Panel-Mount Electrically Actuated Hour Meters













Display running time on a machine so you can schedule preventative maintenance.
Non-resettable counters prevent tampering and accidental loss of data.
Counters that are rated NEMA 4X are protected from dust and washdowns and can be used outdoors.
For Panel Cutout | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | Number of Digits | Dia. | Wd. | Ht. | Ht. | Wd. | Dp. | Dia. | Operating Voltage | Environmental Rating | Each | ||
Screw On | ||||||||||||||
Wire Leads | ||||||||||||||
A | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2" | 2.9" | 24V AC | __ | 0000000 | 0000000 |
A | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2" | 2.9" | 120V AC | __ | 0000000 | 00000 |
A | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2" | 2.9" | 230V AC | __ | 0000000 | 000000 |
B | No | Up | 6 | __ | 2.3" | 2.3" | __ | __ | 2.5" | 3" | 120V AC | __ | 0000000 | 00000 |
B | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2.5" | 3.5" | 120V AC | __ | 0000000 | 00000 |
E | No | Up | 5 | __ | 1.5" | 1" | __ | __ | 1.9" | 2.9" | 120V AC | __ | 0000000 | 00000 |
F | No | Up | 5 | __ | 1.5" | 1" | 1.1" | 2.1" | 1.9" | __ | 120V AC | __ | 0000000 | 00000 |
Screw Terminals | ||||||||||||||
A | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2" | 2.9" | 120V AC | __ | 0000000 | 00000 |
N | Yes | Up | 8 | __ | 1.8" | 0.9" | 1" | 1.9" | 2.1" | __ | 10-240V AC, 5-110V DC | __ | 00000000 | 00000 |
0.25" Quick-Disconnect Terminals | ||||||||||||||
C | No | Up | 6 | __ | 1.5" | 1" | 0.92" | 1.43" | 2.15" | __ | 10-80V DC | __ | 0000000 | 00000 |
C | No | Up | 6 | __ | 1.5" | 1" | 0.92" | 1.43" | 2.15" | __ | 115-230V AC | __ | 0000000 | 00000 |
E | No | Up | 5 | __ | 1.5" | 1" | __ | __ | 1.9" | 2.9" | 8-32V DC | __ | 0000000 | 00000 |
F | No | Up | 5 | __ | 1.5" | 1" | 1.1" | 2.1" | 1.9" | __ | 8-32V DC | __ | 0000000 | 00000 |
G | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.8" | 24V AC | IP65, NEMA 4X | 0000000 | 00000 |
G | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.8" | 120V AC | IP65, NEMA 4X | 0000000 | 00000 |
G | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.8" | 230V AC | IP65, NEMA 4X | 0000000 | 00000 |
G | No | Up | 6 | 2" | __ | __ | __ | __ | 2" | 2.8" | 10-80V DC | __ | 0000000 | 00000 |
L | No | Up | 6 | __ | 1.5" | 1" | 1.3" | 2.1" | 0.8" | __ | 15-75V AC, 9-60V DC | __ | 0000000 | 00000 |
L | No | Up | 6 | __ | 1.5" | 1" | 1.3" | 2.1" | 0.8" | __ | 75-270V AC, 36-185V DC | __ | 0000000 | 00000 |
Press On | ||||||||||||||
Screw Terminals | ||||||||||||||
D | No | Up | 7 | __ | 1.8" | 0.9" | 2.1" | 2.1" | 1.6" | __ | 24V AC | __ | 0000000 | 000000 |
D | No | Up | 7 | __ | 1.8" | 0.9" | 2.1" | 2.1" | 1.6" | __ | 120V AC | __ | 0000000 | 000000 |
D | No | Up | 7 | __ | 1.8" | 0.9" | 2.1" | 2.1" | 1.6" | __ | 230V AC | __ | 0000000 | 000000 |
0.25" Quick-Disconnect Terminals | ||||||||||||||
H | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.4" | 24V AC | __ | 0000000 | 00000 |
H | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.4" | 120V AC | __ | 0000000 | 00000 |
H | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.4" | 230V AC | __ | 0000000 | 00000 |
J | No | Up | 5 | 2" | __ | __ | __ | __ | 2" | 2.3" | 8-32V DC | __ | 0000000 | 00000 |
M | No | Up | 6 | 2.1" | __ | __ | __ | __ | 0.6" | 2.3" | 15-75V AC, 9-60V DC | __ | 0000000 | 00000 |
M | No | Up | 6 | 2.1" | __ | __ | __ | __ | 0.6" | 2.3" | 75-270V AC, 36-185V DC | __ | 0000000 | 00000 |
Clip | ||||||||||||||
0.25" Quick-Disconnect Terminals | ||||||||||||||
K | No | Up | 6 | 2" | __ | __ | __ | __ | 2" | 2.3" | 10-80V DC | __ | 0000000 | 00000 |
DIN-Rail-Mount Electrically Actuated Hour Meters

Quickly install these meters onto a DIN rail instead of on a surface or into panels. Use them to display running time on a machine so you can schedule preventative maintenance. They are non-resettable to prevent tampering and accidental loss of data.
Electrically Actuated Hour Meters with Output Relay

Display running time on a machine so you can schedule preventative maintenance. These counters have two displays. One display shows the total running time and cannot be reset; the other shows the time elapsed since the last maintenance and can be wired for remote reset. The output relay turns on an indicator light and sends a signal to another device when the counter reaches a set point. The signal can start/stop a process or trigger an alarm.
Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | No. of Set Points | For Panel Cutout Dia. | Dp. | Dia. | Operating Voltage | Output Relay Current | Environmental Rating | Each | |
Press On | |||||||||||
Wire Leads | |||||||||||
No | Up | 6 | 1 | 2" | 1.7" | 2.3" | 85-265V AC, 90-360V DC | 0.2 A @ 265 V AC, 0.2 A @ 40 V DC | IP67, NEMA 12, NEMA 4X | 00000000 | 0000000 |
No | Up | 6 | 1 | 2" | 1.7" | 2.3" | 10-40V DC | 0.2 A @ 265 V AC, 0.2 A @ 40 V DC | IP67, NEMA 12, NEMA 4X | 00000000 | 000000 |
Electric-Motor-Actuated Hour Meters

With a sensor that’s activated by your electric motor’s magnetic field, these meters show the motor’s running time. To mount the meter sensor to your motor, use the adhesive back.
Non-resettable counter prevents tampering and accidental loss of data.
Resettable counter alerts the user when the count reaches a set point.
Electrically Actuated Minute Meters


Display running time on a machine so you can schedule preventative maintenance.
Non-resettable counter prevents tampering and accidental loss of data.
Switch-Contact-Actuated Hour Meters

This meter does not require voltage to register a count. It is protected from dust, water, and splashing oil and coolant (meets IP65, NEMA 4X, NEMA 12). Use it to display running time on a machine so you can schedule preventative maintenance.
For Panel Cutout | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | Number of Digits | Ht. | Wd. | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Screw On | |||||||||||
Screw Terminals | |||||||||||
Yes | Up | 8 | 0.9" | 1.8" | 1" | 1.9" | 2.1" | IP65, NEMA 4X, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CE Marked | 00000000 | 000000 |
Vibration-Actuated Hour Meters



Record the running time of machines and vehicles that vibrate while operating. They are protected from dust and water (meets IP67). Counters are non-resettable to prevent tampering and accidental loss of data.
Counters/Hour Meters

Keep track of time while counting events. Units have two displays: one that receives input from a sensor, encoder, or switch and another that counts hours.
For technical drawings and 3-D models, click on a part number.