About Flow-Adjustment Valves
More
Inground Frostproof Faucets with Garden Hose Outlet

These faucets drain when closed to prevent freezing.
Inlet | |||||||||
---|---|---|---|---|---|---|---|---|---|
Max. Burying Dp., ft. | O'all Ht. | Pipe Size | Thread Type | Gender | Max. Pressure | Temp. Range, °F | Pipe Casing Material | Each | |
Iron Faucet with Stainless Steel Pipe | |||||||||
2 | 52 3/4" | 3/4 | NPT | Female | 120 psi @ 140° F | -40° to 140° | Galvanized Steel | 0000000 | 0000000 |
3 | 64 1/2" | 3/4 | NPT | Female | 120 psi @ 140° F | -40° to 140° | Galvanized Steel | 0000000 | 000000 |
4 | 77" | 3/4 | NPT | Female | 120 psi @ 140° F | -40° to 140° | Galvanized Steel | 0000000 | 000000 |
5 | 89" | 3/4 | NPT | Female | 120 psi @ 140° F | -40° to 140° | Galvanized Steel | 0000000 | 000000 |
Through-Wall Frostproof Faucets with Garden Hose Outlet


These faucets drain when closed to prevent freezing. Inlet is dual threaded.
To prevent tampering, Style B require a key to open and close.
Inlet | |||||||
---|---|---|---|---|---|---|---|
For Wall Thick. | Pipe Size (Gender) | Thread Type | Max. Pressure | Temp. Range, °F | For Use Outdoors | Each | |
Brass with Copper Pipe | |||||||
Style A | |||||||
6" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 000000 |
8" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
10" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
12" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
14" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
Style A with Vacuum Breaker | |||||||
6" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
8" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
10" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
12" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
14" | 1/2 (Female), 3/4 (Male) | NPT | 85 psi @ 140° F | 35° to 140° | Yes | 0000000 | 00000 |
Chrome-Plated Brass with Brass Pipe | |||||||
Style B with Keyed Lock (Key Included) | |||||||
4" | 3/4 (Female), 1 (Male) | NPT | 125 psi @ 140° F | 35° to 140° | Yes | 000000000 | 000000 |
6" | 3/4 (Female), 1 (Male) | NPT | 125 psi @ 140° F | 35° to 140° | Yes | 000000000 | 000000 |
8" | 3/4 (Female), 1 (Male) | NPT | 125 psi @ 140° F | 35° to 140° | Yes | 000000000 | 000000 |
10" | 3/4 (Female), 1 (Male) | NPT | 125 psi @ 140° F | 35° to 140° | Yes | 000000000 | 000000 |
12" | 3/4 (Female), 1 (Male) | NPT | 125 psi @ 140° F | 35° to 140° | Yes | 000000000 | 000000 |
Replacement Key for Style B | 00000000 | Each | 000000 |
On/Off Faucets with Garden Hose Outlet



These faucets turn on and off with a quarter turn of the handle.
For Style C with tube inlet connection, tube size is the accepted designation of the copper tubing industry, not the actual OD.
Inlet | ||||||||
---|---|---|---|---|---|---|---|---|
Style | Pipe Size | Thread Type | Gender | Ht. | Max. Pressure | Temp. Range, °F | Each | |
Pipe Inlet Connection | ||||||||
Brass | ||||||||
A | 1/2 | NPT | Male | 1 1/4" | 125 psi @ 100° F | 40° to 180° | 0000000 | 000000 |
A | 3/4 | NPT | Male | 1 1/4" | 125 psi @ 100° F | 40° to 180° | 0000000 | 00000 |
B | 1/2 | NPT | Female | 1 1/4" | 125 psi @ 100° F | 40° to 180° | 0000000 | 00000 |
B | 1/2 | NPT | Male | 1 1/2" | 125 psi @ 100° F | 40° to 180° | 00000000 | 00000 |
B | 3/4 | NPT | Female | 1 1/4" | 125 psi @ 100° F | 40° to 180° | 0000000 | 00000 |
B | 3/4 | NPT | Male | 1 1/2" | 125 psi @ 100° F | 40° to 180° | 00000000 | 00000 |
C | 1/2 | NPT | Female | 2 3/8" | 125 psi @ 100° F | 40° to 180° | 0000000 | 00000 |
C | 3/4 | NPT | Female | 2 5/8" | 125 psi @ 100° F | 40° to 180° | 0000000 | 00000 |
Stainless Steel | ||||||||
A | 1/2 | NPT | Male | 1 9/16" | 200 psi @ 100° F | 40° to 250° | 00000000 | 00000 |
A | 3/4 | NPT | Male | 1 5/8" | 200 psi @ 100° F | 40° to 250° | 00000000 | 00000 |
Fire Hydrants
Fight fires in areas around your facility that city-installed hydrants don’t reach. These hydrants are dry-barrel, the most common type of hydrant, which means they drain water when not in use. Not only does this prevent freezing, but it keeps water from spurting out if a vehicle hits these hydrants. And if they get hit, they won’t need much repair—their safety flange and safety stem coupling break without shattering. That means the hydrant comes off cleanly, minimizing damage to the main body and stem. To repair, just replace the flange and coupling using the repair kit (sold separately).
These hydrants must be installed and maintained according to National Fire Protection Association (NFPA) Standards. If your main line is below 5 ft., attach a stem extension (sold separately). An extension can also raise your hydrant above the ground.
These hydrants are FM approved and meet AWWA C-502 standards for the durability, reliability, and safety of dry-barrel fire hydrants. Connect them to the plain end of a water main line with their mechanical joint connection. The fitting will maintain a tight seal through normal underground movement and temperature changes.


Inlet Pipe Size | Fire Hose Trade Size (No. of Outlets) | Bury Dp., ft. | Ht. Above Ground | Drive Size | Drive Style | Valve Opening Direction | Body Material | Color | Fire Hydrant Valve Size | Operating Pressure, psi | Max. Temp., °F | Specifications Met | Each | |
Mechanical Joint Pipe Inlet × NH/NST Female Hose Outlet | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 2 1/2 (2) 4 1/2 (1) | 5 | 32" | 1 1/2" | External Pentagon | Counterclockwise | Epoxy-Coated Ductile Iron | Red | 5 1/4" | 200 | 130° | AWWA C502, FM Approved | 0000000 | 000000000 |

Includes | Each | |
Safety Stem Coupling, Safety Flange, Gasket, Mounting Hardware | 0000000 | 0000000 |
Plastic Threaded Flow-Adjustment Valves with Garden Hose Outlet




- Valve Type: Globe
- For Use With: Water
For a lightweight and corrosion-resistant alternative to metal, these valves are plastic. With an NPT inlet and a GHT outlet, they are often attached to garden hose. All gradually open and close with multiple turns of the wheel handle to adjust and regulate flow. Their nonrising stem stays in the same position whether the valve is open or closed.
Pipe Size | Hose Size | Max. Pressure | Temperature Range, °F | End-to-End Lg. | Port-to-Port Length | Overall Height | Stem Type | Each | |
Acetal Plastic Body—Straight | |||||||||
---|---|---|---|---|---|---|---|---|---|
NPT Female × GHT Male | |||||||||
1/2 | 3/4 | 100 psi @ 140° F | 40° to 140° | 2 3/16" | __ | 4 9/16" | Nonrising | 0000000 | 00000 |
3/4 | 3/4 | 100 psi @ 140° F | 40° to 140° | 2 3/16" | __ | 4 9/16" | Nonrising | 0000000 | 0000 |
NPT Male × GHT Male | |||||||||
1/2 | 3/4 | 100 psi @ 140° F | 40° to 140° | 2 3/16" | __ | 3 15/16" | Nonrising | 0000000 | 0000 |
3/4 | 3/4 | 100 psi @ 140° F | 40° to 140° | 2 3/16" | __ | 3 15/16" | Nonrising | 0000000 | 0000 |
Acetal Plastic Body—70° Elbow | |||||||||
NPT Female × GHT Male | |||||||||
1/2 | 3/4 | 100 psi @ 140° F | 40° to 140° | 2 3/16" | 2" | 4 3/8" | Rising | 0000000 | 0000 |
3/4 | 3/4 | 100 psi @ 140° F | 40° to 140° | 2 3/16" | 1 7/16" | 4 5/16" | Nonrising | 0000000 | 0000 |
NPT Male × GHT Male | |||||||||
1/2 | 3/4 | 100 psi @ 140° F | 40° to 140° | 2 3/16" | 1 7/16" | 4 5/16" | Nonrising | 0000000 | 0000 |
3/4 | 3/4 | 100 psi @ 140° F | 40° to 140° | 2 3/16" | 1 7/8" | 4 5/16" | Nonrising | 0000000 | 0000 |
Threaded Flow-Adjustment Valves with Garden Hose Outlet
- For Use With: Oil, Water
- Valve Type: Globe
These valves have an NPT inlet and a GHT outlet for attaching garden hose. They gradually open and close with multiple turns of the wheel handle to adjust and regulate flow. All have a nonrising stem that stays in the same position whether the valve is open or closed.
Lockouts (sold separately) thread over the valve outlet and lock in place with a padlock (not included) to prevent unauthorized water use.


Pipe Size | Hose Size | Max. Pressure | Temperature Range | Port-to-Port Lg. | Stem Type | Each | |
Brass Body | |||||||
---|---|---|---|---|---|---|---|
NPT Female × GHT Male | |||||||
1/2 | 3/4 | 125 psi @ 100° F | 40° F to 180° F | 1 1/2" | Nonrising | 0000000 | 000000 |
3/4 | 3/4 | 125 psi @ 100° F | 40° F to 180° F | 1 1/2" | Nonrising | 0000000 | 00000 |
NPT Male × GHT Male | |||||||
1/2 | 3/4 | 125 psi @ 100° F | 40° F to 180° F | 1 9/16" | Nonrising | 0000000 | 00000 |
3/4 | 3/4 | 125 psi @ 100° F | 40° F to 180° F | 1 9/16" | Nonrising | 0000000 | 00000 |
For Maximum Shackle Diameter | For Hose Size | For Thread Type | Chemical Resistance (Excellent) | Each | |
9/32" | 3/4 | GHT | Air, Water | 0000000 | 000000 |
Threaded Flow-Adjustment Valves with Fire-Fighting Hose Fittings
- Valve Type: Gate
- For Use With: Water
- Seal Material: Buna-N Rubber
Connect these valves to fire hydrants, fire pumps, and fire hoses to adjust the flow of water. Ideal for fighting fires, their internal gate allows unrestricted flow when fully open, unlike globe valves. However, you should only use these valves in emergencies when full flow is needed—they get damaged by throttling over time. They have a nonrising stem that stays in the same spot whether they’re open or closed.
Valves with a wheel handle take up less space than valves with a speed handle. The included hose cap protects them from dirt and debris. It’s connected to the valve with a chain, so you won’t lose it.
Valves with a speed handle can be turned with one hand, unlike valves with a wheel handle. Quickly connect the fittings to hydrants, pumps, and hoses with the easy-to-grip pin lugs on the sides. Tighten them with a hook-style spanner wrench. To prevent kinking when you’re connecting a hose, the fittings swivel until tightened. These valves are red so people know they’re fire valves.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.

Pipe Size | Fire Hose Trade Size | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Stem Type | Features | Specifications Met | Each | |
NPT Female Inlet × NH/NST Male Outlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
2 1/2 | 2 1/2 | 270 | 300 psi @ 72 ° F | 32° to 100° | 5" | Nonrising | Hose Cap and Chain | UL Listed, FM Approved | 0000000 | 0000000 |

Fire Hose Trade Size | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Stem Type | Each | |
NH/NST Female Inlet with Pin Lugs (Swivels Until Tightened) × NH/NST Male Outlet | |||||||
---|---|---|---|---|---|---|---|
2 1/2 | Not Rated | 175 psi @ 72 ° F | 32° to 100° | 4 13/16" | Nonrising | 0000000 | 0000000 |
NH/NST Female Inlet with Pin Lugs (Swivels Until Tightened) × NPSH Male Outlet | |||||||
2 1/2 | Not Rated | 175 psi @ 72 ° F | 32° to 100° | 4 13/16" | Nonrising | 0000000 | 000000 |