About Wire and Cable
More
About Conduit
More
Hazardous Location Conduit Access Ports
Also known as conduit bodies, these ports provide access to wire and cable inside thick-wall (rigid) metal conduit for pulling, splicing, and maintenance. They are also used to change the direction of a run. These ports meet Class I, II, and III; Divisions 1 and 2 standards for flammable gases, combustible dust, and combustible fibers in hazardous locations.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Material | Features | Environmental Rating | Each | |
Straight (C) | ||||||||
1/2 | 1/2 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 0000000 |
3/4 | 3/4 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 000000 |
1 | 1 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 000000 |
Tee (T) | ||||||||
1/2 | 1/2 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 000000 |
3/4 | 3/4 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 000000 |
1 | 1 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 000000 |
90° Elbow (LB) | ||||||||
1/2 | 1/2 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 000000 |
3/4 | 3/4 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 000000 |
1 | 1 | NPT | Female | Aluminum | Removable Cover | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | 0000000 | 000000 |
Hazardous Location Conduit Connectors
Use to join pieces of thick-wall (rigid) metal conduit. These connectors meet Classes I, II, and III, Divisions 1 and 2 standards for flammable gases, combustible dust, and combustible fibers in hazardous locations. The sealant chamber requires packing fiber and sealing compound (sold separately). They minimize the travel of gases and flames through conduit.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Material | For Conduit Material | Environmental Rating | Specifications Met | Each | |
Straight Connectors with Sealant Chamber | |||||||||
1/2 | 1/2 | NPT | Female | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 000000 |
3/4 | 3/4 | NPT | Female | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
1 | 1 | NPT | Female | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
1 1/4 | 1 1/4 | NPT | Female | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
1 1/2 | 1 1/2 | NPT | Female | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
2 | 2 | NPT | Female | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 000000 |
Hazardous Location Conduit Bushings
Join two different sizes of thick-wall (rigid) metal conduit. These bushings meet Class I and II, Division 1 and 2 standards for flammable gases and combustible dust in hazardous locations.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Material | Environmental Rating | Specifications Met | Each | |
3/4 × 1/2 | 3/4 × 1/2 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
1 × 1/2 | 1 × 1/2 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 0000 |
1 × 3/4 | 1 × 3/4 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 0000 |
1 1/4 × 1/2 | 1 1/4 × 1/2 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 0000 |
1 1/4 × 3/4 | 1 1/4 × 3/4 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 0000 |
1 1/4 × 1 | 1 1/4 × 1 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 0000 |
1 1/2 × 1 | 1 1/2 × 1 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
2 × 1 | 2 × 1 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
2 × 1 1/2 | 2 × 1 1/2 | NPT | Male × Female | Aluminum | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
Hazardous Location Conduit Adapters
Use to connect thick-wall (rigid) metal conduit to a knockout in an outlet box or enclosure.
Adapters with sealant chamber require packing fiber and sealing compound (sold separately). They minimize the travel of gases and flames through conduit.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | Conduit or Electrical Box Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Conduit Trade Size | Pipe Size | Thread Type | Gender | Material | For Conduit Material | Environmental Rating | Specifications Met | Each | |
Straight Adapters with Sealant Chamber | |||||||||||||
1/2 | 1/2 | NPT | Female | 1/2 | 1/2 | NPT | Male | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 000000 |
3/4 | 3/4 | NPT | Female | 3/4 | 3/4 | NPT | Male | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
1 | 1 | NPT | Female | 1 | 1 | NPT | Male | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
1 1/4 | 1 1/4 | NPT | Female | 1 1/4 | 1 1/4 | NPT | Male | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | UL Listed; CSA Certified | 0000000 | 00000 |
1 1/2 | 1 1/2 | NPT | Female | 1 1/2 | 1 1/2 | NPT | Male | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | UL Listed; CSA Certified | 0000000 | 000000 |
2 | 2 | NPT | Female | 2 | 2 | NPT | Male | Aluminum | Aluminum, Stainless Steel, Steel | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | UL Listed; CSA Certified | 0000000 | 000000 |
Armored Building Cable
- Use For: Buildings
- Flexible
- Temperature Range:
MC, THHN: 15° to 190° F
MC, XHHW-2: -40° to 190° F - Outer Insulation:
MC, THHN: Aluminum Armor
MC, XHHW-2: Aluminum Armor, PVC Plastic - Inner Insulation:
MC, THHN: PVC Plastic
MC, XHHW-2: Cross-Linked Polyethylene (XLPE)
Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Cable with THHN wire stands up to condensation and moisture in basements and other damp environments.
Cable with XHHW-2 wire has a PVC outer jacket over the aluminum armor. You can use it in wet environments where liquid might drip and splash on it. It can also be used for direct burial without a conduit.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Features | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
MC, THHN Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.44" | Black, Green, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
14 | 4 | 14/4 | 15 A @ 86° F | 0.49" | Black, Blue, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
12 | 2 | 12/2 | 20 A @ 86° F | 0.48" | Black, Green, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.51" | Black, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
12 | 4 | 12/4 | 20 A @ 86° F | 0.54" | Black, Blue, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
10 | 2 | 10/2 | 30 A @ 86° F | 0.54" | Black, Green, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
10 | 3 | 10/3 | 30 A @ 86° F | 0.58" | Black, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
10 | 4 | 10/4 | 30 A @ 86° F | 0.62" | Black, Blue, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
MC, XHHW-2 Stranded Wire | ||||||||||||||
600V AC/600V DC | ||||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.64" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.65" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
12 | 4 | 12/4 | 20 A @ 86° F | 0.68" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
10 | 3 | 10/3 | 30 A @ 86° F | 0.7" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
10 | 4 | 10/4 | 30 A @ 86° F | 0.74" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 |
Armored Fire Alarm Cable
- Use For: Buildings
- Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: Aluminum Armor
Inner: Nylon Plastic, PVC Plastic
Prevent damage to wires for fire alarm systems, smoke detectors, and other critical circuits with this armored cable. Also known as metal clad (MC) cable, the metal armor acts as a conduit to protect the wires inside. The PVC inner insulation resists flames. Its nylon jacket is low smoke, so it can be used without conduit in duct work, under raised floors, and above a drop ceiling. This cable has a ground wire that is not counted in the number of wires.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it’s rated for your environment.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Solid Wire | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | |||||||||||||||
18 | 4 | 18/4 | 0.43" | Red | Black, Blue, Green, Red, White | Insulated Ground Wire | MC-FPLP | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL Listed, UL 2556 VW-1 | 0000000 | |||||
Shielded Solid Wire | |||||||||||||||
300V AC/300V DC | |||||||||||||||
18 | 2 | 18/2 | 0.39" | Red | Black, White | Uninsulated Ground Wire | MC-FPLP | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL Listed, UL 2556 VW-1 | 0000000 |