About Gas Regulators
More
High-Purity Tank-Mount Pressure-Regulating Valves for Inert Gas
- For Use With: See Table
- Temperature Range: -20° to 120° F
Reduce contaminants in research sample systems, emission monitoring systems, chromatography, and other high-purity applications that use argon, helium, nitrogen, or carbon dioxide. These valves have a 316 stainless steel and brass body with a smooth finish to reduce dust collection and internal components designed to protect the seal and diaphragm from contamination. They automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
Chrome-plated valves add a layer of corrosion resistance.


Inlet | Outlet | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Pressure Adjustment Method | Each | |
Swagelok® Female Outlet × NGO Male Inlet | ||||||||||
Brass Body—316 Stainless Steel Diaphragm and PTFE Seal | ||||||||||
CGA 580 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 15 | Knob | 0000000 | 0000000 |
CGA 580 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 125 | Knob | 0000000 | 000000 |
CGA 580 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 500 | Knob | 0000000 | 000000 |
CGA 580 | Side | Right Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 15 | Knob | 0000000 | 000000 |
CGA 580 | Side | Right Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 50 | Knob | 0000000 | 000000 |
CGA 580 | Side | Right Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 125 | Knob | 0000000 | 000000 |
Chrome-Plated Brass Body—316 Stainless Steel Diaphragm and PTFE Seal | ||||||||||
CGA 580 | Side | Right Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 50 | Knob | 0000000 | 000000 |


Inlet | Outlet | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Pressure Adjustment Method | Each | |
Swagelok® Female Outlet × NGO Female Inlet | ||||||||||
Brass Body—316 Stainless Steel Diaphragm and PTFE Seal | ||||||||||
CGA 320 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 125 | Knob | 0000000 | 0000000 |
CGA 320 | Side | Right Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 125 | Knob | 0000000 | 000000 |
Chrome-Plated Brass Body—316 Stainless Steel Diaphragm and PTFE Seal | ||||||||||
CGA 320 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 15 | Knob | 0000000 | 000000 |
CGA 320 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 50 | Knob | 0000000 | 000000 |
CGA 320 | Side | Right Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 15 | Knob | 0000000 | 000000 |
CGA 320 | Side | Right Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 50 | Knob | 0000000 | 000000 |
CGA 320 | Side | Right Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 125 | Knob | 0000000 | 000000 |
Cleaned and Bagged Panel-Mount
Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Nitrogen, Argon, Helium
- Temperature Range: -40° to 165° F
Commonly used for oxygen service and other high-purity applications, these valves come cleaned and bagged to prevent contamination. All automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have threads below the adjustment knob and come with a panel-mount nut. They can also be surface mounted. All have two gauge ports. Body is 316 stainless steel for exceptional corrosion resistance. Valves are no-bleed style, so they keep process gases contained in the valve.
For technical drawings and 3-D models, click on a part number.
Inlet | Outlet | Gauge Port | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pressure Range, psi | Pipe Size | Connection | End-to-End Lg. | Panel Cutout Dia. | Each | |
NPT Female | |||||||||||
316 Stainless Steel Body—316 Stainless Steel Diaphragm and PTFE Seal | |||||||||||
1/4 | Side | 3,500 | 1/4 | Side | 0 to 25 | 1/4 | NPT Female | 5 3/8" | 1.37" | 0000000 | 0000000 |
1/4 | Side | 3,500 | 1/4 | Side | 0 to 100 | 1/4 | NPT Female | 5 3/8" | 1.37" | 0000000 | 000000 |
1/4 | Side | 3,500 | 1/4 | Side | 0 to 250 | 1/4 | NPT Female | 5 3/8" | 1.37" | 0000000 | 000000 |
1/4 | Side | 3,500 | 1/4 | Side | 0 to 500 | 1/4 | NPT Female | 5 3/8" | 1.37" | 0000000 | 000000 |
Cleaned and Bagged Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Nitrogen, Oxygen, Argon, Helium, Neon
- Temperature Range: -40° to 165° F
Often used for oxygen service and other high-purity applications, these valves are cleaned and bagged to meet CGA G-4.1 standards to prevent contamination. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have two gauge ports. They are no-bleed style, so they keep process gases contained in the valve.
For technical drawings and 3-D models, click on a part number.
Inlet | Outlet | Gauge Port | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Choose an Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||
Brass Body—Buna-N Diaphragm and Fluoroelastomer Seal | ||||||||||
1/2 | Side | 500 | 1/2 | Side | 1/4 | Side | 2 13/16" | 00000000 | 0000000 | |
3/4 | Side | 500 | 3/4 | Side | 1/4 | Side | 3 5/16" | 00000000 | 000000 | |
1 | Side | 500 | 1 | Side | 1/4 | Side | 3 5/16" | 00000000 | 000000 |
High-Purity Tank-Mount Pressure-Regulating Valves for Fuel Gases


- For Use With: Hydrogen, Methane
- Temperature Range: -20° to 120° F
Designed to reduce contaminants in high-purity applications using hydrogen and methane gas, these valves have a stainless steel and brass body with a smooth finish to reduce dust collection and internal components designed to protect the seal and diaphragm from contamination. They’re often used in research sample systems, emission monitoring systems, and chromatography. Valves automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves come with a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
Inlet | Outlet | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Pressure Adjustment Method | Each | |
Swagelok® Female Outlet × NGO Female Inlet | ||||||||||
Brass/Stainless Steel Body—316 Stainless Steel Diaphragm and PTFE Seal with Relief Valve | ||||||||||
CGA 350 | Side | Left Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 15 | Knob | 0000000 | 0000000 |
CGA 350 | Side | Left Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 125 | Knob | 0000000 | 000000 |
CGA 350 | Side | Left Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 15 | Knob | 0000000 | 000000 |
CGA 350 | Side | Left Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 125 | Knob | 0000000 | 000000 |
CGA 350 | Side | Left Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 500 | Knob | 0000000 | 000000 |
Pressure-Regulating Valves for Cryogenic Liquids

- For Use With: Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen
- Temperature Range: -320° to 150° F
These valves can withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range.
For technical drawings and 3-D models, click on a part number.