    HVAC Sealants

    Form flexible water-resistant seals on metal, plastic, and rubber joints in heating, ventilation, air conditioning, and refrigeration applications. These sealants are non-sagging, so they won't drip from vertical and overhead surfaces. Made from silicone rubber, sealants are RTV (room-temperature vulcanizing).
    Elongation and joint compression/expansion tolerance indicate flexibility—the higher the values are, the more joint movement sealants can sustain.
    Dow Silicone Rubber
    Image of Product. Front orientation. Sealants. HVAC Sealants.
    Container
    Size, fl.
    oz.
    Type
    Begins to
    Harden, min.
    Reaches Full
    Strength, hr.
    Elongation
    Joint Compression/Expansion
    Tolerance
    Tensile Strength,
    psi
    Hardness Rating
    Temp. Range,
    ° F
    Certification
    Food Industry Std.
    Flammability
    Rating
    For Joining
    Choose a Color (Clarity)
    Each
    10.3Cartridge524600%-25% to 25%325Soft (Durometer 27A)-40 to 350UL Listed
    FDA Compliant 21 CFR 177.2600
    UL 94 HB
    Composite
    Metal
    Plastic
    Rubber
    Metal to Composite
    Metal to Plastic
    Metal to Rubber
    Aluminum, Clear, White (Semi-Clear)1919N3000000
    Sealant Primers
    Silicone Rubber
    Image of Product. Front orientation. Sealants. HVAC Sealants.
    Container
    Size, fl.
    oz.
    Type
    Begins to
    Harden, min.
    Reaches Full
    Strength, hr.
    Elongation
    Joint Compression/Expansion
    Tolerance
    Tensile
    Strength
    Hardness Rating
    Temp. Range,
    ° F
    Mil. Spec.
    For Joining
    Choose a Color (Clarity)
    Each
    9.4Cartridge2024Not Rated-25% to 25%Not RatedSoft (Durometer 26A)-60 to 400Fed. Spec. TT-S-00230
    Fed. Spec. TT-S-001543 Class A
    Composite
    Metal
    Plastic
    Rubber
    Metal to Composite
    Metal to Plastic
    Metal to Rubber
    Clear (Clear), Gray (Opaque), White (Opaque)1919N1600000

    Metal Duct HVAC Sealants

    Image of Product. Front orientation. Sealants. Metal Duct HVAC Sealants, Cartridge.
    Image of Product. Front orientation. Sealants. Metal Duct HVAC Sealants, Pail.

    Cartridge

    Pail

    Seal metal-to-metal joints in ductwork. These sealants are non-sagging, so they won't drip from vertical and overhead surfaces.
    Container
    Temp.,
    ° F
    Size
    Type
    Begins to
    Harden, min.
    Reaches Full
    Strength, hr.
    Elongation
    Joint Compression/Expansion
    Tolerance
    Tensile
    Strength
    Hardness Rating
    Min.
    Max.
    For
    Joining
    Color
    (Clarity)
    Each
    Acrylic Plastic
    10.1 fl. oz.Cartridge1548Not RatedNot RatedNot RatedSoft (Durometer 20A)-40200MetalGray (Opaque)73335A6500000
    1 gal.Pail1548Not RatedNot RatedNot RatedSoft (Durometer 20A)-40200MetalGray (Opaque)73335A6600000
     

    Foil HVAC Tape

    Image of Product. No Liner. Front orientation. HVAC Tape. Foil HVAC Tape, Unlined.
    Image of Product. With Liner. Front orientation. HVAC Tape. Foil HVAC Tape, 150 ft. Long.

    No Liner

    With Liner

    Seal foil-jacketed insulation as well as air-conditioning and refrigeration systems with this conformable aluminum tape.
    Acrylic Plastic Adhesive—Tape with acrylic plastic adhesive withstands higher temperatures than tape with rubber adhesive.
    Silicone Adhesive—Tape with silicone adhesive stands up to the widest temperature range.
    Wd.
    Overall
    Thk.
    Temp. Range,
    ° F
    Tensile Strength,
    lbf/in. wd.
    Adhesion to
    Steel, ozf/in. wd.
    Liner
    Type
    Specs. Met
    Mil. Spec.
    Color
    Lg.,
    ft.
    Each
    Rubber Adhesive
    2"0.004"40 to 18010100PaperSilver15076145A61000000
    3"0.004"40 to 18010100PaperSilver15076145A6200000
     
    Acrylic Plastic Adhesive
    1"0.003"-30 to 32510Not RatedNo LinerSilver157631A710000
    1"0.003"-30 to 32510Not RatedNo LinerSilver1807631A3100000
    1"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver157631A810000
    1"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver1807631A1900000
    1"0.006"-30 to 32550Not RatedNo LinerSilver157631A910000
    1"0.006"-30 to 32550Not RatedNo LinerSilver1807631A4100000
    2"0.0027"-40 to 2501595PaperSilver1507616A2100000
    2"0.003"-30 to 32510Not RatedNo LinerSilver157631A720000
    2"0.003"-30 to 32510Not RatedNo LinerSilver1807631A3200000
    2"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver157631A820000
    2"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver1807631A2100000
    2"0.006"-30 to 32550Not RatedNo LinerSilver157631A9200000
    2"0.006"-30 to 32550Not RatedNo LinerSilver1807631A4200000
    2 1/2"0.0032"-40 to 2502151PaperSilver1507616A2500000
    3"0.0027"-40 to 2501595PaperSilver1507616A3100000
    3"0.003"-30 to 32510Not RatedNo LinerSilver157631A730000
    3"0.003"-30 to 32510Not RatedNo LinerSilver1807631A3300000
    3"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver157631A8300000
    3"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver1807631A2300000
    3"0.006"-30 to 32550Not RatedNo LinerSilver157631A9300000
    3"0.006"-30 to 32550Not RatedNo LinerSilver1807631A43000000
    4"0.003"-30 to 32510Not RatedNo LinerSilver157631A3400000
    4"0.003"-30 to 32510Not RatedNo LinerSilver1807631A9400000
    4"0.0032"-40 to 2602151PlasticSilver1507616A2600000
    4"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver157631A8400000
    4"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver1807631A2400000
    4"0.006"-30 to 32550Not RatedNo LinerSilver157631A4400000
    4"0.006"-30 to 32550Not RatedNo LinerSilver1807631A95000000
    6"0.003"-30 to 32510Not RatedNo LinerSilver157631A6100000
    6"0.003"-30 to 32510Not RatedNo LinerSilver1807631A66000000
    6"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver157631A6200000
    6"0.005"-30 to 32525Not RatedNo LinerSAE AMS-T-23397Fed. Spec. L-T-80Silver1807631A67000000
    6"0.006"-30 to 32550Not RatedNo LinerSilver157631A6300000
    6"0.006"-30 to 32550Not RatedNo LinerSilver1807631A68000000
     
    Silicone Adhesive
    1"0.004"-65 to 6002040No LinerSilver157594A800000
    1"0.004"-65 to 6002040No LinerSilver1807594A4000000
     

    Reinforced HVAC Tape

    Image of Product. Front orientation. HVAC Tape. Reinforced HVAC Tape.
    Use this tape for sealing and patching insulation and duct.
    Metalized Polypropylene, Kraft Paper—Polypropylene tape is metalized and has an acrylic adhesive formulated for use in cold temperatures.
    Aluminum, Kraft Paper—Aluminum foil tape is also known as FSK tape.
    Fiberglass Reinforcement—Reinforced with fiberglass, this tape is flexible yet resists tearing.
    Wd.
    Lg.,
    ft.
    Overall
    Thk.
    Reinforcement
    Material
    Adhesive
    Material
    Temp. Range,
    ° F
    Tensile Strength,
    lbf/in. wd.
    Adhesion to
    Steel, ozf/in. wd.
    Flammability Rating
    Color
    Each
    Metalized Polypropylene, Kraft Paper
    3"1500.0107"FiberglassAcrylic Plastic
    -40 to 1854066UL 723 10/10 for Flame and Smoke
    White7620A11000000
     
    Aluminum, Kraft Paper
    2"1500.006"FiberglassAcrylic Plastic
    -40 to 2404066UL 723 10/10 for Flame and Smoke
    Silver76145A4100000
    3"300.0068"FiberglassRubber
    -4 to 176Not Rated90Silver76145A1900000
    3"1500.006"FiberglassAcrylic Plastic
    -40 to 2404066UL 723 10/10 for Flame and Smoke
    Silver76145A4200000
    4"1500.006"FiberglassAcrylic Plastic
    -40 to 2404066UL 723 10/10 for Flame and Smoke
    Silver76145A4300000
    6"1500.006"FiberglassAcrylic Plastic
    -40 to 2404066UL 723 10/10 for Flame and Smoke
    Silver76145A4400000
     

    UL-Printed HVAC Tape

    Image of Product. Front orientation. HVAC Tape. UL-Printed HVAC Tape.
    For easy identification, this tape is printed with UL flexible duct standards. Use it for insulation and jacketing. It holds up to UV rays.
    Aluminum—Aluminum foil tape is more conformable than polypropylene plastic tape.
    Material Certificate Icon
    Certificates with a traceable lot number and product shelf life are available for these products. Download certificates from ORDER HISTORY after your order ships.
    Wd.
    Lg.,
    ft.
    Overall
    Thk.
    Material
    Adhesive
    Material
    Temp. Range,
    ° F
    Tensile Strength,
    lbf/in. wd.
    Adhesion to
    Steel, ozf/in. wd.
    Features
    Color (Message Color)
    Each
    UL 181A-P, UL 181B-FX
    2 1/2"1800.004"Aluminum
    Acrylic Plastic
    -30 to 3002560UV-ResistantSilver (Red)76145A33000000
    3"1800.004"Aluminum
    Acrylic Plastic
    -30 to 3002560UV-ResistantSilver (Red)76145A3600000
     
    UL 181B-FX
    2"3600.003"Polypropylene
    Acrylic Plastic
    -40 to 1852030UV-ResistantBlack (Silver), Silver (Red)7575A5100000
    3"3600.003"Polypropylene
    Acrylic Plastic
    -40 to 1852030UV-ResistantBlack (Silver), Silver (Red)7575A5200000
     

    Antibacterial Protective Coatings

    Prevent the growth of harmful and odor-causing bacteria, mold, and fungus on HVAC system components and hardware. These coatings contain silver, which inhibits the growth of mildew, mold, and fungus.
    These coatings have excellent chemical resistance. They’re often used on panels, ducts, and drain pans. Apply with a brush, roller, or sprayer. The size listed is the combined total of the two parts.
    Epoxy—Can
    Image of Product. Front orientation. Protective Coatings. Antibacterial Protective Coatings, Epoxy—Can.
    Cannot Be Sold To—Coatings cannot be sold to the listed areas due to product registration requirements and/or regulatory limits on VOC (volatile organic compounds).
    Dry Time
    Container
    Size, gal.
    Solution
    Type
    Touch,
    hr.
    Overall,
    day
    Approx. Coverage
    @ Thk.
    Mixing
    Req.
    Mix
    Ratio
    Application Time
    After Mixing, hr.
    Max. Temp.,
    ° F
    Application
    Temp. Range, ° F
    For Use
    Outdoors
    For Use On
    Color
    Cannot Be Sold To
    Each
    1 1/2Water Based17570 ft² @ 1 milYes2:1430050 to 100NoAluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Galvanized Iron, Galvanized SteelSemi-Gloss GrayCanada; Los Angeles County, CA; Orange County, CA; Riverside County, CA; San Bernardino County, CA2561N210000000
    1 1/2Water Based17640 ft² @ 1 milYes2:1430050 to 100NoAluminum, Brass, Bronze, Copper, Steel, Stainless Steel, Galvanized Iron, Galvanized SteelGloss WhiteCanada; Los Angeles County, CA; Orange County, CA; Riverside County, CA; San Bernardino County, CA2561N22000000
     

    Leak-Detecting Dye Kits for HVAC Systems

    Image of Product. Dye Kit with Sealant. Front orientation. Leak-Detecting Dyes. Leak-Detecting Dye Kits for HVAC Systems, Liquid, Fluorescent Blue/Green.

    Dye Kit with Sealant

    With bright-colored dye and a fully equipped kit, you have everything you need to spot leaks in your HVAC system. These kits come with the correct amount of dye required for your system's size. Inject the dye into your system and scan it with the UV light—the dye is fluorescent, so it’s easy to spot most leaks right away. For small leaks, let the dye circulate for 24 hours and then inspect it again. Use the dye cleaner before you fix a leak. If the repair isn’t sufficient, you’ll be able to spot more dye.
    Four 0.5 oz. UV Dye and Sealant Containers—Kits with UV dye and sealant are formulated to seal hard-to-find leaks from the inside of your system. The dye and sealant formula is non-polymer and oil soluble, making it safe to stay in your system indefinitely. Reinforce seals from the outside for a permanent fix.
    ANSI/ASHRAE Standard 86 and ANSI/ASHRAE Standard 97—Kits that meet ANSI/ASHRAE adhere to standards for chemical stability.
    Dyes
    Replacement Dyes
    Color
    For Max. HVAC System
    Size, BTU/hr
    Container
    Size, fl. oz.
    Includes
    Specs. Met
    Each
    Each
    Liquid
    Fluorescent Blue/Green168,0000.5Four 0.5 oz. UV Dye and Sealant Containers, Adapter, Carrying Case, Cleaner, Hose Assembly, Injector, UV Light, UV Protective GlassesANSI/ASHRAE Standard 86, ANSI/ASHRAE Standard 977546N1300000007546N14000000
     

    Reinforced Insulation Tape

    Image of Product. Front orientation. HVAC Tape. Reinforced Insulation Tape.
    Seal fiberglass duct and insulation that's faced with an all-service jacket (ASJ).
    Fiberglass Reinforcement—Tape is reinforced with fiberglass.
    Wd.
    Lg.,
    ft.
    Overall
    Thk.
    Reinforcement
    Material
    Adhesive
    Material
    Temp. Range,
    ° F
    Tensile Strength,
    lbf/in. wd.
    Adhesion to
    Steel, ozf/in. wd.
    Certification
    Color
    Each
    Aluminum, Kraft Paper
    3"300.009"FiberglassRubber
    30 to 1754550UL Listed
    White76755A67000000
    3"1500.012"FiberglassAcrylic Plastic
    30 to 1755545UL Listed
    White76755A6500000
    5"1500.012"FiberglassAcrylic Plastic
    30 to 1755545UL Listed
    White76755A6600000
     