Strain Gauges
Glue these gauges onto a structure to measure strain in a single direction. They’re often used in structural testing and monitoring applications. Strain is the deformation or displacement of material caused by force.
Solder wire leads onto gauges with solder terminals after the gauge has bonded to your surface. After soldering, apply a protective coating.
Gauges with wire leads save you the effort of soldering wire to the gauge and checking to see that it’s bonded securely.
For technical drawings and 3-D models, click on a part number.



Grid | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Resistance, ohms | Accuracy | Length | Width | Length | Width | Wire Lead Length, ft. | Material | Temperature Range, °F | Pkg. Qty. | Pkg. | |
Solder Terminals | |||||||||||
For Use With Cast Iron, Composites, Printed Circuit Board, Steel | |||||||||||
350 | ±0.2% | 0.125" | 0.1" | 0.275" | 0.12" | __ | C70600 Copper Nickel | -100° to 350° | 5 | 0000000 | 000000 |
Two Wire Leads | |||||||||||
For Use With Aluminum, Brass, Tin | |||||||||||
120 | ±0.3% | 0.235" | 0.1" | 0.301" | 0.1" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
350 | ±0.3% | 0.06" | 0.1" | 0.166" | 0.13" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
350 | ±0.3% | 0.235" | 0.1" | 0.301" | 0.1" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
For Use With Cast Iron, Composites, Printed Circuit Board, Steel | |||||||||||
120 | ±0.3% | 0.06" | 0.1" | 0.166" | 0.13" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
120 | ±0.3% | 0.125" | 0.1" | 0.205" | 0.1" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
120 | ±0.3% | 0.235" | 0.1" | 0.301" | 0.1" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
350 | ±0.3% | 0.06" | 0.1" | 0.166" | 0.13" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
350 | ±0.3% | 0.125" | 0.1" | 0.205" | 0.1" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
For Use With Composites, Nickel Iron, Titanium Silicate | |||||||||||
350 | ±0.3% | 0.235" | 0.1" | 0.301" | 0.1" | 3 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
Three Wire Leads | |||||||||||
For Use With Aluminum, Brass, Tin | |||||||||||
350 | ±0.2% | 0.03" | 0.063" | 0.095" | 0.063" | 3 | Nickel Chromium | -100° to 400° | 1 | 0000000 | 00000 |
For Use With Cast Iron, Composites, Printed Circuit Board, Steel | |||||||||||
350 | ±0.2% | 0.03" | 0.063" | 0.095" | 0.063" | 9 | Nickel Chromium | -100° to 400° | 1 | 0000000 | 00000 |
350 | ±0.3% | 0.06" | 0.1" | 0.166" | 0.13" | 9 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |
For Use With Composites, Nickel Iron, Titanium Silicate | |||||||||||
350 | ±0.3% | 0.235" | 0.1" | 0.301" | 0.1" | 9 | C70600 Copper Nickel | -60° to 180° | 10 | 0000000 | 000000 |

Container | |||||||||
---|---|---|---|---|---|---|---|---|---|
Size, fl. oz. | Type | Begins to Harden | Reaches Full Strength | Consistency (Viscosity) | Temperature Range, °F | For Use On | Includes | Each | |
1 | Bottle | 1 min. | 5 min. | Thin Liquid (130 cP) | -25° to 150° | Aluminum, Composites, Glass, Steel | Catalyst | 0000000 | 000000 |

Width | Length, ft. | Color | Temperature Range | Features | Each | |
3/4" | 216 | Clear | 400° F | Tape Dispenser | 0000000 | 0000000 |

Dry Time | |||||
---|---|---|---|---|---|
Container Size, fl. oz. | Touch, min. | Overall, hrs. | Pkg. Qty. | Pkg. | |
1 | 20 | 2 | 4 | 0000000 | 000000 |
Thermistor Sensors

Quickly and accurately check the temperature of electronics and appliances. As the temperature of your device rises, the resistance of these NTC (negative temperature coefficient) sensors decreases. They work best with small temperature changes and temperatures similar to the ambient air. They’re not as accurate as RTD probes for high heat and wide temperature swings.
Pair these sensors with a temperature controller to maintain the ideal temperature of your device.
Lead | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range, °F | Resistance, ohms | Diameter | Height | Diameter | Length | No. of | Accuracy | Response Time, sec. | Thermal Time Constant, sec. | Connection Type | Wattage, mW | B Value, K | Material | Pkg. Qty. | Pkg. | |
-40° to 250° | 100 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 3,100 | Epoxy Resin | 5 | 00000000 | 00000 |
-40° to 250° | 200 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 3,100 | Epoxy Resin | 5 | 00000000 | 0000 |
-40° to 250° | 1,000 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 3,800 | Epoxy Resin | 5 | 00000000 | 0000 |
-40° to 250° | 3,000 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 3,900 | Epoxy Resin | 5 | 00000000 | 0000 |
-40° to 250° | 5,000 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 3,900 | Epoxy Resin | 5 | 00000000 | 0000 |
-40° to 250° | 10,000 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 3,434 | Epoxy Resin | 5 | 00000000 | 0000 |
-40° to 250° | 10,000 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 4,100 | Epoxy Resin | 5 | 00000000 | 0000 |
-40° to 250° | 50,000 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 4,200 | Epoxy Resin | 5 | 00000000 | 0000 |
-40° to 250° | 100,000 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 4,400 | Epoxy Resin | 5 | 00000000 | 0000 |
-40° to 250° | 200,000 | 1/4" | 1/8" | 0.098" | 1" | 2 | ±10% | 0.025 | 15 | Wire Leads | 450 | 4,500 | Epoxy Resin | 5 | 00000000 | 0000 |
Electrical Resistance Testers for Static Control



Check that your material and work surfaces won’t discharge static electricity, which can damage sensitive electronics. These testers are designed to take measurements in accordance with ANSI guidelines for electrostatic discharge control. They measure electrical resistance up to 1×1012 ohms—five orders of magnitude greater than our multimeters.
These testers measure resistance between two points on a surface and from the surface to a ground. To avoid a sudden release of static, resistance should be between 1×106 and 1×109 ohms.
Use the small parts probe (sold separately) to measure resistance on small items or in hard-to-access areas. Use the packaging probe (sold separately) to measure resistance of thin packaging and films.
Batteries | ||||||||
---|---|---|---|---|---|---|---|---|
Resistance, ohms | Accuracy | Features | Includes | Included | Size | No. Required | Each | |
1×103-1×1012 | ±10% | Battery Life Indicator, Data Memory | 1 Alligator Clip, 1 Carrying Case, 1 Ground Plug Adapter, 2 Probe Spacers (10" Lg. and 36" Lg.), 2 Test Leads, 2 Test Probes | Yes | AA | 4 | 000000 | 000000000 |