About Hazardous Location Environmental Ratings
More
About Selecting Temperature Sensors
More
Adjustable-Power Temperature Controllers for Plug-In Heaters

Regulate the amount of power flowing to your heater with the turn of a dial. Instead of a temperature sensor or input, these controllers work like a dimmer on a light switch. To incorporate them, first plug in the temperature controller, then plug your heater into the socket on the bottom of the controller. These controllers are NEMA rated for use in hazardous, corrosive, dusty, and washdown environments.
Plug | Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Output Voltage Range | Current, A | Input Voltage | Type | NEMA Style | End Shape | NEMA Style | End Shape | Cord Lg., ft. | Ht. | Wd. | Dp. | Environmental Rating | Each | |
36V AC to 120V AC | 10 | 120V AC | Three Prong | 5-15 | Straight | 5-15 | Straight | 6 | 4 5/8" | 2 11/16" | 2" | NEMA 4X, NEMA 7 | 000000 | 000000 |
Hazardous Location Threaded Temperature Switches

Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
Switch with one actuation point has one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Switch with two actuation points has two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Probe | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | No. of Actuation Points | Actuation Tolerance | No. of Circuits Controlled | Electrical Phase | Max. Switching Current @ Voltage | Dia. | Lg. | Material | Ht. | Wd. | Dp. | Environmental Rating | Each | |
Threaded Brass Probe—1/2 NPT Male | ||||||||||||||
0° to 225° | 1 | ±1% | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | Brass | 10" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 0000000 | 0000000 |
0° to 225° | 2 | ±1% | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | Brass | 10" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 0000000 | 00000000 |
Hazardous Location Wall-Mount Temperature Switches


Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
Switch with one actuation point has one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
Switch with two actuation points has two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Temp. Accuracy, °F | No. of Actuation Points | Electrical Phase | Max. Switching Current | Dia. | Lg. | Ht. | Wd. | Dp. | Environmental Rating | Includes | Each | |
SPDT—1 Circuit Controlled | |||||||||||||
Threaded Stainless Steel Probe—1/2 NPT Male | |||||||||||||
30° to 250° | ±5° | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 1/2 × 3/4 NPT Adapter Bushing | 0000000 | 000000000 |
SPDT—2 Circuit Controlled | |||||||||||||
Unthreaded Stainless Steel Probe | |||||||||||||
30° to 250° | ±5° | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | __ | 0000000 | 00000000 |
Packing Seals and Fittings | 0000000 | Each | 000000 |
Hazardous Location Threaded Thermocouple Probes for Liquids and Gases


Safe to use while measuring temperatures near flammable gases or combustible dust, these probes have an explosionproof head that’s FM approved. They are stainless steel to resist corroding when immersed in liquids and gases. They can also be used with solids, such as molds and dies, because the stainless steel acts as a shield if they’re hit or bumped. Rated NEMA 4, these probes seal out dust and water from washdowns. A layer of magnesium oxide protects the wiring inside. To adjust the length of the probe for your application, slide the fitting up towards the probe head or down towards the tip. Once it’s in the right spot, tighten the fitting to compress it against the probe, securing it in place.
Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. These probes are often used with temperature controllers, thermometers, and other temperature-reading devices. Remove the cap on the head to wire them to your device.
These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
Probe | Probe Connection | Conduit Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Max. Temp., °F | Accuracy | Overall Lg. | Sensor Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Environmental Rating | Each | |
446 Stainless Steel Probe | |||||||||||||||
Type J | |||||||||||||||
1"-3" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 10 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 0000000 |
4"-6" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 13 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
8"-10" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 17 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
10"-12" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 19 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
14"-16" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 23 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
20"-22" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 29 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
Type K | |||||||||||||||
1"-3" | 1/2" | 2100° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 10 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
4"-6" | 1/2" | 2100° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 13 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
8"-10" | 1/2" | 2100° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 17 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
10"-12" | 1/2" | 2100° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 19 7/8" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
14"-16" | 1/2" | 2100° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 23 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
20"-22" | 1/2" | 2100° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 29 1/4" | Grounded | 1/2 | NPT | Male | 3/4 | NPT | Female | FM Approved | NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEMA 4 | 0000000 | 000000 |
Hazardous Location Threaded Thermocouple
Probes with Thermowell for Liquids and Gases


With an FM-approved explosionproof head, these probes are safe to use around flammable gases, vapors, and dust. The included stainless steel thermowell shields them against corrosion, shock, vibration, and impact as they measure the temperature of liquids and gases. By creating a barrier, the thermowell also lets you replace the probe sensor without stopping flow or draining your system. Rated NEMA 4, these probes seal out dust and water from washdowns. To protect the wiring inside, these probes have ceramic insulation. The NPT fitting that threads into the thermowell is welded on, so you can’t adjust the probe’s length.
Pick the thermocouple type that best covers the temperature range you expect your liquid or gas to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They’re often used with temperature controllers, thermometers, and other temperature-reading devices. Remove the cap on the head to wire them to your device.
These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
Probe | Thermowell Connection | Conduit Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Max. Temp., °F | Accuracy | Overall Lg. | Sensor Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Connection Type | Environmental Rating | Each | |
316 Stainless Steel Thermowell | |||||||||||||||
Type J | |||||||||||||||
4 1/2" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 13 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 0000000 |
7 1/2" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 16 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 000000 |
10 1/2" | 1/2" | 1400° | ±4° F between 32° to 533° F ±0.75% above 533° F | 19 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 000000 |
Type K | |||||||||||||||
4 1/2" | 1/2" | 1650° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 13 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 000000 |
7 1/2" | 1/2" | 1650° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 16 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 000000 |
10 1/2" | 1/2" | 1650° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 19 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 000000 |
Type T | |||||||||||||||
4 1/2" | 1/2" | 660° | Not Rated below 32° F ±1.8° F between 32° to 240° F ±0.75% above 240° F | 13 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 000000 |
7 1/2" | 1/2" | 660° | Not Rated below 32° F ±1.8° F between 32° to 240° F ±0.75% above 240° F | 16 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 000000 |
10 1/2" | 1/2" | 660° | Not Rated below 32° F ±1.8° F between 32° to 240° F ±0.75% above 240° F | 19 1/8" | Grounded | 3/4 | NPT | Male | 3/4 | NPT | Female | Screw Terminal | NEC Class I Divisions 1, 2 Groups A, B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEMA 4 | 00000000 | 000000 |
Hazardous Location Threaded Thermocouple
Probe Transmitters for Liquids and Gases


Safely measure the temperature of liquids and gases in places where flammable gases, vapors, dust, and fibers are present. The head of these transmitters is FM approved and CSA certified for use in hazardous areas. It’s also NEMA 4X and IP68 rated, so it stands up to wet and dusty environments and even brief submersion. These transmitters convert readings to analog signals and send them to devices such as remote displays and programmable logic controllers (PLCs).
To measure liquids, you’ll need to connect a thermowell or protective tube before immersing the probe in a tank or pipe. Otherwise, liquid will be sucked into the head through the fitting, which will damage the wiring. The probe can also be used to measure solids, such as molds and dies—it's made of stainless steel or nickel to shield against impacts. It also has a layer of magnesium oxide to protect the wiring inside the probe. For accurate readings, a spring inside the fitting pushes the probe tip forward, keeping it in constant contact with the surface you're measuring. The head has a removable cap for easy access to sensor connections.
These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
For technical drawings and 3-D models, click on a part number.
Probe | Probe Connection | Conduit Connection | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Response Time, sec. | Temp. Range, °F | Accuracy | Overall Lg. | Sensor Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Output Current Range | Voltage Range | Environmental Rating | Each | |
Type J | |||||||||||||||||
316 Stainless Steel Probe | |||||||||||||||||
2 1/2" | 1/4" | 5 | 0° to 500° | Not Rated below 32° F ±4° F between 32° to 500° F | 8 1/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 0000000 |
4" | 1/4" | 5 | 0° to 500° | Not Rated below 32° F ±4° F between 32° to 500° F | 9 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
6" | 1/4" | 5 | 0° to 500° | Not Rated below 32° F ±4° F between 32° to 500° F | 11 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
9" | 1/4" | 5 | 0° to 500° | Not Rated below 32° F ±4° F between 32° to 500° F | 14 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
12" | 1/4" | 5 | 0° to 500° | Not Rated below 32° F ±4° F between 32° to 500° F | 17 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
Type K | |||||||||||||||||
Nickel Probe | |||||||||||||||||
2 1/2" | 1/4" | 5 | 0° to 2150° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 8 1/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
4" | 1/4" | 5 | 0° to 2150° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 9 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
6" | 1/4" | 5 | 0° to 2150° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 11 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
9" | 1/4" | 5 | 0° to 2150° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 14 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
316 Stainless Steel Probe | |||||||||||||||||
12" | 1/4" | 5 | 0° to 2150° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | 17 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
Type T | |||||||||||||||||
316 Stainless Steel Probe | |||||||||||||||||
2 1/2" | 1/4" | 5 | -328° to 100° | Not Rated below 32° F ±1.8° F between 32° to 100° F | 8 1/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
4" | 1/4" | 5 | -328° to 100° | Not Rated below 32° F ±1.8° F between 32° to 100° F | 9 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
6" | 1/4" | 5 | -328° to 100° | Not Rated below 32° F ±1.8° F between 32° to 100° F | 11 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
9" | 1/4" | 5 | -328° to 100° | Not Rated below 32° F ±1.8° F between 32° to 100° F | 14 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
12" | 1/4" | 5 | -328° to 100° | Not Rated below 32° F ±1.8° F between 32° to 100° F | 17 5/8" | Ungrounded | 1/2 | NPT | Male | 3/4 | NPT | Female | 4mA-20mA | 8V DC-35V DC | IP68, NEC Class I Divisions 1, 2 Groups B, C, D, NEC Class II Divisions 1, 2 Groups E, F, G, NEC Class III Divisions 1, 2, NEMA 4X | 00000000 | 000000 |
Infrared Thermometer Transmitters
Monitor the temperature of molten steel, furnaces, glass, and other hazardous surfaces without touching them. A built-in transmitter reads surface energy levels and converts them to analog and digital output values that can be read by a receiving device, such as a PLC. Because of this, you can use these transmitters for measuring and switching applications.
Adjust set points, emissivity range, and other settings on-site using the buttons on the transmitters. Connect transmitters to an IO-link controller (not included) to change settings remotely and alert you to errors on PLCs and human-machine interfaces.
Plug these transmitters into shielded M12 sockets since they're extremely prone to signal interference. These transmitters connect using two wires to send a 4-20mA current output and four wires to use the switching output and IO-link. Connect to pin 5 to utilize the test function to verify that the transmitter's signal processing is working correctly. To view transmitter wiring diagrams, select a part number and click Product Detail.
Their lenses resist scratches, which could cause transmitters to lose focus. All are IP-rated for protection against dust and low-pressure jets of water. Made of 303 stainless steel, these transmitters resist corrosion.
Transmitters can be used on all surfaces. For best results when measuring at an angle or working on round or uneven surfaces, use transmitters with laser sight.
Transmitters with a wavelength range of 0.78–1.06 microns are best for use with glass. Use transmitters with a wavelength range of 1–1.7 microns on metal, ceramics, and graphite. Transmitters with a wavelength range of 8–14 microns are useful for plastic, fabrics, food products, and other metal-free surfaces.
Add accessories to protect your infrared thermometer transmitter in hot or dirty environments. Air purges flush out dust, moisture, and other contaminants on transmitter lenses that can interfere with infrared radiation focus and cause inaccurate readings. Cooling jackets connect to a compressed air or water line to keep temperature transmitters from overheating. Protective covers prevent dirt buildup and excessive exposure to light, which can cause transmitters to lose focus. Insulating tubes prevent overheating by protecting thermometers against heat from mounting brackets or other surfaces.
For technical drawings and 3-D models, click on a part number.



Transmitters | Mounting Brackets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wavelength Range, microns | Temperature Range | Resolution | Accuracy | Digital Display Type | Emissivity | Response Time, sec. | Length | Diameter | Housing Material | Output Type | Each | Each | ||
Bracket Mount with Scratch-Resistant Lens | ||||||||||||||
0.78 - 1.06 | 932° to 4532° F/500° to 2500° C | 1° F/1° C | ±0.3% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 000000000 | 00000000 | 000000 |
1 - 1.7 | 482° to 2912° F/250° to 1600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
8 - 14 | 32° to 1831° F/0° to 1000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 7 1/2" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
Bracket Mount with Scratch-Resistant Lens and Laser Sight | ||||||||||||||
1 - 1.7 | 482° to 2912° F/250° to 1600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 9 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
8 - 14 | 32° to 1831° F/0° to 1000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 8 1/8" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
Hazardous Location Infrared Thermometers

These thermometers are rated for environments where hazardous material is present. They measure the temperature of surfaces without making contact and are often used to locate and diagnose problems in electrical, heating, and ventilation systems. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Warning: These infrared thermometers are not intended for medical use. Use Non-Contact Forehead Thermometers for medical use.
Batteries | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution | Accuracy | Max. Working Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Environmental Rating | Included | Size | No. Required | Each | |
For Dark, Dull Surfaces | ||||||||||||||
Fixed Emissivity | ||||||||||||||
0° to 752° F/-18° to 400° C | 0.2/0.2 | ±2% | 8 | 0.95 | 0.5 | 6" | 1 1/2" | Plastic | IEC Zone 1 Groups IIC, IIB, IIA | Yes | 9V | 1 | 0000000 | 0000000 |
For Dark, Dull, Light, Shiny Surfaces | ||||||||||||||
Adjustable Emissivity | ||||||||||||||
-40° to 1472° F/-40° to 800° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 0.5 | 7" | 2" | Plastic | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA | Yes | AAA | 2 | 0000000 | 00000000 |
Pipe-Mount Hazardous Location Thermometers

Mount this thermometer on pipes in environments with flammable gases, combustible dust, and ignitable fibers. It is FM approved for Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. Enclosure meets NEMA 4X for indoor/outdoor use and resistance to corrosive fluids, splashing water, and dust. It requires a mounting bracket (sold separately).
For technical drawings and 3-D models, click on a part number.
Material | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | For Probe Type | Probe Connection | Housing | Lens | Environmental Rating | Batteries Included | Each | |
-58° to 1832° F/-50° to 1000° C | .0001/.0001 | ±1° F/ ±1° C | J, K, RTD | Wire Leads | Aluminum | Glass | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IP68 NEMA 4X | No | 0000000 | 0000000 |
4 Nuts, 4 Washers | 0000000 | Each | 000000 |
Noncontact Infrared Temperature Sensors
Monitor the temperature of hazardous, sensitive, and hard-to-reach surfaces without touching them. IP or NEMA rated, these sensors are protected against dust and washdowns.
Sensors for nonmetal surfaces measure the temperature of plastics, fabrics, ceramics, and hot adhesives.
Sensors for metal surfaces measure the temperature of both solid metals, such as heating elements, and molten metals.
Sensors with a thermocouple output communicate with devices that read thermocouple signals, so they work as replacements for thermocouples with the same output type.
Sensors with a micro USB cord and terminal block connect to your computer. Use the downloadable software to change the measurement temperature range and the output scale.
Secure your sensor with a mounting bracket or mounting stud. Mounting brackets attach to flat surfaces. Mounting studs thread into holes.
Air purges flush dust, moisture, and other contaminants from the sensor lens to prevent inaccurate readings.

Sensor | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Measuring Range, °F | Min. Object Size Detected | Max. Sensing Distance | Wavelength, microns | Resolution | Accuracy | Response Time, sec. | Lg. | Dia. | Cable Lg., ft. | Input Voltage | For Panel Cutout Dia. | Thread Size | Includes | Environmental Rating | Each | |
0-5V DC, 0-10V DC, Thermocouple Type K Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
-40° to 1,886° | 0.24" | 2.6ft. | 8-14 | 15:1 | ±3° F below 200° F ±1.5% above 200° F | 0.025 | 3 1/2" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65 | 0000000 | 0000000 |
4-20 mA Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
-58° to 1,886° | 0.26" | 3.2ft. | 8-14 | 15:1 | ±2° F below 200° F ±1% above 200° F | 0.014 | 1 1/8" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65, NEMA 4 | 0000000 | 000000 |
Thermocouple Type J Output Signal | ||||||||||||||||
Fixed Emissivity (0.95) | ||||||||||||||||
32° to 662° | 0.17" | 4ft. | 7-18 | 4:1 | ±6° F below 241° F ±5% between 241° F to 440° F Not Rated above 440° F | 0.35 | 3 1/2" | 3/4" | 3.25 | 12V DC-24V DC | 3/4" | 3/4"-16 | __ | IP65, NEMA 4 | 00000000 | 000000 |
86° to 932° | 0.17" | 4ft. | 7-18 | 4:1 | ±10° F below 212° F ±6° F between 212° to 300° F ±2% above 300° F | 0.35 | 3 1/2" | 3/4" | 3.25 | 12V DC-24V DC | 3/4" | 3/4"-16 | __ | IP65, NEMA 4 | 00000000 | 000000 |

Sensor | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Measuring Range, °F | Min. Object Size Detected | Max. Sensing Distance | Wavelength, microns | Resolution | Accuracy | Response Time, sec. | Lg. | Dia. | Cable Lg., ft. | Input Voltage | For Panel Cutout Dia. | Thread Size | Includes | Environmental Rating | Each | |
4-20 mA Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
122° to 662° | 0.26" | 3.6ft. | 2.3 | 22:1 | ±(0.3% of Temperature Measured + 3.6° F) | 0.02 | 1 1/4" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65, NEMA 4 | 0000000 | 0000000 |

Thread | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Sensor Dia. | Size | Pitch, mm | Lg. | Ht. | Wd. | Dp. | Material | Each | |
1/2" | M12 | 1 | 1/4" | 7/8" | 3/4" | 1/2" | 303 Stainless Steel | 0000000 | 000000 |

For Sensor Connection Thread | ||||
---|---|---|---|---|
Size | Pitch | Material | Each | |
M12 | 1 mm | 303 Stainless Steel | 0000000 | 000000 |
Remote-Sensor Hazardous Location Line-Voltage Thermostats

Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present. Thermostats are rated Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups E, F, and G.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Sensor Cord Lg., ft. | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Environmental Rating | Each | |
For Air Conditioners and Heaters | |||||||||||||
120V AC-277V AC | 22 | 20° to 80° | SPDT | 5 7/8" | 3" | 3 1/4" | 6 | No | 3/8" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | 0000000 | 0000000 |
Hazardous Location Line-Voltage Thermostats

Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present. Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Environmental Rating | Each | |
For Air Conditioners and Heaters | ||||||||||||
24V AC-277V AC | 22 | 50° to 90° | SPDT | 5 3/4" | 6 3/8" | 5 5/8" | No | 1/4" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 | 0000000 | 0000000 |
24V AC-277V AC | 22 | 50° to 90° | DPDT | 5 3/4" | 6 3/8" | 5 5/8" | No | 1/4" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 | 0000000 | 000000 |