    207 Products

    Polypropylene Air-Powered Double Diaphragm Pumps for Chemicals

    Resistant to chemicals such as ammonia, detergents, and cleaning fluids, these pumps have a Santoprene diaphragm and polypropylene housing. They can be used to move thick sludges and slurries. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
    Threaded Bottom Intake and Threaded Top Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Polypropylene Air-Powered Double Diaphragm Pumps for Chemicals, Threaded Bottom Intake and Threaded Top Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    53.5215,00061/4 Female NPT1/4 Female NPT, 1/2 Male NPT1/4 Female NPT, 1/2 Male NPT6"7"8"4157K7200000003781K5900000003781K230000000
    14128510,000161/4 Female NPT1/2 Female NPT, 1 Male NPT1/2 Female NPT, 1 Male NPT7"10"12"4157K81000000003781K720000003781K94000000
    231913810,000201/4 Female NPT3/4 Female NPT, 1 1/2 Male NPT3/4 Female NPT, 1 1/2 Male NPT7"12"13"4157K833000000003781K720000003781K36000000
     
    Threaded Side Intake and Threaded Side Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Polypropylene Air-Powered Double Diaphragm Pumps for Chemicals, Threaded Side Intake and Threaded Side Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    77543,00061/4 Female NPT3/8 Female NPT3/8 Female NPT5"8"8"4157K131000000013465K65000000013465K660000000
     
    288 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    5.33.22.31.7Not Rated6.11/4 Female NPT1/4 Female NPT, 3/4 Male NPT1/4 Female NPT, 3/4 Male NPT7"5"7"2604K51000000———0———0
     
    Flanged Bottom Intake and Flanged Top Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Polypropylene Air-Powered Double Diaphragm Pumps for Chemicals, Flanged Bottom Intake and Flanged Top Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Flange
    Bolt
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake
    Size
    Discharge
    Size
    OD
    Thk.
    Pressure
    Class
    Circle
    Dia.
    Hole
    Dia.
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    10083513230,000503/4 Female NPT1 1/2
    1 1/2
    5"13/16"125
    3 7/8"5/8"13"23"29"4157K9110000000004157K2500000003781K810000000
    160125724340,000803/4 Female NPT2
    2
    6"5/8"125
    4 3/4"3/4"13"24"32"4157K121000000004157K250000004157K24000000
     

    Extended-Life Plastic Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Plastic Circulation Pumps for Chemicals.
    These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Repair Kits
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Pipe Size
    (Gender)
    Discharge Pipe
    Size (Gender)
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    120V AC/240V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    232010351/42.07 amp/4.14 amp1 (Female)1 (Female)14 3/8"5 1/8"7 7/8"3068N110000000003068N11200000003068N111000000
    262612351/33.24 amp/6.84 amp1 (Female)1 (Female)16 5/16"6 1/8"8 3/16"3068N12000000003068N1220000003068N12100000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    5757533025451/21.1 amp/2.2 amp1 1/2 (Female)1 1/2 (Female)18 3/8"8 7/8"11 5/16"3068N13000000003068N1320000003068N13100000
    9090847461497011.5 amp/3 amp1 1/2 (Female)1 1/2 (Female)18 7/8"6 5/16"10 1/8"3068N14000000003068N1420000003068N14100000
     
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    38363227214951/27.5 amp/3.7 amp1 (Female)3/4 (Male)15 1/2"9"8 1/4"3068N19000000003068N2220000003068N2210000
    535346403323260519.2 amp/4.6 amp to 6.3 amp1 1/2 (Female)1 (Male)17 13/16"9 1/8"8 3/16"3068N18000000003068N2320000003068N23100000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    3031262074151/31.2 amp to 1.3 amp/0.6 amp1 (Female)3/4 (Male)15 1/16"9 1/4"7 3/8"3068N21000000003068N2120000003068N2210000
    38363227214951/20.8 amp to 1.7 amp/1.7 amp1 (Female)3/4 (Male)15 1/16"9 1/8"7 3/16"3068N22000000003068N2220000003068N2210000
    535346403323260512.2 amp to 3.3 amp/1.1 amp1 1/2 (Female)1 (Male)16 9/16"9 1/8"7 3/8"3068N23000000003068N2320000003068N23100000
    8282828180716185524.8 amp to 4.9 amp/2.4 amp2 (Male)1 1/2 (Male)20 11/16"10 3/8"10"3068N24000000003068N242000000003068N24100000
    1201201201201121059295537.8 amp to 8 amp/3.9 amp2 (Male)1 1/2 (Male)24 3/8"11 1/2"10 1/2"3068N26000000003068N252000000003068N25100000
     

    Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style A.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style B.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style F.

    Style A

    Style B

    Style F

    Push the plunger to pump water, cleaners, and chemicals.
    Style A
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style A.
    Style A are for thin liquids with a maximum viscosity of 700 or 750 centipoise.
    Temp.
    Intake
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Each
    PVC Piston
    85 to 15700Not Rated1202 NPTDrum Connector1 1/2"22"Spout End2578K25000000
    2215 to 55700Not Rated1202 NPTDrum Connector1 1/2"39"Spout End2578K4500000
     
    Style B
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style B.
    Style B are for thin liquids with a maximum viscosity of 700 or 750 centipoise.
    Pumps
    Replacement
    Connectors
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    Pipe
    Size
    Each
    PVC Piston
    857504012070 mmDrum Connector1/2"13"Tube End7/16"5/8"22"PVC
    9918K1120000002 NPT9918K111000000
    85 to 15700Not Rated1202 NPTDrum Connector1 1/2"22"Tube End7/16"5/8"22"PVC
    2578K1500000———0
    2215 to 55700Not Rated1202 NPTDrum Connector1 1/2"39"Tube End7/16"5/8"36"PVC
    2578K3500000———0
     
    Style F
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style F.
    Style F are rated for liquids up to 2,500 centipoise.
    Pumps
    Connectors
    Replacement
    Connectors
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    Connection
    Each
    Pipe
    Size
    Each
    Viton® Fluoroelastomer Piston
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Polyethylene9918K7500000002 5/8"-5 Buttress9918K450000002 NPT9918K43000000
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Polyethylene9918K760000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
    28552,500351202"Drum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Polyethylene9918K120000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
    28552,500351202"Drum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Polyethylene9918K1150000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
     

    Water Aspirator Jet Pumps

    Image of Product. Front orientation. Jet Pumps. Water Aspirator Jet Pumps.
    Image of Attribute. Side1 orientation. CrossSection view. Contains Annotated. Jet Pumps. Water Aspirator Jet Pumps.
    Pick up chemical spills and remove liquids in vacuum filtering systems—these pumps create suction to draw up liquids and gases as water flows through them. They’re made of HDPE and polyethylene, so they won’t break down when exposed to highly corrosive chemicals and acids. The suction end has a barbed tube connector, which attaches to your vacuum tubing. The connector stays attached to your vacuum tubing and connects to the pump when you’re ready to use it again. These pumps also have an internal check valve to prevent backflow.
    Suction
    Intake
    Discharge
    Overall
    Flow Rate,
    gpm
    Max. Vacuum,
    in. Hg
    Min. Operating
    Pressure, psi
    Temp. Range,
    ° F
    For Tube ID
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Outlet
    Connection
    Gender
    Lg.
    Wd.
    Includes
    Each
    1.52711-140 to 2401/4", 5/16", 3/8"Male3/8
    NPT
    MaleWithout FittingsFemale3"3"4 1/2" Length of 3/8" OD Polyethylene Tubing3704N111000000

    Panel-Mount Fixed-Flow-Rate Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Panel-Mount Fixed-Flow-Rate Peristaltic Pumps for Chemicals.
    Install these pumps in a panel cutout. Often used in food and beverage, pharmaceutical, and lab applications, they dispense small amounts of liquid at a set rate. Pumps can be wired to a switch for manual operation, or a PLC for automated equipment. The removable pump head includes an intake tube that quickly connects to your line with barbed fittings (not included). To change lines, disconnect tubing and twist and pull the head off the motor. Then twist on a replacement head (sold separately). Pumps come in three colors for easy identification or to match your existing equipment. All are self-priming and create suction to draw liquid upward. Mount pumps up to 28 ft. above your liquid source. They can run dry.
    Discharge
    Overall
    Blue Housing
    Clear Housing
    Green Housing
    Flow Rate,
    ml/min
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake
    Connection
    Tube
    ID
    Tube
    OD
    Connection
    Wd.
    Ht.
    Dp.
    Each
    Each
    Each
    24V DC
     
    Hardwire
    552510,00032 to 1001/1501.5Barbed
    3/16"5/16"Barbed
    2 1/2"2 1/2"4 1/8"33341N18000000033341N21000000033341N230000000
    1602510,00032 to 1001/1501.5Barbed
    3/16"5/16"Barbed
    2 1/2"2 1/2"4 1/8"33341N1700000033341N1900000033341N22000000
     
    Replacement Pump Heads

    Compact Air-Powered Double Diaphragm Pumps

    Small enough to fit in the palm of your hand, these pumps transfer water, detergents, and chemicals. They have a chemical-resistant polypropylene housing. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps can run dry.
    Barbed Bottom Intake and Barbed Bottom Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. Compact Air-Powered Double Diaphragm Pumps, Barbed Bottom Intake and Barbed Bottom Discharge.
    Fluoroelastomer Diaphragm—Pumps with fluoroelastomer diaphragm are also suitable for use with fuel and oil.
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 1 ft.
    of Head
    @ 3 ft.
    of Head
    @ 4 ft.
    of Head
    @ 5 ft.
    of Head
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Tube
    Connection
    Intake Tube
    Connection
    Discharge Tube
    Connection
    Diaphragm
    Material
    Lg.
    Wd.
    Ht.
    Each
    15 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    553.72.91.87001.51/4" Barbed Male3/8" Male3/8" MaleSantoprene
    4 9/16"1 13/16"5 13/16"2753N130000000
    553.72.91.87001.751/4" Barbed Male1/2" Male1/2" MaleSantoprene
    4 9/16"1 13/16"5 13/16"2753N11000000
    553.72.91.87001.751/4" Barbed Male1/2" Male1/2" MaleFluoroelastomer
    4 9/16"1 13/16"5 13/16"2753N12000000
     

    High-Accuracy Metering Diaphragm Pumps for Chemicals

    Image of Product. Front orientation. Diaphragm Pumps.
    These diaphragm pumps meter a consistent amount of liquid within ±2% of the maximum flow. Often used to pump water-treatment chemicals, cleaning fluids, and electropolishing solutions, they have an adjustment dial that alters flow rate in 2% increments of the maximum flow. Pumps are self-priming and create suction to draw liquid upward. They can run dry but are not for use with solids.
    Repair Kits—Repair kits include a pump head assembly, a diaphragm, valves, and seals.
    Diaphragm Pumps
    Repair Kits
    Replacement
    Drain Valves
    Replacement
    Flow-Adjustment Valves
    For
    Tube
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    ID
    OD
    Lg.
    Wd.
    Ht.
    Features
    Each
    Each
    Each
    Each
    120V AC, Single Phase
     
    Plug In
    0.03 to 33001,00035 to 15011/6411/4"3/8"10 7/8"5 1/2"10 3/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K93000000082695K39000000082695K9400000082695K81000000
    0.05 to 52501,00035 to 15011/6411/4"3/8"10 7/8"5 1/2"10 3/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K4500000082695K3900000082695K940000082695K8100000
    0.12 to 122501,00035 to 15011/6411/4"3/8"11 1/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K5200000082695K3200000082695K820000082695K8100000
    0.22 to 221501,00035 to 15011/6411/4"3/8"11 1/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K5300000082695K3300000082695K820000082695K8100000
    0.24 to 241001,00035 to 15011/6411/4"3/8"10 3/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K5400000082695K3300000082695K820000082695K8100000
    0.42 to 421501,00035 to 15011/6411/4"3/8"11 3/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K550000000082695K33000000———0———0
    0.44 to 441001,00035 to 15011/6411/4"3/8"11 1/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K560000000082695K33000000———0———0
    0.94 to 941001,00035 to 15011/6413/8"1/2"11 3/4"5 1/2"11"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K570000000082695K3500000082695K710000082695K4100000
    1.2 to 1201001,00035 to 15011/6413/8"1/2"12"6 1/4"11 3/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K580000000082695K3600000082695K710000082695K4100000
    1.92 to 192501,00035 to 15011/6413/8"1/2"11 1/4"6 1/8"11 3/4"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K590000000082695K3700000082695K710000082695K4100000
    2.4 to 240351,00035 to 15011/6413/8"1/2"12"6 1/8"11 3/4"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K610000000082695K3700000082695K710000082695K4100000
    6 to 600301,00035 to 15011/6411/2"3/4"11 3/8"6 1/8"11"Backflow-Prevention Valve, Foot Valve/Strainer82695K620000000082695K3800000082695K42000000———0
     
    Replacements for Diaphragm Pumps

    PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals

    With all PTFE wetted parts, these pumps offer the best chemical resistance of all our air-powered double diaphragm pumps and can handle solvents and petroleum-based fluids that PVDF pumps can’t. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All can run dry.
    Threaded Side Intake and Threaded Side Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals, Threaded Side Intake and Threaded Side Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Overall
    Max. Flow
    Rate, gpm
    Max. Solids
    Dia.
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    6.70.08"9.31/8 Female NPT3/8 Female NPT3/8 Female NPT3 1/2"5 7/8"7 5/8"2925N20000000002666N2900000002666N220000000
    160.16"291/4 Female NPT1/2 Female NPT1/2 Female NPT6"9 3/16"8"2925N3000000002666N310000002666N2300000000
    390.24"461/4 Female NPT1 Female NPT1 Female NPT8"10 7/8"10 3/8"2925N4000000002666N320000002666N2400000000
     

    Siphon Drum Pumps

    Image of Product. Front orientation. Drum Pumps. Siphon Drum Pumps, Style A.
    Image of Product. Front orientation. Drum Pumps. Siphon Drum Pumps, Style B.

    Style A

    Style B

    Since these pumps use suction to draw liquid out of your container, they continue dispensing once you get them started. They're often used with coolant and water.
    5 gpm to 7 gpm Flow Rate—Adjust pumps with a 5-7 gpm flow rate for different dispensing applications.
    Temp.
    Intake
    Discharge
    Style
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Drum Pump
    Type
    Each
    A25150Not Rated14011/16"16"Tube End9/16"11/16"21"PolyethyleneSiphon9894K4400000
    A515 to 5588Not Rated1402 NPTDrum Connector7/8"34"Tube End13/16"1"48"PolyethyleneSiphon4270K2100000
    A715 to 5588Not Rated1402 NPTDrum Connector1"34"Tube End13/16"1"48"PolyethyleneSiphon4270K2200000
    B5 to 75650Not Rated1402 NPS, 70 mmDrum Connector1 1/2"16"Tube End1"1 1/4"60"PVC
    Siphon4270K2400000
    B5 to 75 to 6650Not Rated1402 NPSDrum Connector1 1/2"16"Tube End1"1 1/4"60"PVC
    Siphon4270K2500000
    B5 to 715650Not Rated1402 NPSDrum Connector1 1/2"24"Tube End1"1 1/4"60"PVC
    Siphon4270K2600000
     
    Connectors

    Miniature Metering Diaphragm Pumps for Chemicals

    Image of Product. Front orientation. Diaphragm Pumps. Miniature Metering Diaphragm Pumps for Chemicals.
    With a footprint that's only a few inches in any direction, these diaphragm pumps fit into compact systems to dispense small amounts of acids, cleaning fluids, and other chemicals. They're often used in sterilization, photochemical, and water treatment systems. Choose from pumps with either a 4-20mA or 1-5V DC input signal that controls the flow rate.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    External
    Intake
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Current,
    amp
    Signal,
    mA
    Voltage,
    V DC
    Gender
    For Tube
    ID
    Gender
    For Tube
    ID
    For Tube
    OD
    Lg.
    Wd.
    Ht.
    Each
    12V DC—With Thermal Overload Protection
     
    Hardwire
    1429630 to 1001.51 to 5Female1/8"Female1/8"1/4"4"2 1/2"3 5/8"2915N10000000
    1429630 to 1001.54 to 20Female1/8"Female1/8"1/4"4"2 1/2"3 5/8"2915N2000000
     
    24V DC—With Thermal Overload Protection
     
    Hardwire
    1429630 to 10011 to 5Female1/8"Female1/8"1/4"4"2 1/2"3 5/8"2915N3000000
    1429630 to 10014 to 20Female1/8"Female1/8"1/4"4"2 1/2"3 5/8"2915N4000000
     

    Foot-Operated Drum Pumps for Harsh Chemicals

    Image of Product. Front orientation. Drum Pumps. Foot-Operated Drum Pumps for Harsh Chemicals.
    Made of PVDF components, these pumps resist harsh chemicals such as hydrochloric acid and sulfuric acid. They have a foot pedal for hands-free operation. A telescoping intake tube works with containers of different heights.
    Temp.,
    ° F
    Intake
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube Lg.
    Discharge
    Location
    Spout
    Type
    Drum Pump
    Type
    Each
    530500351001 1/8" to 2 3/4"Drum Connector5/8"13" to 28"Spout EndRemovablePedal4482N110000000
     

    Compact Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Compact Drum Pumps for Water and Chemicals, Style B.

    Style B

    Designed to move low volumes of caustic liquids in confined areas, these pumps have a thin intake tube and a small handle. They are often used to pump cleaning fluids, acid-washing solutions, and bleach.
    Style B—Style B pumps have a flexible discharge spout.
    Temp.,
    ° F
    Intake
    Style
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max.
    Viscosity
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Spout
    Type
    Drum Pump
    Type
    Each
    B355Not Rated401502 NPTDrum Connector1 3/4"32"Spout EndFlexiblePlunger4277K330000000
     

    Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style A.
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style A

    Style B

    Alter the flow rate for versatile dispensing. These pumps do not include a drum connector.
    Tube-End Discharge
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style A.

    Style A

    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Electrical
    Style
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Connection
    No. of
    Blades
    Each
    Each
    120V AC—Single Phase—Plug In—With Thermal Overload Protection
    A0 to 18.5930300151201/41.532 mmWall Bracket1 1/4"27"3/4"1"60"Straight Blade242895K81000000042895K940000000
    A0 to 18.5955300151201/41.532 mmWall Bracket1 1/4"39"3/4"1"60"Straight Blade242895K8200000042895K95000000
     
    Pump Replacement Parts
    Pump Body
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style B

    Pumps
    Repair Kits
    Connectors
    Temp.
    Intake
    Discharge
    (Pump Body)
    Electrical
    Style
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Connection
    For Tube
    ID
    Connection
    No. of
    Blades
    Each
    Each
    Each
    120V AC—Single Phase—Plug In—With Thermal Overload Protection
    B0 to 3516551,500Not Rated13018.52"1 5/8"39"Barbed
    1"Straight Blade32850K350000000002850K7100000002850K62000000
    B0 to 3516551,500Not Rated13018.52"1 5/8"47"Barbed
    1"Straight Blade32850K36000000002850K710000002850K6200000
    B0 to 3516551,500Not Rated17518.52"1 5/8"39"Barbed
    1"Straight Blade32850K41000000002850K720000002850K6200000
     
    Pump Replacement Parts

    High-Flow Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. High-Flow Peristaltic Pumps for Chemicals.
    For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
    Intake
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    For Tube
    ID
    Connection
    For Tube
    ID
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    120V AC, Single Phase
     
    Plug In
    2,592201,00035 to 1601/43.11/2"Barbed
    1/2"Barbed
    10"5 1/2"10"10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61)4306K640000000
     
    Replacements for Peristaltic Pumps

    Remote-Adjustment High-Pressure Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Remote-Adjustment High-Pressure Peristaltic Pumps for Chemicals.
    Automatically control output from a distance using a variety of analog and digital signals, including 4-20mA and external pulse signals. Pumps can also be controlled manually, run on a schedule, or set to cycle on and off. View flow rate on the LED display. These pumps handle pressures four times higher than standard pumps. They meter a consistent amount of liquid within ±1% of the maximum flow. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake
    Connection
    Discharge
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    120V AC, Single Phase with With Thermal Overload Protection
     
    Plug In
    0.05 to 51001,50032 to 1003/320.6Compression
    Compression
    11"5 7/8"7 3/16"20 ft. of 1/4" OD Tubing2886N201000000000
    0.17 to 171001,50032 to 1003/320.6Compression
    Compression
    11"5 7/8"7 3/16"20 ft. of 1/4" OD Tubing2886N20200000000
    0.4 to 401001,50032 to 1003/320.6Compression
    Compression
    11"5 7/8"7 3/16"20 ft. of 1/4" OD Tubing2886N20300000000
    0.85 to 85251,50032 to 1003/320.6Compression
    Compression
    11"5 7/8"7 3/16"20 ft. of 1/4" OD Tubing2886N20400000000
    1.3 to 1251001,50032 to 100Not Rated0.6Compression
    Compression
    11"8 3/4"8 1/8"20 ft. of 3/8" OD Tubing2886N20500000000
     

    Drum Pumps for Harsh Chemicals

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Harsh Chemicals, Spout-End Discharge.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Harsh Chemicals, Nozzle Discharge.

    Spout-End

    Discharge

    Nozzle Discharge

    Made with PTFE components, these pumps stand up to aggressive chemicals our other drum pumps can't, such as hydrochloric acid, bleach, sodium hydroxide, and methyl ethyl ketone (MEK). A stopcock prevents fluid and vapor from leaking after use.
    Temp.,
    ° F
    Intake
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Each
    Spout-End Discharge
    916500351052"Drum Connector1 1/4"23 5/8"3024N1000000000
     
    Nozzle Discharge
    916500351052"Drum Connector1 1/4"23 5/8"3024N200000000
     

    High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    Designed to move 40 gallons of liquid per minute, these pumps quickly empty drum contents. They're often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions.
    Temp.,
    ° F
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—Plug In
    403035500351601/25.72 NPTDrum Connector2"27"Tube End1"1 5/16"60"PVC
    Straight Blade36800K12000000000
    405535500351601/25.72 NPTDrum Connector2"40"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1400000000
    405535500351601/25.72 NPTDrum Connector2"48"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1800000000
     
    Pump Replacement Parts

    High-Pressure Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. High-Pressure Peristaltic Pumps for Chemicals.
    These pumps can be used with pressures four times higher than standard pumps. An adjustment dial lets you alter flow rate in 2.5% increments of the maximum flow without the hassle of changing tubing. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
    Pumps
    Replacement
    Pump Heads
    Replacement
    Tubing
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake
    Connection
    Tube
    ID
    Tube
    OD
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    Each
    120V AC, Single Phase
     
    Plug In
    0.3 to 51001,50035 to 1251/301.7Compression
    3/16"1/4"Compression
    11"5"6"20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing9154K5100000009154K6100000009154K64000000
    0.8 to 171001,50035 to 1251/301.7Compression
    3/16"1/4"Compression
    11"5"6"20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing9154K520000009154K620000009154K6500000
    2 to 401001,50035 to 1251/301.7Compression
    3/16"1/4"Compression
    11"5"6"20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing9154K530000009154K630000009154K6600000
     

    Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Peristaltic Pumps for Chemicals.
    An adjustment screw lets you increase or decrease flow rate without the hassle of changing tubing. Often used in boiler feed systems and water treatment, these pumps are compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
    Pumps
    Replacement
    Pump Collars
    Replacement Pump
    Intake Tubes
    For
    Tube
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    ID
    OD
    Intake
    Connection
    Discharge
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    Each
    120V AC, Single Phase
     
    Plug In
    2 to 122520035 to 1001/640.33/16"3/8"Compression
    Compression
    8"7"6"9" Lg. of Tygon Tubing (Shore A70)43205K11000000043205K3300000043205K35000000
    3 to 202520035 to 1001/640.31/4"7/16"Compression
    Compression
    8"7"6"9" Lg. of Tygon Tubing (Shore A70)43205K1300000043205K340000043205K3600000
     
    Replacement Pump Heads

    Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
    Polypropylene Housing—Pumps with a polypropylene housing are often used with corrosives such as acid-washing solutions and cleaning and etching fluids. Their motors are rated IP44.
    PVDF Housing—Pumps with a PVDF housing are often used with aggressive chemicals such as 98% nitric acid, hydrochloric acid, and sulfuric acid. Their motors are rated IP54.
    47" Long Intake Tube—Pumps with a 47" intake tube can be used with large totes and tanks.
    Temp.
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Enclosure
    Rating
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—NEMA 5-15 Plug In
     
    Polypropylene Housing
    1515551,500Not Rated13017.52 NPT1 5/8"39"1"1 1/4"72"IP44
    Straight Blade37133T21000000000
    1515551,500Not Rated13017.52 NPT1 5/8"47"1"1 1/4"72"IP44
    Straight Blade37133T2200000000
     
    PVDF Housing
    1515551,500Not Rated17517.52 NPT1 5/8"39"1"1 1/4"72"IP54
    Straight Blade37133T2300000000
    1515551,500Not Rated17517.52 NPT1 5/8"47"1"1 1/4"72"IP54
    Straight Blade37133T2400000000
     

    Polypropylene Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. Polypropylene Long-Life Air-Powered Drum Pumps for Chemicals.
    The polypropylene housing provides good resistance to caustics such as ammonia, electropolishing solutions, and detergents and cleaning fluids. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/regulator to ensure efficiency and reduce wear on the pump.
    PTFE Diaphragm—Choose a pump with a PTFE diaphragm for superior resistance to a wider variety of concentrated chemicals than Santoprene.
    Repair Kits—Repair kits include components such as O-rings, valves, balls, and diaphragms.
    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    Santoprene Diaphragm
    13553,00030180100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT2534K1800000008281K460000000
    31558,00030180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT36"Pump BodyThreaded3/4 Female NPT8281K55000000008281K47000000
     
    PTFE Diaphragm
    13553,00040180100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT8281K520000008281K111000000
    28558,00040180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT36"Pump BodyThreaded3/4 Female NPT8281K57000000008281K48000000
     

    PVDF Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. PVDF Long-Life Air-Powered Drum Pumps for Chemicals.
    A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Repair Kits—Repair kits include O-rings, valves, and diaphragms.
    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    13553,00040210100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT2534K540000000008281K1110000000
     

    Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Contains Annotated. Drum Pumps. Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals.
    A filter/lubricator ensures efficiency and reduces wear on the pump. They have a chemically resistant seal for use with hydraulic oil and motor oil in addition to acidic and alkaline liquids such as ammonia and etching and cleaning solutions. Pumps have a nonsparking motor for use in applications where electricity is unavailable or dangerous.
    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube Lg.,
    ft.
    Tube
    Material
    Features
    Each
    Each
    16552,0003515080 to 100322 NPTDrum Connector1/4 Female NPT1 5/8"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler8243K310000000008243K620000000
    22553303516080 to 100322 NPTDrum Connector1/4 Female NPT2"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler4296K4100000000———0
    22553303516080 to 100322 NPTDrum Connector1/4 Female NPT2"48"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler4296K4800000000———0
     
    Couplings
    back to top