McMaster-Carr logo
    Filter by
    Display Type
    Relative Humidity Accuracy
    Wire Connection
    Electrical Connection
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Maximum Temperature
    DFARS Specialty Metals
    Actuation Point Adjustability
    Operating Temperature
    Adjustability
    Overall Width
    Overall Height
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    8 Products

    Panel-Mount Humidity Controllers

    The sensors monitor relative humidity and trigger the controllers to turn equipment on or off. Sensors and controllers are sold separately.
    Controllers
    Image of Product. Front orientation. Humidity Controllers. Panel-Mount Humidity Controllers, Controllers.
    Controllers are SPDT (single pole, double throw). They can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). Set the actuation point with the keypad.
    Relative
    Humidity
    For Panel
    Cutout
    No. of
    Range
    Accuracy
    Max. Operating
    Temp., ° F
    Ht.
    Wd.
    Actuation
    Points
    Circuits
    Controlled
    Wire
    Connection
    Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Each
    10% to 100%±1%1581 9/64"2 13/16"21Screw Terminal1201 11/32"3"2 3/8"Plastic39635K440000000
    Sensors
    Image of Product. Front orientation. Humidity Controllers. Panel-Mount Humidity Controllers, Sensors.
    Relative
    Humidity
    Range
    Accuracy
    Max. Operating
    Temp., ° F
    Wire
    Connection
    Wire Lead
    Lg.
    Cable Lg.,
    ft.
    Ht.
    Wd.
    Housing
    Material
    Fasteners
    Included
    Each
    20% to 90%±5%122Wire Leads1/16"42 3/8"31/32"PlasticNo39635K33000000

    Humidistats

    Image of Product. Front orientation. Humidistats. Humidistats , For Humidifiers and Dehumidifiers .
    Image of Product. Front orientation. White. Humidistats , For Humidifiers.

    For

    Humidifiers

    and

    Dehumidifiers

    For Humidifiers

    Turn the dial to control humidity equipment.
    For Humidifiers and Dehumidifiers—Humidistats for humidifiers and dehumidifiers mount to a surface-mount outlet box.
    Overall
    Voltage
    Current
    RH
    Switch
    Designation
    Color
    Ht.
    Wd.
    Dp.
    Mounting
    Location
    Mounting Fasteners
    Included
    Each
    For Humidifiers
    24V AC to 30V AC1 amp10% to 75%SPDT
    White3"4 3/4"1 3/4"Duct, WallYes2123K18000000
     
    For Humidifiers and Dehumidifiers
    120V AC/208V AC/240V AC6 amp/3.5 amp/3 amp0% to 70%SPDT
    Beige4 3/4"3"3"Outlet BoxYes2123K14000000
     

    Enclosure Humidistats

    Image of ProductInUse. Front orientation. Humidistats. Enclosure Humidistats , Fixed Actuation Point.
    Image of ProductInUse. Front orientation. Humidistats. Enclosure Humidistats , Adjustable Actuation Point.

    Fixed Actuation Point

    Adjustable Actuation

    Point

    Reduce the humidity in your enclosure to prevent condensation that can cause corrosion and short circuits. These humidistats switch your heater on when the enclosure reaches the relative humidity setting. Once the humidity falls by 5%, the heater switches off. To install, clip humidistats to a DIN rail.
    CSA Certified, CSA-US Certified, CE Marked, and VDE Certified, these humidistats meet American, Canadian, and European safety standards. They also meet UL 94 V-0, so if they catch fire, they self-extinguish within 10 seconds and won’t spread the fire by dripping.
    Fixed Actuation Point—Fixed humidistats work for most applications. They keep humidity below 65%, which is when condensation is most likely to form. Since they aren’t adjustable, the humidity setting can’t be tampered with or accidentally changed.
    Adjustable Actuation Point—For critical components, use adjustable humidistats to set the relative humidity you need in your enclosure. Use a lower humidity setting in damp environments and places with frequent temperature changes. Condensation is more likely in these situations.
    RH
    Overall
    Setting
    Difference
    Tolerance
    Voltage
    Current
    For DIN
    Rail Ht., mm
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Flammability
    Rating
    Mounting Location
    Each
    Fixed
    65%5%-1% to 1%120V AC16 amp35SPDT
    2 1/2"1 5/8"1 1/2"IP20
    CE Marked, VDE Certified, CSA Certified, CSA-US Certified
    UL 94 V-0
    DIN Rail, Enclosure3869N14000000
    65%5%-1% to 1%240V AC16 amp35SPDT
    2 1/2"1 5/8"1 1/2"IP20
    CE Marked, VDE Certified, CSA Certified, CSA-US Certified
    UL 94 V-0
    DIN Rail, Enclosure3869N1300000
     
    Adjustable
    40% to 90%5%-1% to 1%120V AC16 amp35SPDT
    2 1/2"1 5/8"1 1/2"IP20
    CE Marked, VDE Certified, CSA Certified, CSA-US Certified
    UL 94 V-0
    DIN Rail, Enclosure3869N1200000
    40% to 90%5%-1% to 1%240V AC16 amp35SPDT
    2 1/2"1 5/8"1 1/2"IP20
    CE Marked, VDE Certified, CSA Certified, CSA-US Certified
    UL 94 V-0
    DIN Rail, Enclosure3869N1100000
     
    back to top