Spade-Terminal Relays
Using a low-current signal, these relays are often used to control small motors and heaters. These relays attach to quick-disconnect terminals.
Surface mount relays, also known as power relays, have a slot on the flange for mounting them to flat surfaces.
Relay-socket mount relays, also known as ice cube relays, offer three ways to connect. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals.
Relay-socket/surface mount relays can plug into a socket or mount to a flat surface.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They can also mount to a flat surface.




Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
5 | 24V AC | 84 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 000000 | 0000000 | 000000 |
5 | 120V AC | 18 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
5 | 240V AC | 9 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
5 | 12V DC | 100 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
5 | 24V DC | 51 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 12V AC | 168 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V AC | 84 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 18 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 9 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 12V DC | 100 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 51 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V DC | 11 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 12V AC | 230 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 000000 | 0000000 | 00000 |
11 | 24V AC | 115 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 24 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 12 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 100 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 51 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |



With Screw
Terminals
Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
8 | 24V AC | 46 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 000000 | 0000000 | 000000 |
8 | 120V AC | 9 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 37 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 24V AC | 46 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 9 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 37 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 24V AC | 67 | 250V AC | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 59 | 250V AC | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |



Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
4 | 24V AC | 71 | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 000000 |
4 | 120V AC | 20 | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
4 | 240V AC | 10 | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||
5 | 24V AC | 37 | 380V AC | 1/3 hp @ 120 V AC | 0.6" | 1.8" | 1.16" | 0.187" | 0000000 | 00000 |
5 | 24V DC | 21 | 380V AC | 1/3 hp @ 120 V AC | 0.6" | 1.8" | 1.16" | 0.187" | 0000000 | 0000 |
5 | 120V AC | 7 | 380V AC | 1/3 hp @ 120 V AC | 0.6" | 1.8" | 1.16" | 0.187" | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||
6 | 12V DC | 158 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 24V AC | 71 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 24V DC | 79 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 120V AC | 20 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 240V AC | 10 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
Compact Spade-Terminal Relays






Fit these relays where standard spade-terminal relays are too big. You can connect them three ways. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals. An LED indicator shows you the status of the relay, so you know it’s connected and wired correctly.
Relays that control 2 or more circuits have a lockable test button, so you can test their function. When you press the button, the relay switches contacts. Use this button when checking a relay for proper function before installing it, or when investigating issues with wired relays.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. You can also mount them to a flat surface using screws.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Maximum Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
8 | 24V AC | 46 | 15 A @ 120 V AC/24 V DC | 250V AC | 1.1" | 0.9" | 1.6" | 0.197" | 00000000 | 000000 | 0000000 | 000000 |
8 | 120V AC | 9 | 15 A @ 120 V AC/24 V DC | 250V AC | 1.1" | 0.9" | 1.6" | 0.197" | 00000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 37 | 15 A @ 120 V AC/24 V DC | 250V AC | 1.1" | 0.9" | 1.6" | 0.197" | 00000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
8 | 24V AC | 50 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
8 | 24V AC | 50 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 10 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 10 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 240V AC | 5 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 5 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 75 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 92 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 38 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 46 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
11 | 24V AC | 63 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 13 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 6 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 117 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 58 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open) or 4 On (Normally Closed)—4PDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
14 | 24V AC | 50 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
14 | 24V AC | 63 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 120V AC | 10 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
14 | 120V AC | 13 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 240V AC | 5 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
14 | 240V AC | 6 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 12V DC | 92 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
14 | 12V DC | 125 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 24V DC | 6 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 24V DC | 46 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
Thin Spade-Terminal Relays



with Screw
Terminals

Spring-Clamp
Terminals
Save space in your control cabinet. These narrow relays are often used for low-current switching applications, such as on small motors and pilot lights. They plug into a socket (sold separately) for quick installation.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail). Those with screw terminals connect and disconnect wire when you turn the screws. They can also mount to a flat surface. Those with spring-clamp terminals connect and disconnect to wires without needing to turn screws. Insert a screwdriver into the slot to release the spring clamp holding the wire in place.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets with Screw Terminals | Relay Sockets with Spring-Clamp Terminals | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Maximum Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
Relay-Socket Mount | ||||||||||||||
5 | 24V AC | 44 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
5 | 120V AC | 8 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 240V AC | 4 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 6V DC | 87 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 12V DC | 43 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 24V DC | 22 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 48V DC | 11 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 0000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
Relay-Socket Mount | ||||||||||||||
8 | 24V AC | 44 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 8 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 4 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 6V DC | 87 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 12V DC | 43 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 22 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Solid State Spade-Terminal Relays
Often used for high-speed switching at low-current levels, these solid state relays have no moving parts, so they switch faster, last longer, and are quieter than mechanical switches.
Heat sinks disperse heat to increase the relay’s current rating. Mount to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They also mount to flat surfaces.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
Relay sockets with screw terminals can also mount to a flat surface.


Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ 240V AC | Quick-Disconnect Tab Wd. | Heat Sinks | |||||||||||
Number of Terminals | Input Voltage | Without Heat Sink | With Heat Sink | Max. Switching Voltage | Ht. | Wd. | Dp. | Control Terminal | Load Terminal | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||
4 | 5V DC | 5A | __ | 240V AC | 1.9" | 1.5" | 0.9" | 0.11" | 0.25" | 00000000 | 000000 | 000000 | 00 |
4 | 5V DC | 5A | 10A | 240V AC | 1.9" | 1.5" | 0.9" | 0.11" | 0.25" | 00000000 | 00000 | 0000000 | 000000 |
4 | 12V DC | 5A | __ | 240V AC | 1.9" | 1.5" | 0.9" | 0.11" | 0.25" | 00000000 | 00000 | 000000 | 00 |
4 | 12V DC | 5A | 10A | 240V AC | 1.9" | 1.5" | 0.9" | 0.11" | 0.25" | 00000000 | 00000 | 0000000 | 00000 |
4 | 24V DC | 5A | __ | 240V AC | 1.9" | 1.5" | 0.9" | 0.11" | 0.25" | 00000000 | 00000 | 000000 | 00 |
4 | 24V DC | 5A | 10A | 240V AC | 1.9" | 1.5" | 0.9" | 0.11" | 0.25" | 00000000 | 00000 | 0000000 | 00000 |


with Screw
Terminals
DIN-Rail Mount Interface Relays






Isolate input and output circuits to prevent damage from voltage spikes, reduce signal interference, and amplify signal. These relays interface between your controller and components—they receive a signal from the controller to switch power on or off to the components. All have an LED indicator that shows you if your switch is actuated, so you know it’s connected and wired correctly. Use them to communicate signals to devices like motors or sensors. Mount them on 35 mm DIN rail (also known as DIN 3 rail).
Relays with spring-clamp terminals connect and disconnect to wires without needing to turn screws. Because there is no screw, these connections have less risk of loosening over time than screw terminals, even when there is vibration.
Relays with a fuse holder slot give you the option for additional overload protection. If the current exceeds the fuse’s rating, the fuse will blow and break the circuit. This prevents the relay from overheating, breaking, or causing a fire. The fuse holder is sold separately. You can use these relays without the fuse holder as a standard interface relay.
Relays with PLC output protection prevent voltage spikes created by the relay from damaging the output channel on your programmable logic controller (PLC).
For technical drawings and 3-D models, click on a part number.
Relays with Relay Sockets | Replacement Relays | Fuse Holders | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
With Screw Terminals | ||||||||||||||
5 | 24V AC | 45 | 16A | 1/3 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
5 | 120V AC | 8 | 16A | 1/3 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 00000 | 000000 | 00 |
5 | 24V AC, 24V DC | 11 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 00000 |
5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 240V DC | 19 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 120V AC, 120V DC | 5 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 24V DC | 20 | 16A | 1/3 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 0000 | 000000 | 00 |
With Spring-Clamp Terminals | ||||||||||||||
5 | 24V AC, 24V DC | 11 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 240V DC | 19 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 120V AC, 120V DC | 5 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
With Screw Terminals | ||||||||||||||
8 | 24V AC | 45 | 8A | 1/4 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 00000 | 000000 | 00 |
8 | 120V AC | 8 | 8A | 1/4 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 00000 | 000000 | 00 |
8 | 24V DC | 20 | 8A | 1/4 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 0000 | 000000 | 00 |
With Spring-Clamp Terminals | ||||||||||||||
8 | 120V AC | 12 | 10A | 1/3 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
8 | 24V DC | 40 | 10A | 1/3 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||||
With Screw Terminals | ||||||||||||||
11 | 24V AC | 53 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
11 | 120V AC | 12 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
11 | 12V DC | 86 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
11 | 24V DC | 40 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
4 Circuits Controlled with 4 Off (Normally Open) or 4 On (Normally Closed)—4PDT | ||||||||||||||
With Screw Terminals | ||||||||||||||
14 | 24V AC | 53 | 7A | 1/8 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 120V AC | 12 | 7A | 1/8 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 12V DC | 86 | 7A | 1/8 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 24V DC | 40 | 7A | 1/8 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
With Spring-Clamp Terminals | ||||||||||||||
14 | 24V AC | 53 | 7A | 1/8 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 12V DC | 86 | 7A | 1/8 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 24V DC | 40 | 7A | 1/8 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
Solid State High-Starting-Current Vehicle Relays


Crimp-On
Terminals

With no moving parts, these solid state relays require less maintenance and last longer, switch faster, and are quieter than mechanical relays. They can handle high starting (inrush) currents. The blade terminals meet ISO 8092-1 dimensions, ensuring they are compatible with the electrical connections in road vehicles you need to maintain or repair. Also known as ISO relays or automotive relays.
Relays | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Switching Current @ 12V DC | Max. Switching Voltage | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||||
4 | 12V DC | 20A | 16V DC | 80 | 10 | 1.1" | 1.1" | 1" | 0.25" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
Weatherproof High-Starting-Current Vehicle Relays




Crimp-On
Terminals
An extended housing shields the terminals on these relays from weather. They're also rated IP54—when they're plugged into the relay socket, they're sealed to keep splashing water, like rain, from getting inside. They handle high starting (inrush) currents that often occur when turning on a vehicle. To prevent damage to sensitive equipment, these relays will partially suppress a momentary surge in voltage when the relay switches off. They’ll take a voltage spike of 300V to 500V and bring it down to 100V.
Relays for surface mounting have a tab for added security in high-vibration applications.
Relays | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | ||||||||||||||
Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Max. Switching Voltage | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
For Relay Socket | ||||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
5 | 12V DC | 40 A @ 12 V DC | 20 A @ 12 V DC | 18V DC | 150 | 114 | 1.4" | 1.4" | 1.8" | 0.11" | 00000000 | 000000 | 000000 | 00 | 00000000 | 000000 |
5 | 12V DC | 40 A @ 12 V DC | 20 A @ 12 V DC | 18V DC | 150 | 155 | 1.4" | 1.4" | 1.8" | 0.25" | 00000000 | 00000 | 0000000 | 000000 | 0000000 | 00000 |
For Relay Socket and Surface Mounting | ||||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
5 | 12V DC | 40 A @ 12 V DC | 20 A @ 12 V DC | 18V DC | 150 | 114 | 1.4" | 1.4" | 1.8" | 0.11" | 00000000 | 00000 | 000000 | 00 | 00000000 | 00000 |
5 | 12V DC | 40 A @ 12 V DC | 20 A @ 12 V DC | 18V DC | 150 | 138 | 1.4" | 1.4" | 1.8" | 0.25" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
5 | 24V DC | 20 A @ 24 V DC | 10 A @ 24 V DC | 40V DC | 120 | 107 | 1.4" | 1.4" | 1.8" | 0.25" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
High-Starting-Current Vehicle Relays


Relay Socket and
Surface Mounting



Crimp-On
Terminals
Also known as automotive relays, these relays can handle high starting (inrush) currents.
Relays for surface mounting have a tab for added security in high-vibration applications.
Relays | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | ||||||||||||||
Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Max. Switching Voltage | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
For Relay Socket | ||||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||||||
5 | 24V DC | 20 A @ 24 V DC | __ | 40V DC | 120 | 69 | 1" | 1" | 0.9" | 0.25" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 18V DC | 150 | 138 | 1.02" | 1.02" | 0.94" | 0.25" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 00000 |
5 | 24V DC | 20 A @ 24 V DC | 10 A @ 24 V DC | 36V DC | 150 | 99 | 1" | 1" | 1" | 0.25" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 00000 |
For Relay Socket and Surface Mounting | ||||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||||||
4 | 12V DC | 50 A @ 12 V DC | __ | 18V DC | 150 | 138 | 1.2" | 1" | 1" | 0.25" and 0.375" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 00000 |
4 | 24V DC | 70 A @ 24 V DC | __ | 40V DC | 200 | 75 | 1.5" | 1.4" | 1" | 0.25" and 0.375" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 00000 |
5 | 12V DC | 40 A @ 12 V DC | __ | 20V DC | 150 | 141 | 1" | 1" | 0.9" | 0.25" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 00000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 18V DC | 150 | 138 | 1.1" | 1.1" | 1" | 0.25" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 00000 |
5 | 24V DC | 20 A @ 24 V DC | 10 A @ 24 V DC | 40V DC | 120 | 109 | 1" | 1" | 0.9" | 0.25" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 00000 |
Latching Relays




A single, momentary input voltage switches these relays and latches them in position, so they don't require a constant input voltage to stay switched. A second momentary voltage will release the latch.
Relay sockets (sold separately) mount to 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
Relays | Relay Sockets | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC/24V DC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
9 | 24V AC | 70 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 000000 | 0000000 | 000000 |
9 | 120V AC | 14 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
9 | 12V DC | 100 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
9 | 24V DC | 50 | 10A | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
10 | 24V AC | 27 | 3A | __ | 1.1" | 0.8" | 1.4" | 0.102" | 0000000 | 000000 | 0000000 | 00000 |
10 | 12V DC | 110 | 3A | __ | 1.1" | 0.8" | 1.4" | 0.102" | 0000000 | 00000 | 0000000 | 00000 |
10 | 24V DC | 52 | 3A | __ | 1.1" | 0.8" | 1.4" | 0.102" | 0000000 | 00000 | 0000000 | 00000 |