    Drop-In Immersion Heating Elements for Water

    Image of Product. Front orientation. Contains Annotated. Heating Elements. Drop-In Immersion Heating Elements for Water.
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Drop-In Immersion Heating Elements for Water.

    5-15

    Often used for temporary heating in sinks and pails, these heating elements have a circular base that sits at the bottom of containers to quickly and efficiently heat liquid through direct contact. Remove them from the container after heating its contents. The heating element is Incoloy for excellent corrosion resistance.
    Note: Immerse the heating element in liquid up to at least the minimum coverage level to prevent heating element failure.
    Heating Element
    Wattage,
    W
    Watt Density,
    W/in²
    Current,
    amp
    Lg.
    Dia.
    Min. Liquid
    Coverage
    Max. Submersion
    Dp.
    NEMA
    Type
    Cord Lg.,
    ft.
    Each
    Incoloy Nickel Heating Element
     
    120V AC, Single Phase
    1,15046.59.65 1/2"5"1 1/2"4"5-15
    5 1/23583K910000000
    1,15047.99.611 1/2"5"1 1/2"10"5-15
    5 1/23583K92000000
     

    Hanging Immersion Heating Elements for Chemical Solutions

    Image of Product. With 6" Lg. Heating Element. Front orientation. Contains Annotated. Heating Elements. Hanging Immersion Heating Elements for Chemical Solutions, Adjustable Thermostat, 6" Long Heating Element.
    Image of Product. With 14" Lg. Heating Element. Front orientation. Contains Annotated. Heating Elements. Hanging Immersion Heating Elements for Chemical Solutions, Adjustable Thermostat, 14" Long Heating Element.
    Image of Product. With 20" Lg. Heating Element. Front orientation. Contains Annotated. Heating Elements. Hanging Immersion Heating Elements for Chemical Solutions, Adjustable Thermostat, 20" Long Heating Element.

    With 6" Lg. Heating

    Element

    With 14" Lg. Heating

    Element

    With 20" Lg.

    Heating

    Element

    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Hanging Immersion Heating Elements for Chemical Solutions.

    5-15

    Hook these heating elements on the side of small drums and pails to quickly and efficiently heat liquid through direct contact. All are for use in metal containers; they should not be used in plastic containers. An adjustable thermostat automatically turns the heating element on when the temperature drops below the set temperature and off when it rises above the set temperature. Adjust the set temperature with the dial. The heating element is 316 stainless steel for excellent resistance to harsh chemicals.
    Note: Immerse the heating element in liquid up to at least the minimum coverage level to prevent heater failure.
    Heating
    Element
    For Container
    Cap. Range, gal.
    Wattage,
    W
    Watt Density,
    W/in²
    Voltage,
    V AC
    Electrical
    Phase
    Current,
    amp
    Dia.
    Wd.
    Min. Liquid
    Coverage
    Overall
    Lg.
    Temp. Control
    Method
    NEMA
    Type
    Cord Lg.,
    ft.
    For Use With
    Each
    Adjustable Thermostat, 60° F to 250° F Temperature Control
     
    6" Lg. 316 Stainless Steel Heating Element
    1 to 550036120Single4.31 3/8"4 1/2"9 3/4"Dial5-15
    6Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Motor Oil
    Water
    3551K350000000
    1 to 51,10080120Single9.61 3/8"4 1/2"9 3/4"Dial5-15
    6Ammonium Hydroxide
    Deionized Water
    Motor Oil
    Water
    3551K36000000
     
    14" Lg. 316 Stainless Steel Heating Element
    5 to 101,50019120Single1313"5"14 1/2"Dial5-15
    6Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Motor Oil
    Phosphoric Acid
    Water
    35605K75000000
    5 to 101,50023120Single1310 1/2"5"14 1/2"Dial5-15
    6Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Motor Oil
    Water
    35605K76000000
    5 to 101,50036120Single137"5"14 1/2"Dial5-15
    6Ammonium Hydroxide
    Deionized Water
    Motor Oil
    Water
    35605K77000000
     
    20" Lg. 316 Stainless Steel Heating Element
    5 to 1050012120Single4.31 3/8"18 1/2"23 1/2"Dial5-15
    6Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Motor Oil
    Nitric Acid
    Phosphoric Acid
    Sodium Hydroxide (Caustic Soda)
    Water
    3551K37000000
    5 to 101,10027120Single9.61 3/8"18 1/2"23 1/2"Dial5-15
    6Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Motor Oil
    Nitric Acid
    Phosphoric Acid
    Sodium Hydroxide (Caustic Soda)
    Water
    3551K38000000
     

    Flow-Through Heating Elements for Chemical Solutions

    Image of Product. Front orientation. Heating Elements. Flow-Through Heating Elements for Chemical Solutions.
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Flow-Through Heating Elements for Chemical Solutions.

    5-15

    Also known as circulation heating elements, these install directly into pipelines to quickly and efficiently heat liquid through direct contact. All are designed to heat chemical solutions at much higher watt densities than other immersion heating elements without damaging the heating element. An adjustable thermostat automatically turns the heating element on when the temperature drops below the set temperature and off when it rises above the set temperature. Adjust the set temperature with the dial. Heating elements automatically shut off at 202° F to prevent fire and heating element burnout. The heating element is titanium for excellent resistance to harsh chemicals.
    Heating
    Element
    Adjustable Thermostat
    (90° F to 190° F)
    Wattage,
    W
    Watt Density,
    W/in²
    Lg.
    Wd.
    No.
    of
    Pipe
    Size
    Thread
    Type
    Gender
    Electrical
    Connection Type
    NEMA
    Type
    Cord Lg.,
    ft.
    Enclosure
    Rating
    For Use With
    Current,
    amp
    Temp. Control
    Method
    Each
    Titanium Heating Element with 304 Stainless Steel Body
     
    120V AC, Single Phase
    1,5004215"5.7"11 1/2
    NPT
    FemalePlug In5-15
    6NEMA 1
    Ammonium Hydroxide
    Deionized Water
    Salt Water
    Water
    12.5Dial4745T410000000
     

    Bolt-On Immersion Heating Elements with Overheat Protection for Chemical Solutions

    Image of ProductInUse. Front orientation. Contains Annotated. Heating Elements. Bolt-On Immersion Heating Elements with Overheat Protection for Chemical Solutions, Adjustable Thermostat, 1 Heating Element.
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Bolt-On Immersion Heating Elements with Overheat Protection for Chemical Solutions.

    Adjustable Thermostat

    1 Heating Element

    5-15

    A replaceable fuse cuts off power if the heating element reaches 190° F to prevent burnout and premature failure. Bolt the flange to the top of containers. Heating elements make direct liquid contact for fast and efficient heating. The heating element is 304 stainless steel for good resistance to harsh chemicals.
    Note: Immerse the heating element in liquid up to at least the minimum coverage level to prevent heating element failure.
    Adjustable Thermostat—Heating elements with an adjustable thermostat automatically turn on when the temperature drops below the set temperature and off when it rises above the set temperature. Adjust the set temperature with the digital keypad.
    Heating Element
    Flange
    Wattage,
    W
    Watt Density,
    W/in²
    Current,
    amp
    Lg.
    Wd.
    No.
    of
    Min. Liquid
    Coverage
    NEMA
    Type
    Bolt Hole
    Dia.
    No. of Bolt
    Holes
    For Use With
    Each
    Adjustable Thermostat (32° F to 302° F)—304 Stainless Steel Heating Element and 304 Stainless Steel Body
     
    120V AC, Single Phase
    500354.211"1 1/4"19"5-15
    1/2"2Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Hydraulic Oil
    Machine Oil
    Motor Oil
    Nitric Acid
    Phosphoric Acid
    Propylene Glycol
    Salt Water
    Soap Solutions
    Sodium Hydroxide (Caustic Soda)
    Water
    3616K110000000
    1,000358.311"1 1/4"19"5-15
    1/2"2Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Hydraulic Oil
    Machine Oil
    Motor Oil
    Nitric Acid
    Phosphoric Acid
    Propylene Glycol
    Salt Water
    Soap Solutions
    Sodium Hydroxide (Caustic Soda)
    Water
    3616K12000000
    1,5001712.528"2"112"5-15
    1/2"2Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Hydraulic Oil
    Machine Oil
    Motor Oil
    Nitric Acid
    Phosphoric Acid
    Propylene Glycol
    Salt Water
    Soap Solutions
    Sodium Hydroxide (Caustic Soda)
    Water
    3616K34000000
    1,5003512.517"2"112"5-15
    1/2"2Ammonium Hydroxide
    Deionized Water
    Ethylene Glycol
    Hydraulic Oil
    Machine Oil
    Motor Oil
    Nitric Acid
    Phosphoric Acid
    Propylene Glycol
    Salt Water
    Soap Solutions
    Sodium Hydroxide (Caustic Soda)
    Water
    3616K33000000
     
    Fuses

    Portable Large-Space Gas Heaters

    Image of Product. Style B. Front orientation. Style B. Portable Large-Space Gas Heaters .
    Image of Specification. NEMA 5-15. Front orientation. NEMA 5-15. Portable Large-Space Gas Heaters .

    Style B

    NEMA

    5-15

    Built for big jobs, these are powerful space heaters.
    All have a safety shut-off that cuts the gas supply if the flame goes out.
    Propane Heater—Propane heaters have a regulator with a NGO connection (the same connection between your gas grill and propane tank).
    Knob Control—On heaters controlled with a knob, turn the knob to adjust heat output.
    Thermostat Control—Heaters with a built-in thermostat allow you to control the temperature.
    Style B—Style B heaters have an electronic spark ignition and are good for drafty areas where a pilot light could be extinguished.
    Inlet
    Overall
    Style
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow,
    ft³/min
    Req. Propane
    Tank Size, lb.
    Max. Fuel
    Consumption
    Pipe
    Size
    Thread
    Type
    Gender
    Current,
    amp
    Cord
    Lg.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Includes
    Each
    Natural Gas Heaters with Thermostat (40° F to 105° F)
     
    Electronic Spark Ignition—120V AC, Single Phase, Three-Blade Plug (5-15)
    B155,00020,660 cu. ft. @ 10° F
    10,330 cu. ft. @ 20° F
    6,880 cu. ft. @ 30° F
    5,160 cu. ft. @ 40° F
    625155 ft³/hr1/2
    NPT
    Female2.14"16"9"24"Steel1722K240000000
     
    Propane Heaters with Knob
     
    Electronic Spark Ignition—120V AC, Single Phase, Three-Blade Plug (5-15)
    B125,00016,660 cu. ft. @ 10° F
    8,330 cu. ft. @ 20° F
    5,550 cu. ft. @ 30° F
    4,160 cu. ft. @ 40° F
    4001006 lb/hrNGO
    0.710"16"12"26"Steel15-ft. Hose1722K58000000
     
    Propane Heaters with Thermostat (40° F to 105° F)
     
    Electronic Spark Ignition—120V AC, Single Phase, Three-Blade Plug (5-15)
    B170,00022,660 cu. ft. @ 10° F
    11,330 cu. ft. @ 20° F
    7,550 cu. ft. @ 30° F
    5,660 cu. ft. @ 40° F
    6251008 lb/hrNGO
    2.14"16"9"24"Steel10-ft. Hose1722K14000000
    B400,00053,330 cu. ft. @ 10° F
    26,660 cu. ft. @ 20° F
    17,770 cu. ft. @ 30° F
    13,330 cu. ft. @ 40° F
    1,58050018.5 lb/hrNGO
    1.54"22"13"35"Steel10-ft. Hose1722K16000000
     

    Mobile Large-Space Kerosene and Diesel Heaters

    Image of Specification. NEMA 5-15. Front orientation. NEMA 5-15. Mobile Large-Space Kerosene and Diesel Heaters .

    NEMA

    5-15

    Roll these powerful space heaters to where you need heat for big jobs. All have a built-in thermostat.
    The electronic spark ignition makes them good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
    With On/Off Switch and Thermostat
    Image of Product. Front orientation. Space Heaters. Mobile Large-Space Kerosene and Diesel Heaters .
    Image of Product. Front orientation. Air Intake Filters. Mobile Large-Space Kerosene and Diesel Heaters .

    Replacement Air Intake

    Filters

    Heaters
    Replacement Air
    Intake Filters
    Overall
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow,
    ft³/min
    Max. Fuel Consumption,
    gph
    Fuel Cap.,
    gal.
    Current,
    amp
    Cord
    Lg.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Certification
    Each
    Each
    Electronic Spark Ignition—120V AC, Single Phase, Three-Blade Plug (5-15)
     
    40° F to 105° F Temperature Setting
    125,00016,660 cu. ft. @ 10° F
    8,330 cu. ft. @ 20° F
    5,550 cu. ft. @ 30° F
    4,160 cu. ft. @ 40° F
    5201102.54"25"23"38"SteelCSA Certified
    1744K200000001744K84000000
    175,00023,330 cu. ft. @ 10° F
    11,660 cu. ft. @ 20° F
    7,770 cu. ft. @ 30° F
    5,830 cu. ft. @ 40° F
    6001.3133.24"27"24"44"SteelCSA Certified
    1744K260000001744K8400000
    650,00086,660 cu. ft. @ 10° F
    43,330 cu. ft. @ 20° F
    28,880 cu. ft. @ 30° F
    21,660 cu. ft. @ 40° F
    3,6005507.14"49"31"70"SteelCSA Certified
    1744K7500000000———0
     

    Floating Immersion Heating Elements for Water

    Image of Product. Front orientation. Heating Elements. Floating Immersion Heating Elements for Water.
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Floating Immersion Heating Elements for Water.

    5-15

    Often used for freeze protection in outdoor containers, these heating elements float on the water’s surface and automatically turn on when the water temperature drops below 45° F and turn off when it rises above 65° F. They are for use in metal containers. All have an Incoloy heating element for excellent corrosion resistance.
    O'all
    Nonadjustable
    Thermostat (45° F to 65° F)
    Wattage,
    W
    Watt Density,
    W/in²
    Dia.
    Ht.
    No. of Heating
    Elements
    Electrical
    Connection Type
    NEMA
    Type
    Cord Lg.,
    ft.
    Certification
    For Use
    With
    Current,
    amp
    Each
    Incoloy Nickel Heating Element with ABS Body
     
    120V AC, Single Phase
    1,000288 1/8"4"1Plug In5-15
    6UL Listed
    Water8.33639K47000000
    1,500398 1/8"4"1Plug In5-15
    6UL Listed
    Water12.53639K4800000
     
    Heating Element Guards

    Hanging Immersion Heating Elements for Coolant

    Use the attached bracket to hook these heating elements on the side of drums and in bung openings. They quickly and efficiently heat liquid through direct contact. With a lower watt density than heating elements for water or chemicals, these heating elements can heat coolant without creating hot spots or damaging the heating element. An adjustable thermostat automatically turns the heating element on when the temperature drops below the set temperature and off when it rises above the set temperature. Adjust the set temperature with the dial. Heating elements are for use in metal containers; they should not be used in plastic containers.
    Note: Immerse the heating element in liquid up to at least the minimum coverage level to prevent heating element failure.
    Hanging Mount
    Image of Product. Front orientation. Contains Annotated. Heating Elements. Hanging Immersion Heating Elements for Coolant, Hanging Mount.
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Hanging Immersion Heating Elements for Coolant.

    5-15

    Hanging heating elements have a bracket to hook on the side of containers.
    316 Stainless Steel Heating Element—Stainless steel heating elements have good corrosion resistance.
    Heating
    Element
    For Container
    Cap., gal.
    Wattage,
    W
    Watt Density,
    W/in²
    Voltage,
    V AC
    Electrical
    Phase
    Current,
    amp
    Lg.
    Wd.
    Min. Liquid
    Coverage
    Temp. Control
    Range, ° F
    Electrical
    Connection Type
    NEMA
    Type
    Cord Lg.,
    ft.
    For Use With
    Each
    316 Stainless Steel Heating Element
    8 to 201,00014120Single8.326"13"4 1/2"60 to 250Plug In5-15
    6Ethylene Glycol
    Water
    35505K310000000
    8 to 201,50016120Single12.526"17"4 1/2"60 to 250Plug In5-15
    6Ethylene Glycol
    Water
    35505K32000000
     

    Portable Small-Space Electric Heaters

    Carry these heaters to offices, workstations, and other small spaces. All have a built-in thermostat.
    With On/Off Switch and Thermostat
    Image of Product. Front orientation. Space Heaters. Portable Small-Space Electric Heaters , With On/Off Switch and Thermostat, 5,100 BTU/hr Heat Output, Steel Housing.
    Image of Specification. NEMA 5-15. Front orientation. NEMA 5-15. Portable Small-Space Electric Heaters .

    5,100 BTU/hr Heat

    Output, Steel Housing

    NEMA

    5-15

    Overall
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow,
    ft³/min
    Wattage,
    W
    Current,
    amp
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Certification
    Each
    120V AC, Single Phase, Three-Blade Plug (5-15)
     
    0° F to 80° F Temperature Setting
    5,100750 cu. ft. @ 10° F
    370 cu. ft. @ 20° F
    250 cu. ft. @ 30° F
    190 cu. ft. @ 40° F
    1201,50012.5611"9"13"SteelETL Listed, UL Listed
    1810K120000000
     

    Portable Large-Space Kerosene and Diesel Heaters

    Built for big jobs, this is a powerful space heater. It has a built-in thermostat.
    The electronic spark ignition makes it good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
    With On/Off Switch and Thermostat
    Image of Product. Front orientation. Space Heaters. Portable Large-Space Kerosene and Diesel Heaters .
    Image of Specification. NEMA 5-15. Front orientation. NEMA 5-15. Portable Large-Space Kerosene and Diesel Heaters .
    Image of Product. Front orientation. Air Intake Filters. Portable Large-Space Kerosene and Diesel Heaters .

    NEMA

    5-15

    Replacement Air Intake

    Filters

    Heaters
    Replacement Air
    Intake Filters
    Overall
    Heat Output,
    BTU/hr
    Max. Space Heated @ Temp. Change
    Airflow,
    ft³/min
    Max. Fuel Consumption,
    gph
    Fuel Cap.,
    gal.
    Current,
    amp
    Cord
    Lg.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Certification
    Each
    Each
    Electronic Spark Ignition—120V AC, Single Phase, Three-Blade Plug (5-15)
     
    40° F to 105° F Temperature Setting
    75,00010,000 cu. ft. @ 10° F
    5,000 cu. ft. @ 20° F
    3,330 cu. ft. @ 30° F
    2,500 cu. ft. @ 40° F
    2650.651.64"17"12"32"SteelCSA Certified
    1744K300000001744K84000000
     
    back to top