About Sleeving
More
About Plastic and Rubber Tubing
More
About Conduit
More
High-Pressure Hard Plastic Tubing for Air and Water
Excellent strength and durability allow this tubing to handle high-pressure air and water applications.
Nylon tubing can handle higher pressures than polycarbonate tubing. It won’t crack even at low temperatures. Tubing is semi-flexible, so it is good for gradual bends. Semi-clear tubing gives you a limited view inside the line. Opaque tubing doesn’t allow you to see what’s flowing through the line.
For technical drawings and 3-D models, click on a part number.

- Semi-Flexible
- Compatible with Compression Fittings, Push to Connect Tube Fittings or both; see For Connection Style
- See table for hardness
- Temperature Range: See table

- Semi-Flexible
- Compatible with Compression Tube Fittings
- See table for hardness
- Temperature Range: See table
Electrical-Insulating Tube Sleeving

Add a layer of insulation to prevent electricity and heat from dissipating from wire and cable. This sleeving is often used in motors, transformers, and generators. Made of coated fiberglass, it resists abrasion, acids, alkalies, and chemicals.
Acrylic-coated sleeving is more flexible than vinyl-coated sleeving, so it bends around tight corners. It resists solvents and oil.
Chemical-Resistant Tube Sleeving

Made of PVC, this sleeving resists chemicals, oil, and acids. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Because this sleeving is non-expandable, it does not stretch, so it’s best for applications where you know the exact diameter of the items you need to protect.
Flexible Metal Conduit
For technical drawings and 3-D models, click on a part number.


Also known as FMC, this conduit offers the crush resistance of metal combined with flexibility to handle bends in tight spaces.
Zinc-plated steel conduit has a heavy zinc coating for corrosion resistance. Aluminum conduit is lighter than steel and has good corrosion resistance. It's often used to hook up motors and light fixtures.



× Threaded—
With Two Screws


Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-clamp end tightens around conduit with a screw. The twist-in end attaches to conduit with a few quick turns.
Conduit Connection | Electrical Box Connection | |||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | For Knockout Trade Size | Gender | Includes | Each | |
Twist-In Conduit Connection × Threaded Electrical Box Connection | ||||||||
3/8 | Male | 1/2 | NPSM | __ | Male | Locknut | 0000000 | 00000 |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | ||||||||
3/8 | Female | 1/2 | NPSM | __ | Male | Locknut | 0000000 | 0000 |
3/8 | Female | 1/2 | NPSM | __ | Male | Locknut, Two Screws | 0000000 | 0000 |
Screw-Clamp Conduit Connection × Snap-In Electrical Box Connection | ||||||||
3/8 | Female | __ | __ | 1/2 | Male | __ | 0000000 | 0000 |
Push-In Conduit Connection × Snap-In Electrical Box Connection | ||||||||
3/8 | Female | __ | __ | 1/2 | Male | __ | 0000000 | 0000 |

Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-clamp end tightens around conduit with a screw.
Iron adapters are stronger and more durable than zinc adapters.
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Includes | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Female | 1/2 | NPSM | Male | Locknut | 0000000 | 00000 |

Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-on end screws onto the OD of conduit.
Conduit Connection | Electrical Box Connection | |||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Includes | Specifications Met | Each | |
Screw-On Conduit Connection × Threaded Electrical Box Connection | ||||||||
3/8 | Female | 1/2 | NPSM | Male | Locknut | UL Listed, C-UL Listed | 0000000 | 00000 |


Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-clamp end tightens around conduit with a screw. The twist-in end attaches to conduit with a few quick turns.
316 stainless steel adapters are the most corrosion resistant.
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Includes | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Female | 1/2 | NPSM | Male | Locknut | 0000000 | 000000 |
Twist-In Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Male | 1/2 | NPSM | Male | Locknut | 0000000 | 00000 |

Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-clamp end tightens around conduit with a screw.

Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-clamp end tightens around conduit with a screw.
Iron adapters are stronger and more durable than zinc adapters.
Conduit Connection | Electrical Box Connection | |||||
---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | ||||||
3/8 | Female | 1/2 | NPSM | Male | 0000000 | 00000 |

Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-clamp end tightens around conduit with a screw.
316 stainless steel adapters are the most corrosion resistant.
Conduit Connection | Electrical Box Connection | |||||
---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | ||||||
3/8 | Female | 1/2 | NPSM | Male | 0000000 | 000000 |



Attach flexible metal conduit and types AC and MC armored cable to a knockout in an outlet box or enclosure. Wye adapters join two pieces of conduit or armored cable to one knockout. The snap-in end has tabs that snap into the knockout without locknuts or tools.
The screw-clamp end tightens around conduit with a screw.
Conduit Connection | Electrical Box Connection | |||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | For Knockout Trade Size | Gender | Includes | Each | |
Push-In Conduit Connection × Snap-In Electrical Box Connection | ||||||||
3/8 | Female | __ | __ | 1/2 | Male | __ | 0000000 | 00000 |
Screw-Clamp Conduit Connection × Snap-In Electrical Box Connection | ||||||||
3/8 | Female | __ | __ | 1/2 | Male | __ | 0000000 | 0000 |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | ||||||||
3/8 | Female | 1/2 | NPSM | __ | Male | Locknut | 0000000 | 0000 |

Also known as antishort bushings, these grommets slide into the ends of conduit and types AC and MC armored cable to protect wire and cable from sharp edges.
Conduit Connection | |||||
---|---|---|---|---|---|
Conduit Trade Size | Gender | Color | Pkg. Qty. | Pkg. | |
3/8 | Female | Red | 100 | 0000000 | 000000 |
Continuous-Flex Plastic Conduit
For technical drawings and 3-D models, click on a part number.


In addition to continuous-motion applications such as robotics, this conduit is suitable for high-vibration applications. Also known as mechanical protection tubing (MPT), it resists solvents, fuels, hydraulic and lubricating oils, and UV light.

Tabs on one end snap into grooves in continuous-flex plastic conduit; the other end attaches to a knockout in an outlet box or enclosure. These fittings resist solvents, fuels, hydraulic and lubricating oils, and UV light. Fittings meet IP66 for protection from dust and water jets.
Conduit Connection | Electrical Box Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Conduit OD | Gender | OD | Thread Size | Gender | Material | Color | Temperature Range, °F | Environment | Environmental Rating | Specifications Met | Each | |
Snap-In Conduit Connection × PG Threaded Electrical Box Connection | ||||||||||||
0.51" | Female | 0.91" | PG-11 | Male | Nylon | Black | -40° to 220° | Washdown | IP66 | UL Recognized Component | 00000000 | 00000 |

Tabs on one end snap into grooves in continuous-flex plastic conduit; the other end attaches to a knockout in an outlet box or enclosure. These fittings resist solvents, fuels, hydraulic and lubricating oils, and UV light. Fittings meet IP66 for protection from dust and water jets.
Conduit Connection | Electrical Box Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Conduit OD | Gender | OD | Thread Size | Gender | Material | Color | Temperature Range, °F | Environment | Environmental Rating | Specifications Met | Each | |
Snap-In Conduit Connection × PG Threaded Electrical Box Connection | ||||||||||||
0.51" | Female | 0.91" | PG-11 | Male | Nylon | Black | -40° to 220° | Washdown | IP66 | UL Recognized Component, CSA Certified, CE Marked | 00000000 | 000000 |