    10 Products

    Ground-Fault Monitoring Relays

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals.
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals, Knob Adjustment.

    Screw Terminals

    Screw Terminals

    Knob Adjustment

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals with IO Link.
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Spring-Clamp Terminals with IO Link.

    Screw Terminals with

    IO Link

    Spring-Clamp

    Terminals with IO

    Link

    Detect and mitigate ground faults to prevent harm to equipment, circuits, and people. These relays monitor the differential between incoming and outgoing current, also known as residual current. When the balance is off, they trip and cut power to the circuit. These relays are highly sensitive, so you can trust them to de-energize faulty circuits before a minor issue becomes a major one. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    These relays require a current-indicating ring (sold separately) to operate. Choose a ring that is large enough for your lines to pass through. Feed the lines of the circuit through the center of the ring and connect the indicating ring output to the relay.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because they don’t have screws, there’s less of a risk that they will loosen over time, even when they’re under vibration.
    IO Link Communication Protocol—Relays with IO link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    Knob Adjustment—Relays with knob adjustments have knobs right on the front where you can set your trip current.
    LED Indicator—Relays with an LED indicator show the status of your relay, so you know it is wired correctly and when it is actuated.
    No. of
    Terminals
    Input Voltage
    Trip Current
    Setting, amp
    Trip Current,
    amp
    Trip Time,
    sec.
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw Terminals
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    1224V AC, 48V AC, 120V AC, 240V AC0.0305 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    3.2"1.4"2.6"LED Indicator8121N1010000000
    1224V AC, 48V AC, 120V AC, 240V AC0.305 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    3.2"1.4"2.6"LED Indicator8121N102000000
    1224V AC, 48V AC, 120V AC, 240V AC0.03 to 50 to 55 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    Knob3.2"1.4"2.8"LED Indicator8121N103000000
    1224V AC, 48V AC, 120V AC, 240V AC0.3 to 300 to 55 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    Knob3.2"1.4"2.8"LED Indicator8121N104000000
     
    Screw Terminals with IO Link
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    1224V DC0.03 to 400 to 9993 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad4"0.9"3.6"Remote Reset8121N109000000
     
    Spring-Clamp Terminals with IO Link
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    1224V DC0.03 to 400 to 9993 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad4.1"0.9"3.6"Remote Reset8121N111000000
     
    Current Indicating Rings