McMaster-Carr logo
    Filter by
    Conduit Trade Size
    Industrial Info Snippet
    System of Measurement
    Fitting Type
    ID
    Attribute Image
    Conduit Texture
    Maximum Temperature
    Bend Radius
    Attribute Image
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Cover Material
    Industrial Info Compare
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    22 Products
    About Conduit
    industrial info icon

    Compare rigid and flexible conduit materials and identify the trade size for compatible fittings.

    Liquid-Tight Flexible Metal (LFMC) Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Liquid-Tight Flexible Metal (LFMC) Conduit and Fittings.
    Seal out moisture with conduit that also prevents crushing in tight spaces. The corrugated metal core bends around obstacles without damaging cables, and the protective cover keeps water out. Use with compatible fittings for a liquid-tight seal in wet indoor, outdoor, and underground locations.
    Conduit
    Image of Product. Front orientation. Conduit and Fittings. Liquid-Tight Flexible Metal (LFMC) Conduit and Fittings, Conduit .
    Run wiring through conduit to route and protect it.
    Ultra Flexible—Bend and twist to fit through tighter spaces than flexible conduit.
    PVC Cover—Shields wiring from moisture and chemical exposure. PVC won't corrode, but it's less chemical resistant than silicone rubber.
    TPE Cover—Lightweight protection from moisture, corrosion, and temperature fluctuations. TPE does not offer the chemical resistance of PVC or silicone rubber covers.
    Silicone Rubber Cover—Protects from moisture, chemicals, corrosion, and temperature fluctuations.
    Per Ft.
    Conduit
    Trade Size
    Bend
    Radius
    Material
    Temp.,
    ° F
    Includes
    Specs. Met
    Choose a Length, ft.
    Choose a
    Color
    1-99
    100-Up
    Flexible
     
    PVC Cover
    1/2
    3"Zinc-Plated Steel-20 to 175Copper Ground WireCSA Certified, UL Listed2, 5, 10, 25, 50, 100Gray8071K420000000000
    1/2
    3"Zinc-Plated Steel0 to 1405, 10, 25, 50, 100Gray74525K8100000000
    1/2
    3"Zinc-Plated Steel0 to 140NSF/ANSI 169
    5, 10, 25, 50, 100White8235K5800000000
    1/2
    4"Zinc-Plated Steel-50 to 220Copper Ground WireUL Listed
    2, 5, 10, 25, 50, 100Gray8068K3200000000
    1/2
    4"Zinc-Plated Steel0 to 140Copper Ground WireCSA Certified, UL Listed5, 10, 25, 50, 100, 200Gray, Blue7127K200000000
     
    TPE Cover
    1/2
    3"Zinc-Plated Steel-75 to 3002, 5, 10, 25, 50, 100Black8235K5200000000
     
    Silicone Rubber Cover
    1/2
    4"Zinc-Plated Steel-90 to 390Copper Ground Wire2, 5, 10, 25, 50, 100Gray8235K650000000000
     
    Ultra Flexible
     
    PVC Cover
    1/2
    2"Zinc-Plated Steel0 to 1405, 10, 25, 50, 100Black8069K1200000000
     

    Flexible Metal (FMC) Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings.
    Make tight bends and protect wiring from being crushed. This corrugated conduit snakes around corners where rigid metal conduit won’t fit. For use indoors, it’s ideal for short connections or runs through walls in spaces that require both flexibility and durability.
    Conduit
    Image of Product. Front orientation. Conduit and Fittings. Flexible Metal (FMC) Conduit and Fittings, Conduit .
    Run wiring through conduit to route and protect it.
    Bend and Stay—Flex this conduit and it stays routed in position. It is not designed for repeated bending, which can weaken the construction.
    Galvanized Steel—Strong and resists rust and mild chemicals.
    Zinc-Plated Steel—The strength of steel with a plating that protects from occasional exposure to moisture.
    304 Stainless Steel—The choice for wet and outdoor environments.
    Aluminum—One-third the weight of steel that's the same size. Aluminum is also nonmagnetic to prevent electrical interference in nearby equipment.
    Per Ft.
    Conduit
    Trade Size
    Bend
    Radius
    Specs.
    Met
    Choose a Length, ft.
    1-99
    100-Up
    Flexible
     
    Zinc-Plated Steel
    1/2
    3"UL Listed
    10, 25, 50, 10074115K30000000000
     
    304 Stainless Steel
    1/2
    2"5, 10, 253994K1200000000
     
    Aluminum
    1/2
    3"UL Listed
    10, 25, 50, 10073145K300000000
     
    Bend and Stay
     
    Galvanized Steel
    1/2
    3"5, 10, 25, 50, 10074115K9200000000
     

    Liquid-Tight Flexible Plastic (LFNC-A) Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Liquid-Tight Flexible Plastic (LFNC-A) Conduit and Fittings.
    Keep out moisture and protect wiring against strain from constant stretching and vibration. Made of reinforced PVC that resists chemicals, this conduit is often used in robotics and other continuous-motion applications. Pair with compatible fittings for a liquid-tight seal indoors, outdoors, or underground.
    Conduit
    Image of Product. Front orientation. Conduit and Fittings. Liquid-Tight Flexible Plastic (LFNC-A) Conduit and Fittings, Conduit .
    Run wiring through conduit to route and protect it.
    Per Ft.
    Conduit
    Trade Size
    Bend
    Radius
    Color
    Temp.,
    ° F
    Specs. Met
    Choose a Length, ft.
    1-99
    100-Up
    PVC
    1/2
    3"Orange0 to 140CSA Certified, UL Listed2, 5, 10, 25, 50, 1008465K2200000000000
     

    Liquid-Tight Flexible Plastic (LFNC-B) Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Liquid-Tight Flexible Plastic (LFNC-B) Conduit and Fittings.
    Block out moisture and protect wiring abrasion and crushing. This conduit has a tougher construction than LFNC-A, but it’s less resistant to vibration. For use indoors or outdoors, components are made of PVC or nylon to resist chemicals and environmental exposure. Conduit can also be buried or encased in concrete. Pair it with compatible fittings for a liquid-tight seal.
    Conduit
    Image of Product. Front orientation. Conduit and Fittings. Liquid-Tight Flexible Plastic (LFNC-B) Conduit and Fittings, Conduit .
    Run wiring through conduit to route and protect it.
    Per Ft.
    Conduit
    Trade Size
    Bend
    Radius
    Color
    Temp.,
    ° F
    Specs. Met
    Choose a Length, ft.
    1-99
    100-Up
    PVC
    1/2
    4"Gray0 to 165CSA Certified, UL Listed5, 10, 25, 50, 1007581K420000000000
     

    Chemical-Resistant Tube Wire Sleeving

    Image of Product. Front orientation. Wire Sleeving. Chemical-Resistant Tube Wire Sleeving.
    Made of PVC, this sleeving resists chemicals, oil, and acids. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Because this sleeving is non-expandable, it does not stretch, so it’s best for applications where you know the exact diameter of the items you need to protect.
    Per Ft.
    ID
    For Wire
    Dia.
    Wall
    Thk.
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    Color
    Choose a Length, ft.
    1-99
    100-Up
    PVC
    0.63"5/8"0.03"0 to 220UL Listed
    UL 2556 VW-1
    Black10, 25, 50, 1001508T350000000000
     

    Flexible Plastic (MPT) Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Flexible Plastic (MPT) Conduit and Fittings.
    Bend, twist, and wrap machine wiring through tight spaces. Corrugated like ENT, this conduit is more resilient against repeated flexing. Pair it with compatible fittings to seal out liquid and protect wiring indoors and outdoors. Conduit and fittings are made of nylon to resist moisture and chemicals.
    Conduit
    Image of Product. Front orientation. Conduit and Fittings. Flexible Plastic (MPT) Conduit and Fittings, Conduit .
    Run wiring through conduit to route and protect it.
    Per Ft.
    Conduit
    Trade Size
    ID
    OD
    Bend
    Radius
    Temp.,
    ° F
    Enclosure
    Rating
    Specs. Met
    Choose a Length, ft.
    1-99
    100-Up
    Nylon
    1/2
    0.63"0.83"2"-40 to 245IP68, IP69K
    UL Recognized Component, UL 94 V-010, 25, 50, 1006959T180000000000
    1/2
    0.63"0.83"2"-10 to 245IP68, IP69K
    UL Recognized Component, UL 1696, EN 60204, DIN 5510-2, UL 94 HB10, 25, 50, 1006959T1200000000
     

    Ultra-Flexible Plastic (MPT) Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Ultra-Flexible Plastic (MPT) Conduit and Fittings.
    The most flexible conduit we offer. The spiral construction bends, twists, and wraps machine wiring through tight spaces. Pair conduit with compatible fittings to seal out liquid and protect wiring indoors and outdoors. Conduit and fittings are made of PVC or nylon to resist moisture and chemicals.
    Conduit
    Image of Product. Front orientation. Conduit and Fittings. Ultra-Flexible Plastic (MPT) Conduit and Fittings, Conduit .
    Run wiring through conduit to route and protect it.
    Per Ft.
    Conduit
    Trade Size
    ID
    OD
    Bend
    Radius
    Temp.,
    ° F
    Specs. Met
    Choose a Length, ft.
    1-99
    100-Up
     
    PVC
    1/2
    0.63"0.83"2"0 to 155UL Recognized Component
    5, 10, 25, 50, 1007609K30000000000
     

    Electrically Insulating Tube Wire Sleeving

    Add a layer of insulation to prevent electricity and heat from dissipating from wire and cable. This sleeving is often used in motors, transformers, and generators. Made of coated fiberglass, it resists abrasion, acids, alkalies, and chemicals.
    Fiberglass Fabric with Acrylic Plastic Coating
    Image of Product. Front orientation. Wire Sleeving. Electrically Insulating Tube Wire Sleeving.
    Acrylic plastic-coated sleeving is more flexible than vinyl-coated sleeving, so it bends around tight corners. It resists solvents and oil.
    ID
    For Wire
    Dia.
    Wall
    Thk.
    For Max.
    Voltage, V AC
    Temp. Range,
    ° F
    Certification
    Color
    3 ft.
    Long
    25 ft.
    Long
    0.63"5/8"0.03"7,000-10 to 310UL Recognized Component, CSA Certified
    Beige8268K73000000000000
     

    Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings.
    The industry standards, IMC and RMC conduit systems offer the most durable protection indoors, outdoors, and underground. Both types have the same outside diameter, so they use many of the same fittings. This interchangeability makes retrofits easier and reduces the parts you need to keep on hand.
    Conduit
    Image of Product. Front orientation. Conduit and Fittings. Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings, Conduit .
    Run wiring through conduit to route and protect it.
    Galvanized Steel—Strong and resists rust and mild chemicals.
    Aluminum—One-third the weight of steel that's the same size. Aluminum is also nonmagnetic to prevent electrical interference in nearby equipment.
    RMC—The choice when you need maximum impact and crush resistance. The thickest and heaviest conduit option, it’s often found in older installations or used as structural support.
    10 ft. Long
    Conduit
    Trade Size
    Thread
    Type
    Conduit
    Type
    Specs.
    Met
    Each
    Galvanized Steel
    1/2
    NPT
    RMC
    UL Listed
    7307K21000000
     
    Aluminum
    1/2
    NPT
    RMC
    UL Listed
    9175T1100000
     
    Grounding Clamps
    Image of Product. Front orientation. Grounding Clamps.
    Prevent conduit from becoming a shock hazard by running a ground wire through the attached lug to redirect current. The included grommet protects wire and cable from abrasion when being pulled.
    Conduit
    Trade Size
    Thread
    Type
    Gender
    Material
    For Use With
    Specs. Met
    Each
    1/2
    NPSM
    FemaleZincAluminum Wire, Copper WireUL Listed, ANSI/NEMA FB 17513K251000000
    back to top