Choosing a Proximity Switch
More
Choosing an Electrical Switch
More
Frame-Mounted Safety Switches

Also known as interlock switches, these ensure the safety of personnel by automatically shutting off power to machinery when an access door opens. Mount the switch to the door frame and mount a key to the door so that the key is inserted into the switch when the door is closed. When the door opens, the key is removed from the switch and the machine shuts down. They’re often used with machine guards for large robots.
All switches require an actuator key, but not all include one—check whether you need to pick out a separate actuator key. For some switch styles, you can also select the mounting orientation of the key. Flexible keys pivot at least 15°, making them easier to align with switches during installation.
Style A-G switches have positive-force, normally closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick.
Style J switches have extra safety controls to prevent you from getting trapped next to running machinery. They actuate with the turn of a portable key. Bring the key when you enter an enclosure to ensure machinery won’t start while you’re inside, even if the door closes behind you. As an added fail-safe, a rear release button lets you cut power from inside of enclosures if needed. These switches have light-up indicators that show when they're properly installed and whether they're actuated.
IP67 rated switches protect against temporary submersion. NEMA 4 rated switches protect against washdowns. NEMA 6 rated switches protect against both temporary submersion and washdowns.






Housing | Conduit | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Ht. | Wd. | Dp. | Trade Size | Thread Size | Thread Type | Key Included | Environmental Rating | Each | |
Wire Lead Connection with Positive-Force Normally Closed Contacts | |||||||||||||||||
| A | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | DPST-1NO/1NC | 8 A @ 120 V AC, 4 A @ 24 V DC | 250V AC 24V DC | 3.3" | 1.2" | 1.2" | __ | M16 | Metric | Yes | IP67 | 00000000 | 0000000 |
Screw Terminal Connection with Positive-Force Normally Closed Contacts | |||||||||||||||||
| B | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 3" | 1" | 1.1" | 1/2 | __ | NPT | Yes | IP67, NEMA 6 | 00000000 | 000000 |
| C | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC, 2 A @ 24 V DC | 250V AC 24V DC | 3.6" | 2.1" | 1.3" | 1/2 | __ | NPT | Yes | IP65, NEMA 4 | 00000000 | 000000 |
| C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 3 | 3PST-1NO/2NC | 8 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 250V DC | 3.5" | 2.1" | 1.2" | 1/2 | __ | NPT | Yes | IP67 | 00000000 | 000000 |
| C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 4 A @ 230 V AC, 4 A @ 24 V DC | 500V AC 24V DC | 3.5" | 2" | 1.2" | __ | M16 | Metric | Yes | IP67 | 00000000 | 000000 |
| D | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 6 A @ 120 V AC, 0.27 A @ 24 V DC | 240V AC 250V DC | 3.8" | 1.2" | 1.2" | 1/2 | __ | NPT | Yes | IP67 | 00000000 | 00000 |
| E | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 8 A @ 230 V AC, 5 A @ 24 V DC | 400V AC 24V DC | 4.2" | 2" | 1.6" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
| E | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 8 A @ 230 V AC, 5 A @ 24 V DC | 400V AC 24V DC | 4.2" | 2" | 1.6" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
| F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | __ | M20 | Metric | No | IP67 | 000000000 | 000000 |
| F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | BSPP | No | IP67 | 000000000 | 000000 |
| F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | NPT | No | IP67 | 000000000 | 000000 |
| F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | __ | M20 | Metric | No | IP67 | 000000000 | 00000 |
| F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | BSPP | No | IP67 | 000000000 | 00000 |
| F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | NPT | No | IP67 | 000000000 | 000000 |
Screw Terminal Connection with Positive-Force Normally Closed Contacts and Rotating Head | |||||||||||||||||
| C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 5 A @ 24 V DC | 400V AC 400V DC | 3.5" | 2" | 1.3" | 1/2 | __ | NPT | Yes | IP65 | 00000000 | 000000 |
| D | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 10 A @ 120 V AC, 2.5 A @ 125 V DC | 240V AC 250V DC | 3.8" | 1.2" | 1.2" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
| G | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 10 A @ 230 V AC, 4 A @ 24 V DC | 250V AC 24V DC | 4.3" | 1.6" | 1.4" | __ | M20 | Metric | No | IP67 | 00000000 | 000000 |
Screw Terminal Connection with Rotating Head | |||||||||||||||||
| H | 4 | 2 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 8 | 4PST-2NO/2NC | 2.5 A @ 120 V AC, 1 A @ 125 V DC | 120V AC 125V DC | 7.1" | 1.5" | 1.5" | 1/2 | __ | NPT | No | IP67 | 00000000 | 000000 |
Screw Terminal Connection with Rear Release Button, Portable Key, and LED Status Indicator | |||||||||||||||||
| J | 6 | 2 Off (Normally Open) and 4 On (Normally Closed) | Stays Switched (Maintained) | 12 | 6PST-2NO/4NC | 3 A @ 240 V AC, 2.5 A @ 250 V DC | 240V AC 250V DC | 5.2" | 4.6" | 2.2" | __ | M20 | Metric | Yes | IP67 | 000000000 | 000000 |



O'all | |||||||
|---|---|---|---|---|---|---|---|
| Angle Range | Adjustability | Lg. | Wd. | Mounting Fasteners Included | Each | ||
Straight Keys | |||||||
| For Style E | __ | __ | 80 mm | 32 mm | No | 00000000 | 000000 |
| For Style F | __ | __ | 53.7 mm | 52.4 mm | No | 000000000 | 00000 |
| For Style G | __ | __ | 86 mm | 32 mm | No | 00000000 | 00000 |
| For Style H | __ | __ | 48.5 mm | 35 mm | No | 00000000 | 00000 |
| For Style J | __ | __ | 61.5 mm | 40 mm | No | 000000000 | 00000 |
90° Angle Keys | |||||||
| For Style E | __ | __ | 65.5 mm | 32 mm | No | 00000000 | 00000 |
| For Style J | __ | __ | 45 mm | 40 mm | No | 000000000 | 00000 |
Flexible Keys | |||||||
| For Style D | 0°-15° | Up/Down/Left/Right | 48.9 mm | 55 mm | No | 000000000 | 00000 |
| For Style F | 0°-18° | Left/Right | 80.7 mm | 40 mm | No | 000000000 | 00000 |
| For Style G | 0°-15° | Up/Down/Left/Right | 105 mm | 40 mm | No | 00000000 | 000000 |
| For Style H | 0°-15° | Up/Down/Left/Right | 50.4 mm | 55 mm | No | 00000000 | 00000 |
| For Style J | 0°-18° | Left/Right | 70 mm | 40 mm | No | 000000000 | 00000 |
Hinge-Actuated Safety Switches


Replace the hinges on access doors or machine guards with these switches to keep your team safe from active machinery. Also known as interlock switches, they automatically shut off power to your machinery when the door or guard opens. They can be mounted on flat frames or aluminum T-slotted framing. These switches have positive-force, normally-closed contacts that will open a circuit when the switch is actuated, even if a spring fails or the contacts stick. They’re rated IP65 for protection from washdowns.
Overall | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For Rail Ht., mm | Mounting Hole Ctr.-to-Ctr. Wd., mm | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Wire Connection Type | Conduit Thread Size | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled—2 On (Normally Closed) | ||||||||||||
4° Actuation Angle—Aluminum Hinge | ||||||||||||
| 40 | 44 | Springs Back (Momentary) | 4 | DPST-NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 0000000 |
3 Circuits Controlled—1 Off (Normally Open) and 2 On (Normally Closed) | ||||||||||||
4° Actuation Angle—Aluminum Hinge | ||||||||||||
| 30 | 34 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 5.2" | 4.39" | 1.42" | 00000000 | 000000 |
| 35 | 39 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 5.2" | 4.39" | 1.42" | 00000000 | 000000 |
| 40 | 44 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 0000000 | 000000 |
| 45 | 49 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 5.2" | 4.39" | 1.42" | 00000000 | 000000 |
4° Actuation Angle—Stainless Steel Hinge | ||||||||||||
| 40 | 44 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
8° Actuation Angle—Aluminum Hinge | ||||||||||||
| 40 | 44 | Springs Back (Momentary) | 6 | 3PST-1NO/2NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
3 Circuits Controlled—3 On (Normally Closed) | ||||||||||||
4° Actuation Angle—Aluminum Hinge | ||||||||||||
| 30 | 34 | Springs Back (Momentary) | 6 | 3PST-NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
| 40 | 44 | Springs Back (Momentary) | 6 | 3PST-NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
4° Actuation Angle—Stainless Steel Hinge | ||||||||||||
| 40 | 44 | Springs Back (Momentary) | 6 | 3PST-NC | 2 A @ 230 V AC | Screw Terminals | M20 | 3.62" | 4.39" | 1.42" | 00000000 | 000000 |
Access-Delay Frame-Mounted Safety Switches




Delay access to hazardous areas until conditions are safe; use these switches with machines that take time to stop after they are turned off. Mount the switch to the door frame and mount the key to the door so that the key is inserted into the switch when the door is closed. When the door is pulled, the key is held in place with 225 lbs. of force until the switch receives a signal from a time-delay relay, motion sensor, or position sensor (not included) that the machine’s motion has stopped. After the motion has stopped, the key can be removed from the switch, releasing the access door. They’re often used with machine guards. All have positive-force, normally-closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick. They’re rated for protection from washdowns and temporary submersion.
Style A and B have a key entry on the top and side of the switch.
Style C has a key entry on two opposite sides of the switch.
Emergency override keys (sold separately) bypass the access delay feature.
Housing | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Input Voltage | Holding Force, lbs. | Ht. | Wd. | Dp. | Wire Connection Type | Conduit Trade Size | Each | |
Positive-Force Normally Closed Contacts | ||||||||||||||||
| A | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 24V AC, 24V DC | 225 | 4.7" | 2.3" | 1.4" | Screw Terminals | 1/2 | 0000000 | 0000000 |
| A | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 110V AC | 225 | 4.7" | 2.3" | 1.4" | Screw Terminals | 1/2 | 0000000 | 000000 |
| B | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 14 | 3PST-1NO/2NC | 3 A @ 120 V AC, 2.5 A @ 24 V DC | 250V DC 240V AC | 24V DC | 225 | 3.7" | 3.5" | 1.4" | Screw Terminals | 1/2 | 0000000 | 000000 |
Positive-Force Normally Closed Contacts and Rotating Head | ||||||||||||||||
| C | 4 | 2 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 8 | 4PST-2NO/2NC | 4 A @ 120 V AC, 4 A @ 24 V DC | 240V AC 24V DC | 24V AC, 24V DC | 225 | 7.6" | 1.2" | 1.6" | Screw Terminals | 1/2 | 0000000 | 000000 |
| Emergency Override Key for Style A | 0000000 | Each | 000000 |
RFID Safety Switches

The convenient, modern alternative to mechanical safety switches. These RFID switches are easier to install, fit a wider range of access points, and can mount horizontally. Since they don't need a traditional key to actuate, they work even if the switch and actuator are slightly misaligned. Also known as interlock switches, they shut off power to equipment as soon as you open the barrier, which disconnects the RFID signal. These switches are often used with small machines. Find them anywhere from a CNC machine’s window to a packaging machine’s service panel. Mount the switch on the frame and the actuator on the barrier. Rated IP67 and IP69K, these switches are protected against temporary submersion and high-pressure, high-temperature washdowns.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a magnetic latch help prevent a barrier from opening by accident, such as from light bumps and low vibrations. The magnet keeps the actuator and switch from separating.
Micro M12 cords (sold separately) connect switches to your system’s circuits.

Switches | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | Mounting | Replacement Actuators | ||||||||||||||||
| No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | Ht. | Wd. | Dp. | Fasteners Included | No. of Slots | Slot Lg. | Slot Wd. | Features | Environmental Rating | Each | Each | ||
Plastic Housing | ||||||||||||||||||
With 8-Pole Micro M12 Plug | ||||||||||||||||||
| 1 | __ | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output | IP65, IP67, IP69K | 00000000 | 0000000 | 0000000 | 000000 |
| 1 | 4 | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Magnetic Latch | IP65, IP67, IP69K | 00000000 | 000000 | 0000000 | 00000 |
Cord | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Poles | Coding | Face Dia. | Lg., ft. | Voltage | Current | Wire Gauge | OD | Insulation Material | Environmental Rating | Each | |
| 8 | A | 0.3" | 3 | 30V AC/30V DC | 2A | 22 | 0.22" | PVC Plastic | IP66K, IP67 | 0000000 | 0000000 |
Tamper-Resistant RFID Safety Switches

Block access to machinery while it's running. These safety switches cut power when their signal disconnects, shutting off equipment as you open machine guards. They link to a single actuator, so no other RFID tag or card can interfere. The unique RFID code means that once the power is cut, no one can bypass the switch and restart equipment while the guard is open.
These switches are often used with small machines where there’s no risk of the barrier closing on its own. Find them anywhere from a CNC machine’s window to a machine-operated saw’s service panel. Mount the switch on the frame and the actuator on the barrier. They're also known as interlock switches. Rated IP67 and IP69K, these switches are protected against temporary submersion and high-pressure, high-temperature washdowns.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a magnetic latch prevent guards from opening by accident, such as from light bumps and low vibrations.
Micro M12 cords (sold separately) connect switches to your system’s circuits.

Switches | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | Mounting | Replacement Actuators | ||||||||||||||||
| No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | Ht. | Wd. | Dp. | Fasteners Included | No. of Slots | Slot Lg. | Slot Wd. | Features | Environmental Rating | Each | Each | ||
Plastic Housing | ||||||||||||||||||
With 8-Pole Micro M12 Plug | ||||||||||||||||||
| 1 | __ | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Unique RFID Code | IP65, IP67, IP69K | 00000000 | 0000000 | 0000000 | 000000 |
| 1 | 4 | 12 | 24V DC | 250mA | PNP | 3.6" | 0.9" | 1" | No | 2 | 0.18" | 0.26" | Auxiliary PNP Output, Magnetic Latch, Unique RFID Code | IP65, IP67, IP69K | 00000000 | 000000 | 0000000 | 00000 |
Cord | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Poles | Coding | Face Dia. | Lg., ft. | Voltage | Current | Wire Gauge | OD | Insulation Material | Environmental Rating | Each | |
| 8 | A | 0.3" | 3 | 30V AC/30V DC | 2A | 22 | 0.22" | PVC Plastic | IP66K, IP67 | 0000000 | 0000000 |
Frame-Mounted RFID Safety Switches

Prevent accidental bumps or vibration from triggering these safety switches unnecessarily—a strong magnet maintains the RFID signal between the actuator and switch until it's intentionally opened. Also known as interlock switches, they automatically cut power when you open an access door, interrupting the signal, then restore power when the door is closed, and the switch and actuator meet. They're designed to mount on a frame and a door, gate, or window. Use them in many ways—from turning off a machine-operated saw when you open the protective window to powering down robotic arms when someone enters the partitioned area. The LED indicator shows that your switch is on and whether it’s actuated.
The number of safety outputs, also known as output signal switching devices (OSSDs), tells you how many machines you can control. Each output has a pair of signals that shut down a single machine—if one signal fails, the other takes over as a failsafe.
Switches with a unique RFID code are only compatible with their own actuator, so they’re difficult to tamper with.
IP67 rated switches protect against temporary submersion. IP69K rated switches protect against high-pressure, high-temperature washdowns.


Switches | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | Replacement Actuators | ||||||||||||||||
| No. of Safety Outputs | Holding Force, lbs. | Max. Sensing Distance, mm | Input Voltage | Current Output | Signal Output Type | No. of Wire Leads | Cable Lead Lg. | Ht. | Wd. | Dp. | Mounting Fasteners Included | Features | Environmental Rating | Each | Each | ||
Plastic Housing | |||||||||||||||||
With 8-Pole Micro M12 Plug | |||||||||||||||||
| 1 | 152 | 10 | 24V DC | 200mA | PNP | __ | 10" | 3.8" | 2.5" | 1.5" | Yes | Auxiliary PNP Output, LED Status Indicator, Magnetic Latch | IP67 | 0000000 | 0000000 | 0000000 | 0000000 |
Stainless Steel Housing | |||||||||||||||||
With Wire Leads | |||||||||||||||||
| 1 | 101 | 10 | 24V DC | 200mA | PNP | 8 | 16ft. | 3.8" | 2.5" | 1.5" | Yes | Auxiliary PNP Output, LED Status Indicator, Magnetic Latch, Unique RFID Code | IP69K | 0000000 | 000000 | 000000 | 00 |

| No. of Poles | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Lead Lg., ft. | Housing Material | Environmental Rating | Each | |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 30 | 0.23" | 9.5 | Polyurethane Rubber | IP67, IP66K | 0000000 | 000000 |
Light Beam Safety Barrier Switches

Micro
M12 Plug
Micro
M12 Plug
Micro
M12 Plug
Immediately cut power to machinery by breaking the light beam between two barriers. Light beams can travel up to 32 or 65 feet between the transmitter and receiver. They’re rated IP67, so they can be used in wet areas. For a complete switching system, combine a transmitter and receiver, safety relay, and connectors (all sold separately).
These switches can be configured for complex setups. To selectively allow material to pass through the sensing field, you can program the system to allow one or more beams to be broken without shutting off your machine. To create a perimeter guard that bends around corners, add mirrors to reflect light beams at an angle.
Note: These switches cannot be used with a full-revolution clutch press or machine. Use only with machinery that can consistently and immediately stop anywhere in its cycle.

Finger-safe switches trigger from objects the size of a finger passing through. Those with Bluetooth let you monitor switching status, beam alignment, and other data on your phone.
Swivel brackets can be adjusted during and after installation for easy alignment.
Switches | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Plug Type | Replacement Fixed Brackets | Swivel Brackets | |||||||||||||||||||||
| Light Beam Ht. | Light Beam Switch Operation | Sensing Distance, ft. | Input Voltage | Current Output | Maximum Load Current | Signal Output Type | Transmitter | Receiver | Ht. | Wd. | Dp. | Housing Material | Color | Includes | Cable Lg., ft. | Each | Pkg. Qty. | Pkg. | Pkg. Qty. | Pkg. | |||
0.55" Minimum Object Size Detected | |||||||||||||||||||||||
| 6.3" | On When Object Absent | 1-32 | 24V DC | 115mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 8.2" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 000000000 | 2 | 0000000 | 000000 | 2 | 0000000 | 0000000 |
| 9.4" | On When Object Absent | 1-32 | 24V DC | 120mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 11.3" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 0000000 | 000000 |
| 12.6" | On When Object Absent | 1-32 | 24V DC | 130mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 14.5" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 0000000 | 000000 |
| 15.7" | On When Object Absent | 1-32 | 24V DC | 140mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 17.6" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 0000000 | 000000 |
| 18.9" | On When Object Absent | 1-32 | 24V DC | 130mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 20.8" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 0000000 | 000000 |
| 22" | On When Object Absent | 1-32 | 24V DC | 135mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 23.9" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 0000000 | 000000 |
| 28.3" | On When Object Absent | 1-32 | 24V DC | 150mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 30.2" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 0000000 | 000000 |
| 34.6" | On When Object Absent | 1-32 | 24V DC | 160mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 36.5" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 0000000 | 000000 |
| 47.2" | On When Object Absent | 1-32 | 24V DC | 190mA | 300mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 49.1" | 1.4" | 1.4" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | 1 | 0000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 0000000 | 000000 |
0.55" Minimum Object Size Detected—Bluetooth | |||||||||||||||||||||||
| 9.8" | On When Object Absent | 10-32 | 24V DC | 900mA | __ | PNP | 4-pole Micro M12 | 8-pole Micro M12 | 14.3" | 1.1" | 1.3" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | __ | 00000000 | 00000000 | __ | 000000 | 00 | __ | 000000 | 00 |
| 13" | On When Object Absent | 10-32 | 24V DC | 900mA | __ | PNP | 4-pole Micro M12 | 8-pole Micro M12 | 17.4" | 1.1" | 1.3" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | __ | 00000000 | 00000000 | __ | 000000 | 00 | __ | 000000 | 00 |
| 22.4" | On When Object Absent | 10-32 | 24V DC | 900mA | __ | PNP | 4-pole Micro M12 | 8-pole Micro M12 | 26.9" | 1.1" | 1.3" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | __ | 00000000 | 00000000 | __ | 000000 | 00 | __ | 000000 | 00 |
| 28.7" | On When Object Absent | 10-32 | 24V DC | 900mA | __ | PNP | 4-pole Micro M12 | 8-pole Micro M12 | 33.2" | 1.1" | 1.3" | Painted Aluminum | Yellow | Four Fixed Mounting Brackets | __ | 00000000 | 00000000 | __ | 000000 | 00 | __ | 000000 | 00 |

Hand-safe switches trigger from objects the size of a hand passing through—but not slimmer objects such as a finger. For switches with a light beam height up to 9.4", you’ll need four fixed or two swivel brackets. For switches with a light beam height of 12.6" and greater, you’ll need four fixed or four swivel brackets.
Swivel brackets can be adjusted during and after installation for easy alignment.
Switches | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Plug Type | Fixed Brackets | Swivel Brackets | |||||||||||||||||||
| Light Beam Ht. | Light Beam Switch Operation | Sensing Distance, ft. | Input Voltage | Current Output | Signal Output Type | Transmitter | Receiver | Ht. | Wd. | Dp. | Housing Material | Color | Cable Lg., ft. | Each | Pkg. Qty. | Pkg. | Pkg. Qty. | Pkg. | |||
0.98" Minimum Object Size Detected | |||||||||||||||||||||
| 6.3" | On When Object Absent | 1-65 | 24V DC | 155mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 6.3" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 0000000 | 2 | 0000000 | 000000 | 2 | 00000000 | 0000000 |
| 9.4" | On When Object Absent | 1-65 | 24V DC | 160mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 9.4" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 000000 | 2 | 0000000 | 00000 | 2 | 00000000 | 000000 |
| 12.6" | On When Object Absent | 1-65 | 24V DC | 160mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 12.6" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 000000 | 2 | 0000000 | 00000 | 2 | 00000000 | 000000 |
| 15.7" | On When Object Absent | 1-65 | 24V DC | 160mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 15.7" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 000000 | 2 | 0000000 | 00000 | 2 | 00000000 | 000000 |
| 18.9" | On When Object Absent | 1-65 | 24V DC | 165mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 18.9" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 00000000 | 000000 |
| 22" | On When Object Absent | 1-65 | 24V DC | 165mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 22" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 00000000 | 000000 |
| 28.3" | On When Object Absent | 1-65 | 24V DC | 175mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 28.3" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 00000000 | 000000 |
| 34.6" | On When Object Absent | 1-65 | 24V DC | 180mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 34.6" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 00000000 | 000000 |
| 47.2" | On When Object Absent | 1-65 | 24V DC | 190mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 47.2" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 00000000 | 00000000 | 2 | 0000000 | 00000 | 2 | 00000000 | 000000 |

Safety relays send a signal to shut off your machinery when the light beams are breached and restart when the issue is resolved. IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. Mount them to 35 mm DIN rail (also known as DIN 3 Rail) for fast installation. These relays meet ISO and IEC standards for machine safety and can help achieve PL, SIL, or CAT system ratings.
| Number of Terminals | Input Voltage | Switching Current @ Voltage | Maximum Switching Voltage | Wire Connection Type | Ht. | Wd. | Dp. | For Use With | Maximum System Safety Rating | Features | Each | |
2 Circuits Controlled with 2 Off (Normally Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 14 | 24V DC | 2 A @ 240 V AC, 1.5 A @ 24 V DC | 250V AC | Terminal Block | 4.9" | 0.69" | 4.3" | Emergency Stops, Light Curtains | PLe, SIL3, CAT 4, 250V | Auxiliary PNP Output, LED Indicator | 0000000 | 0000000 |
4 Circuits Controlled with 4 Off (Normally Open) | ||||||||||||
| 18 | 24V DC | 2 A @ 240 V AC, 1.5 A @ 24 V DC | 250V AC | Terminal Block | 4.9" | 0.89" | 4.3" | Emergency Stops, Light Curtains | PLe, SIL3, CAT 4, 250V | Auxiliary PNP Output, LED Indicator | 0000000 | 000000 |
Micro
M12 Socket
| No. of Poles | Gender | Wire Connection Type | Cable Lead Lg., ft. | Each | |
| 8 | Female | Wire Leads | 32 1/2 | 0000000 | 0000000 |
Micro
M12 Socket
Micro
M12 Plug
| No. of Poles | Gender | Cable Lead Lg., ft. | Each | |
| 8 | Female × Male | 9 1/2 | 0000000 | 000000 |

Micro
M12 Socket
Micro
M12 Socket
Transmitter and receiver connecting cords link multiple safety barrier switches in a row. They include one cord to connect two transmitters, and one cord to connect two receivers.
| No. of Poles | Gender | No. of Cords | Cable Lead Lg. | Each | |
| 5, 8 | Female | 2 | 8" | 0000000 | 0000000 |
Light Beam Safety Barrier Switches for Long Distances

Spanning up to 230 ft.—roughly the length of a commercial airplane—these safety barrier switches cut power to large machinery to prevent damage or injury. They trigger the instant a person or object crosses the light beams between the transmitter and receiver. To selectively allow material to pass through the sensing field, you can program the system to allow one or more beams to be broken without shutting off your machine. To create a perimeter guard that bends around corners, add mirrors to reflect light beams at an angle. Rated IP67, these switches withstand wet conditions.
For a complete switching system, combine a transmitter and receiver, safety relay, and connectors (all sold separately).
Note: These switches cannot be used with a full-revolution clutch press or machine. Use only with machinery that can consistently and immediately stop anywhere in its cycle.
Safety relays send a signal to shut off your machinery when the light beams are breached and restart when the issue is resolved. IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. Mount them to 35 mm DIN rail (also known as DIN 3 Rail) for fast installation. These relays meet ISO and IEC standards for machine safety and can help achieve PL, SIL, or CAT system ratings.
Transmitter and receiver connecting cords link multiple safety barrier switches in a row. They include one cord to connect two transmitters, and one cord to connect two receivers.
All switches require four fixed or four swivel brackets. Swivel brackets can be adjusted during and after installation for easy alignment. Swivel brackets also allow you to use floor stands, which shield transmitters and receivers from impact.

Plug Type | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Light Beam Ht. | Light Beam Switch Operation | Sensing Distance, ft. | Input Voltage | Current Output | Signal Output Type | Transmitter | Receiver | Ht. | Wd. | Dp. | Housing Material | Color | Cable Lg., ft. | Each | |
Body Safe | |||||||||||||||
11.8" Minimum Object Size Detected | |||||||||||||||
| 35.4" | On When Object Absent | 1-230 | 24V DC | 140mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 42.1" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 0000000 | 000000000 |
15.7" Minimum Object Size Detected | |||||||||||||||
| 31.5" | On When Object Absent | 1-230 | 24V DC | 130mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 38.2" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 0000000 | 00000000 |
| 47.2" | On When Object Absent | 1-230 | 24V DC | 140mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 53.9" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 0000000 | 00000000 |
19.7" Minimum Object Size Detected | |||||||||||||||
| 19.7" | On When Object Absent | 1-230 | 24V DC | 120mA | PNP/NPN | 5-pole Micro M12 | 8-pole Micro M12 | 26.4" | 1.3" | 1.5" | Painted Aluminum | Yellow | 1 | 0000000 | 00000000 |

| Number of Terminals | Input Voltage | Switching Current @ Voltage | Maximum Switching Voltage | Wire Connection Type | Ht. | Wd. | Dp. | For Use With | Maximum System Safety Rating | Features | Each | |
2 Circuits Controlled with 2 Off (Normally Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 14 | 24V DC | 2 A @ 240 V AC, 1.5 A @ 24 V DC | 250V AC | Terminal Block | 4.9" | 0.69" | 4.3" | Emergency Stops, Light Curtains | PLe, SIL3, CAT 4, 250V | Auxiliary PNP Output, LED Indicator | 0000000 | 0000000 |
4 Circuits Controlled with 4 Off (Normally Open) | ||||||||||||
| 18 | 24V DC | 2 A @ 240 V AC, 1.5 A @ 24 V DC | 250V AC | Terminal Block | 4.9" | 0.89" | 4.3" | Emergency Stops, Light Curtains | PLe, SIL3, CAT 4, 250V | Auxiliary PNP Output, LED Indicator | 0000000 | 000000 |
Micro
M12 Female
| No. of Poles | Gender | Wire Connection Type | Cable Lead Lg., ft. | Each | |
| 5 | Female | Wire Leads | 32 1/2 | 0000000 | 000000 |
Micro
M12 Female
| No. of Poles | Gender | Wire Connection Type | Cable Lead Lg., ft. | Each | |
| 8 | Female | Wire Leads | 32 1/2 | 0000000 | 0000000 |
Micro
M12 Female
Micro
M12 Male
| No. of Poles | Gender | Cable Lead Lg., ft. | Each | |
| 8 | Female × Male | 9 1/2 | 0000000 | 000000 |

Micro
M12 Female
Micro
M12 Female
| No. of Poles | Gender | No. of Cords | Cable Lead Lg. | Each | |
| 5, 8 | Female | 2 | 8" | 0000000 | 0000000 |
Harsh Environment Light Beam Safety Barrier Switches
Shut off machinery on your roughest, dirtiest job sites the second someone or something gets too close. Shielded by a polycarbonate housing, these safety barrier switches withstand impact better than standard models. Rated IP69, they’re sealed to keep out dust and high-pressure, high-temperature washdowns, so they'll stand up to mud, water, and heat on site. They're often used in construction zones and mining operations. When conditions are too harsh for inspections, use Bluetooth to send diagnostics to your phone. Simply connect to the app to monitor switching status, beam alignment, and other data from afar.
These switches trigger when the light beams between the transmitter and receiver are interrupted. To selectively allow material to pass through the sensing field, you can program the system to allow one or more beams to be broken without shutting off your machine. To create a perimeter guard that bends around corners, add mirrors to reflect light beams at an angle.
For a complete switching system, combine a transmitter and receiver, which are sold together, with a safety relay (sold separately).
Note: These switches cannot be used with a full-revolution clutch press or machine. Use only with machinery that can consistently and immediately stop anywhere in its cycle.
Finger-safe switches trigger from objects the size of a finger passing through. Hand-safe switches trigger from objects the size of a hand passing through.
Safety relays send a signal to shut off your machinery when the light beams are breached and restart when the issue is resolved. IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. Mount them to 35 mm DIN rail (also known as DIN 3 Rail) for fast installation. These relays meet ISO and IEC standards for machine safety and can help achieve PL, SIL, or CAT system ratings.



Micro
M12 Plug
Micro
M12 Plug
Plug Type | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Light Beam Ht. | Light Beam Switch Operation | Sensing Distance, ft. | Input Voltage | Current Output | Signal Output Type | Transmitter | Receiver | Ht. | Wd. | Dp. | Housing Material | Color | Includes | Cable Lg., ft. | Each | |
Finger Safe (0.55" Minimum Object Size Detected) | ||||||||||||||||
| 13" | On When Object Absent | 1-23 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 18.1" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 000000000 |
| 19.3" | On When Object Absent | 1-23 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 24.4" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 25.6" | On When Object Absent | 1-23 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 30.7" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 28.7" | On When Object Absent | 1-23 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 33.9" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 35" | On When Object Absent | 1-23 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 40.2" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 38.2" | On When Object Absent | 1-23 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 43.3" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 47.6" | On When Object Absent | 1-23 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 52.8" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 53.9" | On When Object Absent | 1-23 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 59.1" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
Hand Safe (1.18" Minimum Object Size Detected) | ||||||||||||||||
| 13" | On When Object Absent | 1-32 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 18.1" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 19.3" | On When Object Absent | 1-32 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 24.4" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 25.6" | On When Object Absent | 1-32 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 30.7" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 28.7" | On When Object Absent | 1-32 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 33.9" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 35" | On When Object Absent | 1-32 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 40.2" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 38.2" | On When Object Absent | 1-32 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 43.3" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 47.6" | On When Object Absent | 1-32 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 52.8" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |
| 53.9" | On When Object Absent | 1-32 | 24V DC | 700mA | PNP | 4-pole Micro M12 | 5-pole Micro M12 | 59.1" | 2.4" | 2.4" | Polycarbonate Plastic | Yellow | Four Fixed Mounting Brackets | 33 | 0000000 | 00000000 |

| Number of Terminals | Input Voltage | Switching Current @ Voltage | Maximum Switching Voltage | Wire Connection Type | Ht. | Wd. | Dp. | For Use With | Maximum System Safety Rating | Features | Each | |
2 Circuits Controlled with 2 Off (Normally Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 14 | 24V DC | 2 A @ 240 V AC, 1.5 A @ 24 V DC | 250V AC | Terminal Block | 4.9" | 0.69" | 4.3" | Emergency Stops, Light Curtains | PLe, SIL3, CAT 4, 250V | Auxiliary PNP Output, LED Indicator | 0000000 | 0000000 |
4 Circuits Controlled with 4 Off (Normally Open) | ||||||||||||
| 18 | 24V DC | 2 A @ 240 V AC, 1.5 A @ 24 V DC | 250V AC | Terminal Block | 4.9" | 0.89" | 4.3" | Emergency Stops, Light Curtains | PLe, SIL3, CAT 4, 250V | Auxiliary PNP Output, LED Indicator | 0000000 | 000000 |
Safety Laser Scanners
Monitor a wide area around dangerous machinery. If a person or object gets too close, these scanners signal your relay or controller to either trigger a warning or shut down the machinery. For example, they can slow a robotic arm if someone comes within 20 ft., then stop it completely if they come within 10 ft. You can also set these scanners to respond only when they detect objects of a certain size. Since they continuously monitor 275°, they cover a much wider area than light beam safety barrier switches.
These scanners have a dedicated safety output for triggering emergency stops, and three inputs/outputs that you can configure. The safety output sends two duplicate signals at the same time—also called redundant signals—so even if one fails, the other will stop your equipment. Wire this output to safety relays or safety terminals on a controller. The inputs/outputs can be configured to set off warnings or adjust the scanner’s behavior. When used as outputs, they can send a signal to flash a light, sound an alarm, or slow a machine. When used as inputs, they can signal the scanner to ignore robot arms or other expected objects, while still scanning for people and unexpected objects.
Download free software onto a computer running Windows to set the monitoring distance, the size of the objects you want to detect, and the function of the inputs/outputs. You can also save up to six different configurations on the scanner itself.
Rated IP65, these switches are sealed to keep out dust and low-pressure jets of water. They’re UL and C-UL listed, CE marked, and TUV SUD certified, so they meet U.S. and international safety standards. They also meet EN, ISO, and IEC standards for performance and safety.
You’ll need a power/input/output cable to connect the scanner to your power supply, controller, or relay. Use an ethernet cord to connect the scanner to your computer for programming.
Mount these scanners to a flat surface using holes on the back. Add a mounting bracket to tilt the scanner toward the area you want to monitor. To shield the top of your scanner from falling objects and collisions, mount a protective bracket onto the mounting bracket.


| Safety Sensing Distance Range | No. of Safety Outputs | Configurable Input/Output Sensing Distance Range | No. of Configurable Inputs/Outputs | Min. Object Size Detected | Signal Input/Output Type | Input Voltage | Max. Sensing Angle | Wd. | Ht. | Dp. | Housing Material | Housing Color | Each | |
8-Pole M12 Socket Connection | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2"-9.8 ft. | 1 | 2"-131.2 ft. | 3 | 1.2" | PNP | 24V DC | 275° | 4" | 6" | 4.4" | Powder-Coated Aluminum | Yellow | 0000000 | 000000000 |
| 2"-18 ft. | 1 | 2"-131.2 ft. | 3 | 1.2" | PNP | 24V DC | 275° | 4" | 6" | 4.4" | Powder-Coated Aluminum | Yellow | 0000000 | 00000000 |
| Number of Poles | Transmission Speed, Mbps | Wire Gauge | Cord OD | Shielding | Shield Type | Temp. Range, °F | Cord Insulation Material | Color | Each | |
9 1/2 ft. Lg. | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
D-Coded—Ethernet Cable Category 5E | ||||||||||
| 4 | 100 | 24 | 0.26" | Double Shielded | Braid, Foil | -40° to 175° | TPE Rubber | Blue | 00000000 | 000000 |
32 1/2 ft. Lg. | ||||||||||
D-Coded—Ethernet Cable Category 5E | ||||||||||
| 4 | 100 | 24 | 0.26" | Double Shielded | Braid, Foil | -40° to 175° | TPE Rubber | Blue | 00000000 | 000000 |

| Material | Mounting Fasteners Included | Each | |
| Zinc-Plated Steel | Yes | 0000000 | 000000 |





























