    15 Products

    Square D Load-Center Circuit Breakers

    Match these circuit breakers to Square D breaker boxes or panel boards of the same manufacturer series. Because they are thermal-magnetic, these breakers trip two different ways. They either trip when heat is generated by sustained low-level overload current or quickly when the magnetic coil senses a high-current short circuit.
    Homeline Series
    Image of Product. Homeline Series, 1 Pole. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 1 Pole—Toggle-Switch Style.
    Image of Product. Homeline Series, 2 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 1 Pole with Tandem Circuit—Toggle Switch.
    Image of Product. Homeline Series, 3 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 2 Poles—Toggle Switch.

    Homeline

    Series, 1

    Pole

    Homeline

    Series, 2

    Poles

    Homeline

    Series, 3

    Poles

    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
    15120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K71000000
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K7200000
    30120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K7300000
    40120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K9100000
    50 120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K10100000
     
    1 Pole with Tandem Circuit—Toggle Switch
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K8400000
     
    2 Poles—Toggle Switch
    15120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K9200000
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K7500000
    30120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K7600000
    40120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K7700000
    50 120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K10200000
    60120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K10300000
     
    Homeline Series with 6 mA Ground Fault Sensitivity
    Image of Product. Homeline Series, 1 Pole. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 1 Pole—Toggle-Switch Style.
    Image of Product. Homeline Series, 3 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 2 Poles—Toggle Switch.

    Homeline

    Series, 1

    Pole

    Homeline

    Series, 3

    Poles

    Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6 mA. This minimizes the risk of electric shock to workers and equipment.
    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
    2012050/6010,000 amp @ 120V ACBreaker BoxSnap On1"UL 489UL Listed
    69225K820000000
     
    2 Poles—Toggle Switch
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K104000000
    30120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K105000000
     