How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
About Conduit
More
Semi-Flexible Plastic Pipe for Water


- For Use With: Beverage, Drinking Water, Food, Water
- Maximum Temperature: 140° F
- Specifications Met: ASTM D3350, NSF/ANSI 61
- Fittings: Use Nylon Plastic, Polypropylene Plastic, PVC Plastic
While not as flexible as soft tubing, this pipe can still bend around objects, resulting in fewer connection points in your line. Fewer connection points not only shortens installation time, but also allows for smoother flow through the line. Pipe connects to barbed pipe fittings with a clamp (sold separately). It is made of high-density polyethylene (HDPE) for excellent strength and corrosion resistance. It meets NSF/ANSI Standard 61 for drinking water and ASTM D3350 specifications and testing requirements for material quality.
Bend radius is the point to which you can bend pipe or tubing without damaging it. The smaller the measurement, the better the bend.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Lg. | OD | ID | Wall Thick. | Bend Radius | Material | Color | Max. Pressure | Each | |
1 1/4 Pipe Size | |||||||||
---|---|---|---|---|---|---|---|---|---|
5 ft. | 1 21/32" | 1.38" | 0.153" | 33 15/16" | Polyethylene Plastic | Black | 200 psi @ 72° F | 0000000 | 000000 |
10 ft. | 1 21/32" | 1.38" | 0.153" | 33 15/16" | Polyethylene Plastic | Black | 200 psi @ 72° F | 0000000 | 00000 |
25 ft. | 1 21/32" | 1.38" | 0.153" | 33 15/16" | Polyethylene Plastic | Black | 200 psi @ 72° F | 0000000 | 000000 |
100 ft. | 1 21/32" | 1.38" | 0.153" | 33 15/16" | Polyethylene Plastic | Black | 200 psi @ 72° F | 0000000 | 000000 |
Rigid PVC Conduit
For technical drawings and 3-D models, click on a part number.

Also known as PVC Schedule 40 conduit, this conduit is corrosion resistant and UV light resistant for outdoor use. It is lightweight with strong walls to provide protection from damage. It can be buried or encased in concrete.
The female end is expanded so another piece of conduit can be pushed in to connect without a fitting. PVC cement is required (not included) when joining conduit and push-in ends on fittings and access ports.
8-ft. lengths can be shipped via small-parcel carrier.
8 ft. Lg. | ||||
---|---|---|---|---|
ID | OD | Environment | Each | |
1.38" | 1.66" | Outdoor, Underground | 0000000 | 000000 |


Attach PVC Schedule 40 or Schedule 80 conduit to a knockout in an outlet box or enclosure. These adapters are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. PVC cement is required (not included) to secure push-in connections.
Adapters with NPT threads connect unthreaded conduit to threaded fittings and knockouts. Push-in male × flanged end male adapters, also known as box adapters, install through a knockout from inside an electrical enclosure.
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | For Knockout Trade Size | Gender | Each | |
Push-In Conduit Connection × Threaded Electrical Box Connection | |||||||
1 1/4 | Female | 1 1/4 | NPT | __ | Male | 0000000 | 00000 |
Push-In Conduit Connection × Flanged End Electrical Box Connection | |||||||
1 1/4 | Male | __ | __ | 1 1/4 | Male | 0000000 | 0000 |

Join pieces of PVC Schedule 40 or Schedule 80 conduit. These connectors are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. They have push-in ends that slide over conduit. PVC cement is required (not included) to secure the connection.
Conduit Connection | |||
---|---|---|---|
Conduit Trade Size | Gender | Each | |
Push-In Conduit Connection | |||
1 1/4 | Female | 0000000 | 00000 |

Join pieces of PVC Schedule 40 or Schedule 80 conduit. These connectors are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. They have push-in ends that slide over conduit. PVC cement is required (not included) to secure the connection.
Push-In Conduit Connection | Threaded Conduit Connection | ||||||||
---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Material | Color | Specifications Met | Each | |
Push-In Conduit Connection × Threaded Conduit Connection | |||||||||
1 1/4 | Female | 1 1/4 | NPT | Female | PVC | Gray | UL Listed | 0000000 | 00000 |

Join pieces of PVC Schedule 40 or Schedule 80 conduit. These connectors are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. PVC cement is required (not included) to secure the connection.
Conduit Connection | ||||
---|---|---|---|---|
Conduit Trade Size | Gender | Lg. | Each | |
Push-In Conduit Connection | ||||
1 1/4 | Male | 9 1/4" | 0000000 | 00000 |

Connect two different sizes and genders of PVC Schedule 40 or Schedule 80 conduit. These reducing adapters are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. PVC cement is required (not included) to secure the connection.

Also known as conduit bodies, these ports provide access to wire and cable inside PVC Schedule 40 or Schedule 80 conduit for pulling, splicing, and maintenance. They are also used to change the direction of a run. These ports are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. PVC cement is required (not included) to secure the connection.
Conduit Connection | |||
---|---|---|---|
Conduit Trade Size | Gender | Each | |
Push-In Conduit Connection | |||
1 1/4 | Female | 0000000 | 000000 |

Also known as conduit bodies, these ports provide access to wire and cable inside PVC Schedule 40 or Schedule 80 conduit for pulling, splicing, and maintenance. They are also used to change the direction of a run. These ports are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. PVC cement is required (not included) to secure the connection.
Conduit Connection | |||
---|---|---|---|
Conduit Trade Size | Gender | Each | |
Push-In Conduit Connection | |||
1 1/4 | Female | 0000000 | 000000 |

Also known as conduit bodies, these ports provide access to wire and cable inside PVC Schedule 40 or Schedule 80 conduit for pulling, splicing, and maintenance. They are also used to change the direction of a run. These ports are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. PVC cement is required (not included) to secure the connection.
Conduit Connection | |||
---|---|---|---|
Conduit Trade Size | Gender | Each | |
Push-In Conduit Connection | |||
1 1/4 | Female | 0000000 | 000000 |

Also known as conduit bodies, these ports provide access to wire and cable inside PVC Schedule 40 or Schedule 80 conduit for pulling, splicing, and maintenance. They are also used to change the direction of a run. These ports are lightweight, corrosion resistant, and UV light resistant for outdoor use. They can be buried or encased in concrete. PVC cement is required (not included) to secure the connection.
Conduit Connection | |||
---|---|---|---|
Conduit Trade Size | Gender | Each | |
Push-In Conduit Connection | |||
1 1/4 | Female | 0000000 | 000000 |
Rigid Stainless Steel Conduit
For technical drawings and 3-D models, click on a part number.

Use in food-processing and chemical plants—this is the most corrosion resistant thick-wall (rigid) conduit we offer. It is also crush and impact resistant. This conduit has one threaded male end; the other end has a threaded female connector.
5-ft. lengths can be shipped via small-parcel carrier.

Also known as hubs, these adapters attach rigid stainless steel conduit to a knockout in an outlet box or enclosure. They are corrosion resistant, so you can use them in food-processing and chemical plants.
Conduit Connection | Electrical Box Connection | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Material | Specifications Met | Electrical Connector Component | Each | |
Threaded Conduit Connection | |||||||||||
1 1/4 | 1 1/4 | NPT | Female | 1 1/4 | NPSM | Male | 316 Stainless Steel | UL Listed, C-UL Listed | Adapter | 0000000 | 0000000 |

Join pieces of rigid stainless steel conduit. These connectors are corrosion resistant, so you can use them in food-processing and chemical plants.
Conduit Connection | |||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Material | Specifications Met | Each | |
Threaded Conduit Connection | |||||||
1 1/4 | 1 1/4 | NPSM | Female | 316 Stainless Steel | UL Listed, C-UL Listed | 0000000 | 0000000 |

Join pieces of rigid stainless steel conduit. These connectors are corrosion resistant, so you can use them in food-processing and chemical plants.
Conduit Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Lg. | Material | Specifications Met | Each | |
90° Elbow | ||||||||
1 1/4 | 1 1/4 | NPT | Male | 11 5/8" | 316 Stainless Steel | UL Listed, C-UL Listed | 0000000 | 0000000 |
Thin-Wall (EMT) Stainless Steel Conduit
For technical drawings and 3-D models, click on a part number.

The most corrosion-resistant thin-wall conduit we offer, use this along walls and ceilings in food-processing and chemical plants. Also known as electrical metallic tubing (EMT), it has thin walls that are easy to bend with a conduit bender (not included) and cut with a hacksaw.
5-ft. lengths can be shipped via small-parcel carrier.

Conduit × Threaded
Electrical Box Adapter
Attach thin-wall (EMT) stainless steel conduit to a knockout in an outlet box or enclosure. All of these adapters are corrosion resistant, so you can use them in food-processing and chemical plants.
A compression end offers a more reliable hold on conduit than a screw-clamp end. It pushes onto the conduit; tighten the compression ring to secure.
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Material | Each | |
Compression Conduit Connection × Threaded Electrical Box Connection | |||||||
1 1/4 | Female | 1 1/4 | NPT | Male | 316 Stainless Steel | 0000000 | 0000000 |

Join pieces of thin-wall (EMT) stainless steel conduit. All of these connectors are corrosion resistant, so you can use them in food-processing and chemical plants.
Compression ends offer a more reliable hold than screw-clamp or push-in ends. Tighten the compression ring to secure.
Conduit Connection | ||||
---|---|---|---|---|
Conduit Trade Size | Gender | Material | Each | |
Compression Conduit Connection | ||||
1 1/4 | Female | 316 Stainless Steel | 0000000 | 0000000 |

Join pieces of thin-wall (EMT) stainless steel conduit. All of these connectors are corrosion resistant, so you can use them in food-processing and chemical plants.
Conduit Connection | |||||
---|---|---|---|---|---|
Conduit Trade Size | Gender | Lg. | Material | Each | |
Push-In Conduit Connection | |||||
1 1/4 | Male | 10 3/4" | 316 Stainless Steel | 0000000 | 0000000 |
Thin-Wall (EMT) Steel Conduit
For technical drawings and 3-D models, click on a part number.

Also known as electrical metallic tubing (EMT), this conduit has thin walls that easily bend with a conduit bender (not included) and can be cut with a hacksaw. Run it along walls and ceilings, away from high-traffic areas.
5-ft. lengths can be shipped via small-parcel carrier.


Use these adapters to attach thin-wall (EMT) steel conduit to a knockout in an outlet box or enclosure. A compression end offers a more reliable hold on conduit than a screw-clamp end. It pushes onto the conduit; tighten the compression ring to secure. The screw-clamp end tightens around conduit with a screw.
Adapters with grommet protect wire and cable from abrasion when being pulled.
Adapters with O-ring prevent liquid from entering the conduit. They meet UL raintight standards when used with EMT conduit.
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Includes | Each | |
Compression Conduit Connection × Threaded Electrical Box Connection | |||||||
1 1/4 | Female | 1 1/4 | NPSM | Male | Grommet, Locknut | 0000000 | 000000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | Grommet, Locknut, O-Ring | 0000000 | 00000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | Locknut | 0000000 | 0000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | Locknut, O-Ring | 0000000 | 00000 |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
1 1/4 | Female | 1 1/4 | NPSM | Male | Grommet, Locknut | 0000000 | 0000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | Locknut | 0000000 | 0000 |


Use these adapters to attach thin-wall (EMT) steel conduit to a knockout in an outlet box or enclosure. A compression end offers a more reliable hold on conduit than a screw-clamp end. It pushes onto the conduit; tighten the compression ring to secure. The screw-clamp end tightens around conduit with a screw.
Adapters with grommet protect wire and cable from abrasion when being pulled.
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Includes | Each | |
Compression Conduit Connection × Threaded Electrical Box Connection | |||||||
1 1/4 | Female | 1 1/4 | NPSM | Male | Grommet, Locknut | 0000000 | 000000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | Locknut | 0000000 | 00000 |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
1 1/4 | Female | 1 1/4 | NPSM | Male | Grommet, Locknut | 0000000 | 00000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | Locknut | 0000000 | 0000 |


Join pieces of thin-wall (EMT) steel conduit. Compression ends offer a more reliable hold than screw-clamp or push-in ends. Tighten the compression ring to secure. Screw-clamp ends tighten around conduit with screws.
Connectors with O-ring prevent liquid from entering the conduit. They meet UL raintight standards when used with EMT conduit.


Join pieces of thin-wall (EMT) steel conduit. Compression ends offer a more reliable hold than screw-clamp or push-in ends. Tighten the compression ring to secure. Screw-clamp ends tighten around conduit with screws.

Join pieces of thin-wall (EMT) steel conduit.
Conduit Connection | ||||
---|---|---|---|---|
Conduit Trade Size | Gender | Lg. | Each | |
Push-In Conduit Connection | ||||
1 1/4 | Male | 11" | 0000000 | 000000 |

Slide these grommets into thin-wall (EMT) steel conduit ends to protect wire and cable from abrasion when being pulled.
Conduit Connection | ||||
---|---|---|---|---|
Conduit Trade Size | Gender | Color | Each | |
Push-In Conduit Connection | ||||
1 1/4 | Male | White | 0000000 | 00000 |
Continuous-Flex Liquid-Tight Plastic Conduit
For technical drawings and 3-D models, click on a part number.


Also known as Type A, this conduit meets the demands of continuous motion while sealing out liquid when used with liquid-tight fittings. A layer of nylon provides strength during flexing. This conduit is crush and abrasion resistant as well as flame retardant. It also resists oil, chemicals, and UV light.


One end twists into a piece of conduit for a quick connection; the other end attaches to a knockout in an outlet box or enclosure. These fittings seal out liquid when used with continuous-flex liquid-tight plastic conduit.
Acetal fittings resist corrosion and chemicals. Steel fittings are stronger than acetal.


One end twists into a piece of conduit for a quick connection; the other end attaches to a knockout in an outlet box or enclosure. These fittings seal out liquid when used with continuous-flex liquid-tight plastic conduit.
Acetal fittings resist corrosion and chemicals. Steel fittings are stronger than acetal.