About Gas Regulators
More
About Air Preparation
More
Panel-Mount Ultra-High-Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Nitrogen, Argon, Helium
- Temperature Range: -40° to 165° F
These valves are rated for inlet pressures up to 6,000 psi. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Threads below the adjustment knob and an included mounting bracket let you install these valves in instrument panels. They have two gauge ports. An internal strainer traps debris.
Inlet | Outlet | Gauge Port | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Panel Cutout Dia. | Specifications Met | Choose an Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||||
Brass Body—Polyimide Seal | ||||||||||||
| 1/4 | Side | 6,000 | 1/4 | Side | 1/4 | Side | 2 1/8" | 2 1/4" | ASME B31.3 | 0000000 | 000000000 | |
Corrosion-Resistant Panel-Mount Ultra-High-Pressure-Regulating
Valves for Water, Air, and Inert Gas

- For Use With: Water, Air, Inert Gas
- Temperature Range: 32° to 165° F
To regulate inlet pressures up to 6,000 psi in wet conditions and harsh environments, these valves have a 316 stainless steel body for exceptional corrosion resistance. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have threads below the adjustment knob and come with a panel-mount nut. All have two gauge ports. They are no-bleed style, so they keep the process gases contained in the valve.
Inlet | Outlet | Gauge Port | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Panel Cutout Dia. | Choose an Outlet Pressure Range, psi | Each | |
NPT Female | |||||||||||
316 Stainless Steel Body—PTFE Seal | |||||||||||
| 1/4 | Side | 6,000 | 1/4 | Side | 1/4 | Side | 2" | 1.37" | 0000000 | 0000000 | |
Panel-Mount High-Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Nitrogen, Argon, Helium
- Temperature Range: -40° to 165° F
Withstand inlet pressures up to 3,500 psi. These valves automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have threads below the adjustment knob and come with a panel-mount nut. All have two gauge ports. An internal strainer traps debris.
Inlet | Outlet | Gauge Port | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Panel Cutout Dia. | Specifications Met | Choose an Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||||
Brass Body—316 Stainless Steel Diaphragm and PTFE Seal | ||||||||||||
| 1/4 | Side | 3,500 | 1/4 | Side | 1/4 | Side | 2" | 1 3/8" | ASME B31.3 | 0000000 | 0000000 | |
Tank-Mount High-Pressure-Regulating Valves for Air and Inert Gas
- For Use With: See Table
- Temperature Range: -20° to 120° F
Often used for pressure-vessel testing and other high-pressure applications, these valves can handle at least seven times the outlet pressure of standard tank-mount pressure-regulating valves. They automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.


Inlet | Outlet | Material | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Shape | Body | Seal | Each | |
NGO Female Inlet × Swagelok® Female Outlet | ||||||||||||
| CGA 677 | Side | Left Hand | 0 to 7,500 | Single | 1/4" | Bottom | 300 to 4,500 | 90° Elbow | Brass | PCTFE | 0000000 | 000000000 |
NGO Male Inlet × Swagelok® Female Outlet | ||||||||||||
| CGA 580 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Bottom | 200 to 3,000 | 90° Elbow | Brass | PCTFE | 0000000 | 000000 |

Inlet | Outlet | Material | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Pressure Adjustment Method | Shape | Body | Seal | Diaphragm | Each | |
NGO Female Inlet × Swagelok® Female Outlet | ||||||||||||||
| CGA 540 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 1,500 | Knob | Straight | Brass | PCTFE | Neoprene | 0000000 | 0000000 |
| CGA 540 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 2,500 | Knob | Straight | Brass | PCTFE | Neoprene | 0000000 | 000000 |

Inlet | Outlet | Material | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Pressure Adjustment Method | Shape | Body | Seal | Diaphragm | Each | |
NGO Male Inlet × Swagelok® Female Outlet | ||||||||||||||
| CGA 590 | Side | Left Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 1,500 | Knob | Straight | Brass | PCTFE | Polyurethane | 0000000 | 0000000 |
| CGA 590 | Side | Left Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 2,500 | Knob | Straight | Brass | PCTFE | Polyurethane | 0000000 | 000000 |

Inlet | Outlet | Material | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Pressure Adjustment Method | Shape | Body | Seal | Diaphragm | Each | |
NGO Female Inlet × Swagelok® Female Outlet | ||||||||||||||
| CGA 346 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 1,500 | Knob | Straight | Brass | PCTFE | Polyurethane | 0000000 | 0000000 |
| CGA 346 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 2,500 | Knob | Straight | Brass | PCTFE | Polyurethane | 0000000 | 000000 |
Miniature Ultra-High-Pressure-Regulating Valves for Water, Air, and Inert Gas

- For Use With: Water, Air, Argon
- Temperature Range: -15° to 165° F
For extremely high-pressure applications in tight spots, these valves handle the same inlet pressures as other ultra-high-pressure-regulating valves within a smaller footprint. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. All have two gauge ports. Body is nickel-plated aluminum for good corrosion resistance. Valves are no-bleed style, so they keep the process gas contained within the valve.
High-Pressure-Regulating Valves for Water, Oil, Air, and Inert Gas

- For Use With: Water, Oil, Air, Inert Gas
- Temperature Range: 32° to 300° F
Withstand more than six times the inlet pressure of standard pressure-regulating valves. These valves automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have a 303 stainless steel body for corrosion resistance in harsh environments.
Inlet | Outlet | |||||||
|---|---|---|---|---|---|---|---|---|
| Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Port-to-Port Lg. | Choose an Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||
303 Stainless Steel Body—PTFE Seal | ||||||||
| 2 | Side | 3,000 | 2 | Bottom | 3" | 0000000 | 000000000 | |
High-Flow Electronically-Controlled Precision
Compressed Air Regulators with Display


Keep an eye on the output pressure in high-flow applications—you can view and control it remotely or on the display at the source. These regulators translate electrical signals into steady output pressure that’s needed for precise, repeatable motion. As the input signal increases, the output pressure increases proportionally within the regulating range. Pair them with sensors that produce the required input signal current or voltage or with programmable logic controllers (PLCs) for automatic pressure adjustments.
All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure. Install them in your air line after your filters.
Regulators with an LED display let you choose from multiple views, including showing pressure scale in psi or bar, minimum pressure, and maximum pressure within the regulating range.
Mounting brackets (sold separately) allow you to attach the regulator to a wall or equipment.
Regulators | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Mounting Brackets | Connecting Cables | |||||||||||||||
| Pressure Regulating Range, psi | Input Signal Current, mA | Input Signal Voltage | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Wd. | Ht. | Housing Material | Max. Temp., °F | Electrical Connection Type | Environmental Rating | Each | Each | Each | |||
NPT Female Inlet and Outlet—LED Display | ||||||||||||||||||
±1.3% Regulating Accuracy | ||||||||||||||||||
| 0-145 | 4-20 | 0-10V DC | 1/2 | 1/2 | 120 scfm @ 100 psi | 152 | 3" | 7 1/2" | Aluminum | 120° | Plug | IP65 | 000000 | 0000000 | 0000000 | 000000 | 00000000 | 0000000 |
NPT Female Inlet and Outlet—LCD Display | ||||||||||||||||||
±0.8% Regulating Accuracy | ||||||||||||||||||
| 0-125 | __ | 0-10V DC | 1/4 | 1/4 | 90 scfm @ 100 psi | 150 | 2 3/8" | 6 3/8" | Aluminum | 125° | Hardwire | __ | 00000000 | 00000000 | 0000000 | 00000 | 000000 | 00 |
| 0-125 | __ | 0-10V DC | 1/2 | 1/2 | 100 scfm @ 100 psi | 150 | 2 3/8" | 6 3/8" | Aluminum | 125° | Hardwire | __ | 00000000 | 00000000 | 0000000 | 00000 | 000000 | 00 |
Hazardous Location Electronically-Controlled
Precision Compressed Air Regulators with Display
Designed to prevent sparks, these regulators are safe to use in IEC Zone 2, Groups IIC, IIB, and IIA hazardous locations. Set outlet pressure right on the display or adjust them remotely. For remote adjustments, pair them with either sensors or programmable logic controllers (PLCs). Sensors will produce the required input signal current based on system feedback. For more complex setups, PLCs will take timing, logic, or sensor inputs into consideration. These regulators translate electrical signals into steady output pressure for precise, repeatable motion. As the input signal increases, the output pressure increases proportionally within the regulating range. All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure. Install these regulators in your air line after filters, then use a cable (sold separately) to connect to your PLC or network.
The display shows outlet pressure, pressure scale (psi or bar), minimum pressure, and maximum pressure (within the regulating range).
Regulators with IO link allow you to change settings remotely, monitor performance, and run diagnostics when connected to your industrial network.

Regulators | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Connecting Cables | |||||||||||||||
| Pressure Regulating Range, psi | Input Signal Current, mA | Input Signal Voltage | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Wd. | Ht. | Housing Material | Max. Temp., °F | Electrical Connection Type | Environmental Rating | Specifications Met | Each | Each | ||
NPT Female Inlet and Outlet—LED Display | |||||||||||||||||
±0.2% Regulating Accuracy | |||||||||||||||||
| 0.75-150 | 4-20 | 0-10V DC | 1/8 | 1/8 | 51 scfm @ 100 psi | 155 | 1 3/4" | 5 1/4" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 0000000 | 0000000 | 0000000 | 000000 |
| 0.75-150 | 4-20 | 0-10V DC | 1/4 | 1/4 | 60 scfm @ 100 psi | 155 | 1 3/4" | 5 1/4" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
| 0.75-150 | 4-20 | 0-10V DC | 1/2 | 1/2 | 250 scfm @ 100 psi | 155 | 4 5/16" | 6 7/8" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
| 0.75-150 | 4-20 | 0-10V DC | 3/4 | 3/4 | 250 scfm @ 100 psi | 155 | 4 5/16" | 6 7/8" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 00000000 | 000000 | 0000000 | 00000 |
| 0.75-150 | 4-20 | 0-10V DC | 1 | 1 | 250 scfm @ 100 psi | 155 | 4 3/8" | 6 7/8" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 00000000 | 000000 | 0000000 | 00000 |

Regulators | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Connecting Cables | |||||||||||||
| Pressure Regulating Range, psi | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Wd. | Ht. | Housing Material | Max. Temp., °F | Electrical Connection Type | Environmental Rating | Specifications Met | Each | Each | ||
NPT Female Inlet and Outlet—LED Display | |||||||||||||||
±0.2% Regulating Accuracy | |||||||||||||||
| 0.75-150 | 1/8 | 1/8 | 51 scfm @ 100 psi | 155 | 1 3/4" | 5 1/4" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 0000000 | 0000000 | 0000000 | 000000 |
| 0.75-150 | 1/4 | 1/4 | 60 scfm @ 100 psi | 155 | 1 3/4" | 5 1/4" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
| 0.75-150 | 1/2 | 1/2 | 250 scfm @ 100 psi | 155 | 4 5/16" | 6 7/8" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
| 0.75-150 | 3/4 | 3/4 | 250 scfm @ 100 psi | 155 | 4 5/16" | 6 7/8" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
| 0.75-150 | 1 | 1 | 250 scfm @ 100 psi | 155 | 4 3/8" | 6 7/8" | Acetal Plastic | 120° | Plug | IEC Zone 2 Groups IIC, IIB, IIA, IP65 | ATEX II 3 G Ex nA IIC T5 Gc, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
Hazardous Location Electronically-Controlled
Precision Compressed Air Regulators

Intrinsically safe, these regulators cannot create sparks, so they’re safe to use in NEC Class I, II, and III, Division 1 and 2 hazardous locations. They translate electrical signals into steady output pressure for precise, repeatable motion. As the input signal increases, the output pressure increases proportionally within the regulating range. Pair them with sensors that produce the required input signal current or with programmable logic controllers (PLCs) for automatic setting adjustments. Install them in your air line after filters.
All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure.
BSPP threads are also known as G threads.
Pipe Size | Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pressure Regulating Range, psi | Input Signal Current, mA | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | No. of Gauge Ports | Wd. | Ht. | Housing Material | Max. Temp., °F | Includes | Environmental Rating | Specifications Met | Each | |
NPT Female Inlet and Outlet | ||||||||||||||||
±0.5% Regulating Accuracy | ||||||||||||||||
| 1-17 | 4-20 | 1/4 | 1/4 | 12 scfm @ 100 psi | 100 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 0000000 |
| 2-60 | 4-20 | 1/4 | 1/4 | 13.5 scfm @ 100 psi | 150 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 000000 |
| 3-9 | 4-20 | 1/4 | 1/4 | 12 scfm @ 100 psi | 100 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 000000 |
| 3-15 | 4-20 | 1/4 | 1/4 | 12 scfm @ 100 psi | 100 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 000000 |
| 3-27 | 4-20 | 1/4 | 1/4 | 12 scfm @ 100 psi | 100 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 000000 |
| 3-120 | 4-20 | 1/4 | 1/4 | 13.5 scfm @ 100 psi | 150 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 000000 |
| 6-30 | 4-20 | 1/4 | 1/4 | 12 scfm @ 100 psi | 100 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 000000 |
BSPP Female Inlet and Outlet | ||||||||||||||||
±0.5% Regulating Accuracy | ||||||||||||||||
| 3-15 | 4-20 | 1/4 | 1/4 | 12 scfm @ 100 psi | 100 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 000000 |
| 3-120 | 4-20 | 1/4 | 1/4 | 13.5 scfm @ 100 psi | 150 | No | 1 | 3" | 4 1/4" | Aluminum | 140° | Mounting Bracket | NEMA 4X; IP65; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | FM Approved | 00000000 | 000000 |
High-Flow Precision Compressed Air Regulators
Deliver a large volume of air at a steady pressure for precise, repeatable movement in cylinders, actuators, and automated systems. No matter how irregular your compressed air supply pressure is, these precision regulators have a flexible diaphragm that automatically adjusts to input pressure changes and an aspirator tube that creates a feedback loop to maintain set pressure within a tight band.
Relieving regulators exhaust when the downstream pressure exceeds the set pressure. Nonrelieving regulators don’t exhaust any downstream pressure—a helpful setup in highly controlled environments. To prevent pressure buildup, manually vent them or use a relief valve.
BSPP threads are also known as G threads.
Pressure gauges are for use with regulators with NPT threading.
Add mounting brackets to attach the regulator to a wall or your equipment.


Regulators | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Mounting Brackets | ||||||||||||
| Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | No. of Gauge Ports | Wd. | Ht. | Housing Material | Max. Temp., °F | Choose a Pressure Regulating Range, psi | Each | Each | ||
Relieving—NPT Female Inlet and Outlet | ||||||||||||||
±0.1% Regulating Accuracy | ||||||||||||||
| 1/4 | 1/4 | 100 scfm @ 100 psi | 250 | No | 2 | 4" | 7 5/8" | Aluminum | 200° | 00000000 | 0000000 | 00000000 | 000000 | |
| 1/2 | 1/2 | 225 scfm @ 100 psi | 250 | No | 2 | 4" | 7 5/8" | Aluminum | 200° | 00000000 | 000000 | 00000000 | 00000 | |
±0.05% Regulating Accuracy | ||||||||||||||
| 1/4 | 1/4 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 000000 | 000000 | 000000 | 0000 | |
| 3/8 | 3/8 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 000000 | 000000 | 000000 | 0000 | |
| 1/2 | 1/2 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 000000 | 000000 | 000000 | 0000 | |
Relieving—BSPP Female Inlet and Outlet | ||||||||||||||
±0.05% Regulating Accuracy | ||||||||||||||
| 1/4 | 1/4 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 00000000 | 000000 | 000000 | 0000 | |
| 3/8 | 3/8 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 00000000 | 000000 | 000000 | 0000 | |
| 1/2 | 1/2 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 00000000 | 000000 | 000000 | 0000 | |
Nonrelieving—NPT Female Inlet and Outlet | ||||||||||||||
±0.1% Regulating Accuracy | ||||||||||||||
| 1/2 | 1/2 | 225 scfm @ 100 psi | 250 | No | 2 | 4" | 7 5/8" | Aluminum | 200° | 0-100 | 00000000 | 000000 | 00000000 | 00000 |
| 3/4 | 3/4 | 250 scfm @ 100 psi | 250 | No | 2 | 4" | 7 5/8" | Aluminum | 200° | 00000000 | 000000 | 00000000 | 00000 | |
±0.05% Regulating Accuracy | ||||||||||||||
| 1/2 | 1/2 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 00000000 | 000000 | 000000 | 0000 | |
Nonrelieving—BSPP Female Inlet and Outlet | ||||||||||||||
±0.05% Regulating Accuracy | ||||||||||||||
| 1/4 | 1/4 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 00000000 | 000000 | 000000 | 0000 | |
| 1/2 | 1/2 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 6 1/8" | Aluminum | 160° | 00000000 | 000000 | 000000 | 0000 | |
Tamper-Resistant Precision Compressed Air Regulators

Prevent unintentional or unauthorized pressure changes in lines that demand constant, consistent air pressure. These regulators have a tamper-resistant cover that threads over the adjusting screw to block access. Use them to deliver steady air pressure in sensitive applications that rely on it for precise force and movement. All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure. Install them in your air line after filters.
BSPP threads are also known as G threads.
Regulators | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Mounting Brackets | ||||||||||||
| Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | No. of Gauge Ports | Wd. | Ht. | Housing Material | Max. Temp., °F | Choose a Pressure Regulating Range, psi | Each | Each | ||
NPT Female Inlet and Outlet | ||||||||||||||
±0.1% Regulating Accuracy | ||||||||||||||
| 1/4 | 1/4 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 7" | Aluminum | 160° | 0000000 | 0000000 | 000000 | 00000 | |
| 3/8 | 3/8 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 7" | Aluminum | 160° | 0000000 | 000000 | 000000 | 0000 | |
| 1/2 | 1/2 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 7" | Aluminum | 160° | 0000000 | 000000 | 000000 | 0000 | |
BSPP Female Inlet and Outlet | ||||||||||||||
±0.1% Regulating Accuracy | ||||||||||||||
| 1/4 | 1/4 | 80 scfm @ 100 psi | 250 | No | 2 | 3" | 7" | Aluminum | 160° | 0000000 | 000000 | 000000 | 0000 | |