IP66 rated transmitters are dust tight and protect against washdowns.
    NEMA 4X Enclosure Rating—NEMA 4X rated transmitters protect against weather, washdowns, and corrosion.
    Mounting
    Holes
    Connection
    Pressure Differential,
    psi
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    For No.
    of Wires
    Mounting Hardware
    Included
    Dia.
    No.
    of
    Ht.
    Wd.
    Certification
    Enclosure
    Rating
    For Use With
    Accuracy
    Pipe
    Fitting
    Material
    Temp. Range,
    ° F
    Each
    4 to 20 mA Output Signal—Screw Terminals
    0 to 105010 to 351/4
    2No1/4"22"1 7/16"CE Marked
    IP66, NEMA 4X
    Diesel Fuel, Gasoline, Hydraulic Fluid, Water±0.5%NPT FemaleThreaded
    316 Stainless Steel
    0 to 2003257N120000000
     

    Horizontal-Mount Fuel-Level Gauges for Tanks

    Image of Product. Front orientation. Liquid-Level Gauges. Horizontal-Mount Fuel-Level Gauges for Tanks.
    Mount these gauges on the flat end of a horizontal, cylindrical tank to monitor diesel fuel, fuel oil, or gasoline level. They are UL listed for flammable liquids. For shallower tanks, cut the rod ½” to 1” shorter than your tank depth to prevent it from touching the bottom.
    1 1/4 NPT Male
    Thread
    1 1/2 NPT Male
    Thread
    For Tank
    Dp.
    Dial
    Dia.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    For Container
    Type
    Float
    Material
    Dial
    Material
    Numeric
    Graduations
    Features
    Each
    Each
    Aluminum Float Rod
    21 1/2"2 5/16"10-40 to 155Open TankBuna-N
    Zinc Alloy1/4Plastic Lens3717K660000003717K67000000
     