How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
Metal Garden Hose Fittings
Connect these fittings to rubber or plastic garden hose for a variety of water supply applications.
Zinc fittings have good corrosion resistance. Fittings with a barbed end are also known as hose menders and splicers. Use them to connect lengths of hose or to repair damaged hose. Fittings with a fasten-on barbed end provide a more secure hold than clamp-on fittings and fittings with gripping tabs; slide the hose over the internal barb and tighten the clamp around the hose with the included screws.
For technical drawings and 3-D models, click on a part number.

For Hose ID | Garden Hose Trade Size | Lg. | Pkg. Qty. | Pkg. | |
Zinc | |||||
---|---|---|---|---|---|
5/8" to 3/4" | 3/4 | 2" | 1 | 0000000 | 00000 |

For Hose ID | Garden Hose Trade Size | Washer Material | Lg. | Pkg. Qty. | Pkg. | |
Zinc | ||||||
---|---|---|---|---|---|---|
5/8" to 3/4" | 3/4 | TPR Rubber | 2" | 1 | 0000000 | 00000 |

For Hose ID | Lg. | Pkg. Qty. | Pkg. | |
Zinc | ||||
---|---|---|---|---|
5/8" to 3/4" | 2 1/8" | 1 | 0000000 | 000000 |

Mounting | |||||||
---|---|---|---|---|---|---|---|
Garden Hose Trade Size | Washer Material | Lg. | Chain Lg. | Fasteners Included | Hole Dia. | Each | |
Zinc | |||||||
3/4 | CPVC Plastic | 4 13/32" | 12" | No | 1/4" | 00000000 | 00000 |
Wye-Shaped On/Off Valves with Garden Hose Threads



Convert one faucet into two, four, or five convenient outlets. Each outlet has individually operated shutoff valves.
Zinc valves have good corrosion resistance. Some also have a TPR rubber or plastic coating to protect your hands—the coating keeps valves from getting hot in the sun or cold in the winter.
Valves with flexible outlets are easy to install and help keep your hose from kinking.
For technical drawings and 3-D models, click on a part number.
No. of Outlets | Max. Pressure | Temp. Range, °F | Includes | Each | |
Zinc | |||||
---|---|---|---|---|---|
2 | 60 psi @ 100° F | 35° to 100° | Washers | 0000000 | 00000 |
4 | 60 psi @ 100° F | 35° to 100° | Washers | 0000000 | 00000 |
Zinc with TPR Rubber Coating | |||||
2 | 60 psi @ 100° F | 35° to 100° | Washers | 0000000 | 00000 |
2 | 60 psi @ 100° F | 35° to 100° | Washers, Flexible Hose Outlets | 0000000 | 00000 |
4 | 60 psi @ 100° F | 35° to 100° | Washers, Support Brace | 0000000 | 00000 |
Zinc with Plastic Coating | |||||
5 | 60 psi @ 100° F | 35° to 100° | Washers, Support Brace, Mounting Hardware | 0000000 | 00000 |
On/Off Valves with Garden Hose Threads

Save trips to the faucet to shut off the water by attaching these fittings to the end of your garden hose.
Zinc valve is for use with cold water only.
For technical drawings and 3-D models, click on a part number.
Material | Max. Pressure | Temp. Range, °F | Includes | Each | |
Zinc | 120 psi @ 60° F | Not Rated | Washers | 0000000 | 00000 |
Air Nozzles




These nozzles are engineered for the most efficient air consumption. Volume (dBA) is measured 3 ft. from the nozzle at 80 psi.
Nozzles that meet OSHA 29 CFR 1910.242 conform to requirements for maximum air outlet pressure. Nozzles that meet OSHA 29 CFR 1910.95 conform to requirements for noise.
For technical drawings and 3-D models, click on a part number.


Air Inlet Pipe Size | Air Consumption | Max. Temp., °F | Volume, dBA | Tip OD | O'all Lg. | Max. Inlet Pressure, psi | Material | Specifications Met | Each | ||
C | 1/8 | 15 cfm @ 100 psi | 158° | Not Rated | 5/16" | 2 3/16" | 145 | Zinc | OSHA Compliant 29 CFR 1910.242 | 00000000 | 000000 |
D | 1/2 | 73 cfm @ 100 psi | 250° | 87 | 1" | 2 3/4" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 000000 |
D | 3/4 | 110 cfm @ 100 psi | 250° | 96 | 1 1/4" | 3 1/2" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 000000 |


Air Inlet Pipe Size | Air Consumption | Max. Temp., °F | Volume, dBA | Tip OD | O'all Lg. | Max. Inlet Pressure, psi | Material | Specifications Met | Each | ||
D | 1/8 | 12 cfm @ 100 psi | 250° | 71 | 1/2" | 1 3/16" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 000000 |
D | 3/8 | 44 cfm @ 100 psi | 250° | 82 | 3/4" | 1 5/8" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 000000 |
D | 1/2 | 73 cfm @ 100 psi | 250° | 87 | 1" | 2" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 000000 |
D | 3/4 | 110 cfm @ 100 psi | 250° | 96 | 1 1/4" | 2 1/2" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 000000 |
E | 1/4 | 18 cfm @ 100 psi | 250° | 74 | 3/4" | 1 3/4" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 00000 |
Wide-Airflow Air Nozzles




The flat nozzle tip distributes air over a wider area than focused-airflow nozzles. Volume (dBA) is measured 3 ft. from the nozzle at 80 psi.
Nozzles that are OSHA Compliant 29 CFR 1910.242 conform to requirements for maximum air outlet pressure. Nozzles that are OSHA Compliant 29 CFR 1910.95 conform to requirements for noise.
For technical drawings and 3-D models, click on a part number.


Tip | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet Pipe Size | Air Consumption | Max. Temp., °F | Volume, dBA | Wd. | Thick. | O'all Lg. | Max. Inlet Pressure, psi | Material | Specifications Met | Each | ||
A | 1/8 | 13 cfm @ 100 psi | 158° | Not Rated | 15/16" | 1/8" | 2 3/16" | 145 | Zinc | OSHA Compliant 29 CFR 1910.242 | 00000000 | 000000 |
A | 1/4 | 25 cfm @ 100 psi | 158° | Not Rated | 1 7/8" | 1/8" | 3 1/8" | 145 | Zinc | OSHA Compliant 29 CFR 1910.242 | 00000000 | 00000 |
K | 1/8 | 15 cfm @ 100 psi | 155° | 84 | 15/16" | 3/16" | 15/16" | 145 | Zinc | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |



Tip | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet Pipe Size | Air Consumption | Max. Temp., °F | Volume, dBA | Wd. | Thick. | O'all Lg. | Max. Inlet Pressure, psi | Material | Specifications Met | Each | ||
A | 1/8 | 25 cfm @ 100 psi | 158° | 85 | 1 13/16" | 3/16" | 3 1/8" | 145 | Zinc | OSHA Compliant 29 CFR 1910.242 | 00000000 | 000000 |
E | 1/4 | 26 cfm @ 100 psi | 250° | 75 | 2" | 7/16" | 2 1/16" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 000000 |
E | 1/4 | 37 cfm @ 80 psi | 250° | 83 | 2" | 7/16" | 2 1/16" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 0000000 | 000000 |
N | 1/8 | 11 cfm @ 80 psi | 250° | 75 | 1" | 3/8" | 1 5/16" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 0000000 | 00000 |
N | 1/8 | 18 cfm @ 80 psi | 250° | 82 | 1" | 3/8" | 1 5/16" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 0000000 | 00000 |


Tip | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet Pipe Size | Air Consumption | Max. Temp., °F | Volume, dBA | Wd. | Thick. | O'all Lg. | Max. Inlet Pressure, psi | Material | Specifications Met | Each | ||
A | 1/8 | 12 cfm @ 85 psi | 155° | 82 | 15/16" | 3/16" | 2 3/16" | 145 | Zinc | OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000 |
A | 1/4 | 22 cfm @ 85 psi | 155° | 85 | 1 13/16" | 3/16" | 3 1/8" | 145 | Zinc | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |
K | 1/8 | 13 cfm @ 85 psi | 155° | 84 | 15/16" | 3/16" | 15/16" | 145 | Zinc | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |


Tip | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet Pipe Size | Air Consumption | Max. Temp., °F | Volume, dBA | Wd. | Thick. | O'all Lg. | Max. Inlet Pressure, psi | Material | Specifications Met | Each | ||
E | 1/4 | 37 cfm @ 80 psi | 250° | 83 | 2" | 7/16" | 2 1/16" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 0000000 | 0000000 |
N | 1/8 | 18 cfm @ 80 psi | 250° | 82 | 1" | 3/8" | 1 5/16" | 250 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 0000000 | 00000 |
Magnet-Mount Bend-and-Stay Air Nozzles

The magnetic base with an attached flexible hose mounts to your work surface. Bend the hose to position the nozzle and keep it in place. Use the control valve on the base to adjust airflow.
Zinc nozzle meets OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure and OSHA 29 CFR 1910.95 requirements for noise.
Air Inlet | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Hoses | Pipe Size | Thread Type | Gender | Air Consumption | Max. Temp., °F | Volume | Tip OD | O'all Lg. | Max. Magnetic Pull, lbs. | Max. Inlet Pressure, psi | Material | Specifications Met | Each | |
Zinc Nozzle | ||||||||||||||
1 | 1/4 | NPT | Female | 16 cfm @ 100 psi | 140 | 74 dBA @ 80 psi | 3/4" | 15 11/16" | 100 | 150 | Zinc | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 0000000 |
Wide-Airflow Bend-and-Stay Air Nozzles

The flat shape distributes air over a wider area than focused-airflow nozzles. These nozzles are attached to a flexible hose that bends and holds its shape until you reposition it. All conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure and OSHA 29 CFR 1910.95 requirements for noise.
For technical drawings and 3-D models, click on a part number.
Air Inlet | Tip | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Air Consumption | Max. Temp., °F | Volume | Wd. | Thick. | O'all Lg. | Max. Inlet Pressure, psi | Hose Material | Specifications Met | Each | |
Zinc | |||||||||||||
1/4 | NPT | Male | 12 cfm @ 100 psi | 140° | 75 dBA @ 80 psi | 1" | 3/8" | 25" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 0000000 |
1/4 | NPT | Male | 14 cfm @ 100 psi | 140° | 75 dBA @ 80 psi | 1" | 3/8" | 13 11/16" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 00000000 | 000000 |
1/4 | NPT | Male | 21 cfm @ 100 psi | 140° | 85 dBA @ 80 psi | 1" | 3/8" | 25" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |
1/4 | NPT | Male | 26 cfm @ 100 psi | 140° | 80 dBA @ 80 psi | 2" | 3/8" | 7 3/4" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |
1/4 | NPT | Male | 26 cfm @ 100 psi | 140° | 80 dBA @ 80 psi | 2" | 3/8" | 13 3/4" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |
1/4 | NPT | Male | 26 cfm @ 100 psi | 140° | 80 dBA @ 80 psi | 2" | 3/8" | 19 3/4" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |
1/4 | NPT | Male | 26 cfm @ 100 psi | 140° | 80 dBA @ 80 psi | 2" | 3/8" | 25 3/4" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |
1/4 | NPT | Male | 45 cfm @ 100 psi | 140° | 85 dBA @ 80 psi | 2" | 1/2" | 7 3/4" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |
1/4 | NPT | Male | 45 cfm @ 100 psi | 140° | 85 dBA @ 80 psi | 2" | 1/2" | 13 3/4" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |
1/4 | NPT | Male | 45 cfm @ 100 psi | 140° | 85 dBA @ 80 psi | 2" | 1/2" | 19 3/4" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |
1/4 | NPT | Male | 45 cfm @ 100 psi | 140° | 85 dBA @ 80 psi | 2" | 1/2" | 37 3/4" | 250 | PVC Plastic | OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 000000000 | 000000 |