McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    15 Products

    Air-Powered Constant-Flow-Rate Piston Pumps

    Image of Product. Front orientation. Piston Pumps. Air-Powered Constant-Flow-Rate Piston Pumps.
    Commonly called piston pumps, these are often used in high-pressure applications, such as hydrostatic testing of pipelines, tanks, and valves. Flow and outlet liquid pressure can be controlled by varying the air pressure. To calculate discharge liquid pressure, multiply the air pressure by the ratio shown in the table. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Flow
    Rate, gpm
    Air
    Pressure, psi
    Overall
    @ 0
    psi
    @ 3,000
    psi
    Max. ft. of
    Head, ft.
    Max. Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Consumption,
    scfm
    Air Connection
    (NPT)
    Intake Pipe
    Connection (NPT)
    Discharge Pipe
    Connection (NPT)
    Lg.
    Wd.
    Ht.
    Each
    86:1 Discharge Liquid to Inlet Air Pressure Ratio
    0.190.1728,76412,47010015145201/4 Female3/8 Female1/4 Female4 5/8"4"9"0000000000000000
     
    28:1 Discharge Liquid to Inlet Air Pressure Ratio
    0.580.139,3654,06010015145201/4 Female3/8 Female1/4 Female4 5/8"4"9"000000000000000
     
    11:1 Discharge Liquid to Inlet Air Pressure Ratio
    4.763,6791,59510015145451/2 Female1 Female1/2 Female10 3/4"7"12 1/4"000000000000000
     

    High-Pressure Constant-Flow-Rate Pumps without Motor for Pressure Washing

    Image of Product. Front orientation. Plunger Pumps. High-Pressure Constant-Flow-Rate Pumps without Motor for Pressure Washing.
    Also known as plunger pumps, these can provide pressures up to 3,000 psi. Use them for washdowns, drain jetting, and other pressurized water-spraying applications. Connect them directly to an electric motor to alter the pump speed. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Req. Power,
    hp
    For Motor Frame Size
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    For Shaft
    Dia.
    Each
    22,000-20 to 1602.7NEMA 56C3/8
    NPT
    Female3/8
    NPT
    Female8 1/4"8 5/8"6 1/2"5/8"000000000000000
    33,000-20 to 1406 1/5NEMA 182TC, NEMA 184TC1/2
    NPT
    Female3/8
    NPT
    Female9 1/2"9 1/4"7 1/8"1 1/8"00000000000000
    42,000-20 to 1405 1/2NEMA 182TC, NEMA 184TC1/2
    NPT
    Female3/8
    NPT
    Female9 1/2"9 1/4"7 1/8"1 1/8"00000000000000

    Lightweight Plastic Gasoline-Powered Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Lightweight Plastic Gasoline-Powered Dewatering Pumps.
    With a polypropylene housing, these pumps are about half the weight of other gasoline-powered pumps. Fill the fuel tank with gasoline to remove water at sites without power. Pumps are self-priming, which means that they create a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. They have a pull-start engine.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Cannot Be Sold to Canada—Pumps cannot be sold to Canada due to import regulations.
    Max. Flow Rate, gpm
    Intake
    Discharge
    Overall
    @ 20 Ft.
    of Head
    @ 50 Ft.
    of Head
    @ 70 Ft.
    of Head
    @ 90 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To, ft.
    Tank Cap.,
    qt.
    Temp. Range,
    ° F
    Power,
    hp
    Pipe
    Size
    Thread
    Type
    Connection
    Gender
    Pipe
    Size
    Thread
    Type
    Connection
    Gender
    Ht.
    Wd.
    Lg.
    Cannot Be
    Sold To
    Each
    13210684561157/16"202.2840 to 13052
    NPT
    ThreadedFemale2
    NPT
    ThreadedFemale19"16"13"Canada0000000000000
     
    Dewatering Pump Hose Kits

    Gasoline-Powered Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Gasoline-Powered Dewatering Pumps.
    Fill the fuel tank with gasoline to remove water at sites without power. These pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. They can be mounted up to 20 feet above your liquid source. All have a pull-start engine. Pumps are not submersible.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Cannot Be Sold To—Pumps cannot be sold to the regions listed due to import and engine regulations.
    Max. Flow Rate, gpm
    Intake
    Discharge
    Overall
    @ 20 Ft.
    of Head
    @ 50 Ft.
    of Head
    @ 70 Ft.
    of Head
    @ 90 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To, ft.
    Tank Cap.,
    qt.
    Temp. Range,
    ° F
    Power,
    hp
    Pipe
    Size
    Thread
    Type
    Connection
    Gender
    Pipe
    Size
    Thread
    Type
    Connection
    Gender
    Ht.
    Wd.
    Lg.
    Cannot Be
    Sold To
    Each
    2201801401001251"202.8432 to 18052
    NPT
    ThreadedFemale2
    NPT
    ThreadedFemale20"19 1/2"24"Canada000000000000000
    3402802201401103/4"205.540 to 18083
    NPT
    ThreadedFemale3
    NPT
    ThreadedMale23 1/2"22 1/2"31"Canada0000000000000000
     
    Accessories for Dewatering Pumps

    Mobile Gasoline-Powered Sewage Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Mobile Gasoline-Powered Sewage Dewatering Pumps.
    Wheel these pumps to remote areas with no power. They can handle sewage water with thick sludge, silt, and debris up to 2" in diameter. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. All have a pull-start engine. They are not submersible.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    1.6 gal. Tank—Pumps with a tank capacity of 1.6 gallons includes an electric starter that operates on a 12-volt battery (sold separately).
    Cannot Be Sold to Canada—These pumps cannot be sold to Canada due to import regulations.
    Max. Flow Rate, gpm
    Intake
    Discharge
    Overall
    @ 30 Ft.
    of Head
    @ 60 Ft.
    of Head
    @ 90 Ft.
    of Head
    @ 100 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Thread
    Type
    Pipe
    Size
    Gender
    Thread
    Type
    Pipe
    Size
    Gender
    Ht.
    Wd.
    Lg.
    Cannot Be
    Sold To
    Each
    1.6 gal. Tank
    530335110201032"2040 to 18013NPT
    4
    FemaleNPT
    4
    Female31"38"45"Canada00000000000000000
     
    1.7 gal. Tank
    460275751002"2040 to 18013NPT
    4
    MaleNPT
    4
    Male37"38"45"Canada0000000000000000
     

    Corrosion-Resistant Gasoline-Powered Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Corrosion-Resistant Gasoline-Powered Dewatering Pumps.
    Built with high-chromium stainless steel components, this pump stands up to salt water with up to 25% sand by volume and resists wear caused by abrasive particles. Fill the fuel tank with gasoline to remove water at sites without power. Pump is self-priming, which means it creates a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. Pump has a pull-start engine. It is not submersible.
    Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
    Cannot Be Sold to Canada—This pump cannot be sold to Canada due to import regulations.
    Max. Flow Rate, gpm
    Intake
    Discharge
    Overall
    @ 20 Ft.
    of Head
    @ 50 Ft.
    of Head
    @ 70 Ft.
    of Head
    @ 90 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To, ft.
    Tank Cap.,
    qt.
    Temp. Range,
    ° F
    Power,
    hp
    Pipe
    Size
    Thread
    Type
    Connection
    Gender
    Pipe
    Size
    Thread
    Type
    Connection
    Gender
    Ht.
    Wd.
    Lg.
    Cannot Be
    Sold To
    Each
    1531259358981/2"103.840 to 16052
    NPT
    ThreadedFemale2
    NPT
    ThreadedFemale20"20"25"Canada0000000000000000
     
    Accessories for Dewatering Pumps
    back to top