Filter by
For Use With
System of Measurement
Heating Element Material
Heating Element Length
Current
Temperature Control Type
Watt Density
Heater Type
Connects To
Body Material
Fitting Connection
Thread Type
U.S.–Mexico–Canada Agreement (USMCA) Qualifying
Export Control Classification Number (ECCN)
DFARS Specialty Metals
Flow-Through Heating Elements for Air
Heating Element | Without Temperature Control | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wattage, W | Watt Density, W/in | Lg. | Wd. | No. of | Max. Air Input Temp., ° F | Max. Air Output Temperature, ° F | Max. Input Airflow, ft³/min | Pipe Size | Thread Type | Gender | Electrical Connection Type | Wire Connection | For Use With | Current, amp | Each | |||
Ceramic Heating Element with Copper Body | ||||||||||||||||||
120V AC, Single Phase | ||||||||||||||||||
| 400 | 89 | 5" | 1/2" | 1 | 250 | 1,000 | 10 | 1/8 | NPT | Female | Hardwire | Wire Leads | Air | 3.3 | 6586N11 | 0000000 | ||
| 650 | 87 | 8" | 1/2" | 1 | 250 | 1,000 | 10 | 1/8 | NPT | Female | Hardwire | Wire Leads | Air | 5.4 | 6586N12 | 000000 | ||
| 750 | 136 | 6" | 3/4" | 1 | 250 | 1,000 | 20 | 1/4 | NPT | Female | Hardwire | Wire Leads | Air | 6.2 | 6586N13 | 000000 | ||
| 1,250 | 132 | 10" | 3/4" | 1 | 250 | 1,000 | 20 | 1/4 | NPT | Female | Hardwire | Wire Leads | Air | 10.4 | 6586N14 | 000000 | ||
240V AC, Single Phase | ||||||||||||||||||
| 1,000 | 182 | 6" | 1 1/4" | 1 | 250 | 1,000 | 50 | 1/2 | NPT | Female | Hardwire | Wire Leads | Air | 4.1 | 6586N15 | 000000 | ||
| 2,500 | 333 | 8" | 1 1/4" | 1 | 250 | 1,000 | 50 | 1/2 | NPT | Female | Hardwire | Wire Leads | Air | 10.4 | 6586N16 | 000000 | ||
| 4,000 | 348 | 12" | 1 1/4" | 1 | 250 | 1,000 | 50 | 1/2 | NPT | Female | Hardwire | Wire Leads | Air | 16.6 | 6586N17 | 000000 | ||
Flow-Through Heating Elements for Water
Heating Element | Temp. Control | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wattage, W | Watt Density, W/in² | Current, amp | Lg. | Wd. | No. of | Method | Range, ° F | Pipe Size | Thread Type | Gender | Wire Connection | Each | |||
Copper Heating Element with Bronze Body | |||||||||||||||
120V AC, Single Phase | |||||||||||||||
| 1,500 | 34 | 12.5 | 11 1/4" | 4" | 1 | Screw | 60 to 180 | 1 | NPT | Female | Screw Terminal | 3595K31 | 000000000 | ||
| 2,000 | 47 | 16.7 | 11 3/4" | 4" | 1 | Screw | 60 to 180 | 1 | NPT | Female | Screw Terminal | 3595K32 | 00000000 | ||
240V AC, Single Phase | |||||||||||||||
| 3,000 | 51 | 12.5 | 16" | 4" | 1 | Screw | 60 to 180 | 1 | NPT | Female | Screw Terminal | 3595K33 | 00000000 | ||
Incoloy Nickel Heating Element with Aluminum Body | |||||||||||||||
480V AC, Three Phase | |||||||||||||||
| 6,000 | 50 | 7.3 | 28 13/16" | 5 5/8" | 3 | Dial | 60 to 250 | 1 | NPT | Male | Wire Leads | 35705K112 | 00000000 | ||
| 12,000 | 50 | 14.5 | 39 9/16" | 5 5/8" | 3 | Dial | 60 to 250 | 1 | NPT | Male | Wire Leads | 35705K122 | 00000000 | ||
| 18,000 | 50 | 21.7 | 51 5/16" | 5 5/8" | 3 | Dial | 60 to 250 | 1 | NPT | Male | Wire Leads | 35705K132 | 00000000 | ||
| 24,000 | 50 | 29 | 37 5/16" | 8" | 6 | Dial | 60 to 250 | 2 | NPT | Male | Wire Leads | 35705K152 | 00000000 | ||
| 40,000 | 50 | 48 | 55 3/4" | 8" | 6 | Dial | 60 to 250 | 2 | NPT | Male | Wire Leads | 35705K162 | 00000000 | ||
Flow-Through Heating Elements for Chemical Solutions
Heating Element | Adjustable Thermostat (90° F to 190° F) | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wattage, W | Watt Density, W/in² | Lg. | Wd. | No. of | Pipe Size | Thread Type | Gender | Electrical Connection Type | Wire Connection | NEMA Type | Cord Lg., ft. | Enclosure Rating | For Use With | Current, amp | Temp. Control Method | Each | |||
Titanium Heating Element with 304 Stainless Steel Body | |||||||||||||||||||
120V AC, Single Phase | |||||||||||||||||||
| 1,500 | 42 | 15" | 5.7" | 1 | 1 1/2 | NPT | Female | Plug In | — | 5-15 | 6 | NEMA 1 | Ammonium Hydroxide Deionized Water Salt Water Water | 12.5 | Dial | 4745T41 | 0000000 | ||
240V AC, Single Phase | |||||||||||||||||||
| 3,000 | 84 | 15" | 5.7" | 1 | 1 1/2 | NPT | Female | Hardwire | Wire Leads | — | — | NEMA 1 | Ammonium Hydroxide Deionized Water Salt Water Water | 12.5 | Dial | 4745T43 | 000000 | ||
| 4,000 | 112 | 15" | 5.7" | 1 | 1 1/2 | NPT | Female | Hardwire | Wire Leads | — | — | NEMA 1 | Ammonium Hydroxide Deionized Water Salt Water Water | 16.7 | Dial | 4745T44 | 000000 | ||
| 6,000 | 167 | 15" | 5.7" | 1 | 1 1/2 | NPT | Female | Hardwire | Wire Leads | — | — | NEMA 1 | Ammonium Hydroxide Deionized Water Salt Water Water | 25 | Dial | 4745T46 | 000000 | ||
Flow-Through Heating Elements for Coolant
Heating Element | Adjustable Thermostat (150° F to 560° F) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wattage, W | Watt Density, W/in² | Lg. | Wd. | No. of | Pipe Size | Thread Type | Gender | Electrical Connection Type | Wire Connection | For Use With | Current, amp | Temp. Control Method | Each | |||
Steel Heating Element with Steel Body | ||||||||||||||||
120V AC, Single Phase | ||||||||||||||||
| 500 | 17 | 8 3/8" | 4" | 1 | 1 | NPT | Female | Hardwire | Screw Terminal | Ethylene Glycol Water | 4.2 | Dial | 3595K61 | 000000000 | ||
| 750 | 17 | 13" | 4" | 1 | 1 | NPT | Female | Hardwire | Screw Terminal | Ethylene Glycol Water | 6.3 | Dial | 3595K62 | 00000000 | ||
240V AC, Single Phase | ||||||||||||||||