McMaster-Carr logo
    Filter by
    Power Source
    System of Measurement
    Batteries Included
    Electrical Connection Type
    Enclosure Rating
    Industrial Info Compare
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    18 Products

    Portable Multi-Gas Detectors

    Image of Product. Front orientation. Multi-Gas Detectors. Portable Multi-Gas Detectors.
    When these detectors sense high levels of combustible and toxic gases, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
    A calibration check must be performed on detectors before each use to verify that they are working properly. The check requires a regulator and cylinder (sold separately).
    Note: LEL is lower explosive limit.
    Detects (Measuring Range)
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Batteries
    Included
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL)
    Oxygen (0% to 30% Vol.)
    Carbon Monoxide (0 ppm to 1,999 ppm)
    Hydrogen Sulfide (0 ppm to 200 ppm)
    95 dBA @ 30 cm-40 to 140YesNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 0 Groups IIC, IIB, IIA
    AEx Da Ia IIC T4 Ga
    Ex Da Ia IIC T4 Ga
    IP68
    18995T42000000000
    Accessories for Multi-Gas Detectors

    Surface-Mount Multi-Gas Detectors

    Image of Product. Front orientation. Multi-Gas Detectors. Surface-Mount Multi-Gas Detectors.
    An audible alarm and warning light alert you to the presence of propane, methane, hydrogen, and carbon monoxide. These detectors have a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
    Cannot Be Sold To—Import regulations restrict sales to the listed areas.
    Detects (Trigger Point)
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dp.
    Voltage,
    V AC
    Cord Lg.,
    ft.
    Fasteners
    Included
    Mounting
    Hole Dia.
    Cannot Be
    Sold To
    Each
    Propane (420 ppm); Methane (5,000 ppm); Hydrogen (200 ppm); Carbon Monoxide (150 ppm)80 dB @ 10 ft.-20 to 1206 3/4"3 1/4"1 3/4"1206No3/16"Canada6631T180000000

    Gas Leak Detectors for Hard-to-Reach Areas

    Image of Product. Front orientation. Gas Leak Detectors. Gas Leak Detectors for Hard-to-Reach Areas.
    Identify a variety of small leaks quickly and access hard-to-reach areas with the flexible probe. An audible alert increases in intensity the closer you get to the leak. Intrinsically safe for Class I, Divisions I and 2, Groups A, B, C, and D hazardous locations.
    Cannot Be Sold Outside North America—Product regulations restrict sales to the listed areas.
    Detection Trigger Point, ppm
    Methane (Natural
    Gas)
    Propane
    Hydrogen
    Butane
    Acetone
    Methanol
    Ammonia
    Gasoline
    Chlorine
    Acetylene
    Ethane
    Ethylene
    Hydrogen
    Sulfide
    Batteries
    Included
    Container Type
    Cannot Be Sold To
    Each
    5555505020115055005YesPlastic Carrying CaseOutside North America1140T140000000
    Replacements for Gas Leak Detectors

    Early-Warning Surface-Mount Hydrogen Detectors

    Image of Product. Front orientation. Hydrogen Detectors. Early-Warning Surface-Mount Hydrogen Detectors.
    This detector triggers a “caution” alert when a small amount of hydrogen is detected and a second “danger” alert if levels continue to rise.
    1% Trigger Point—When hydrogen concentration reaches 1% by volume, a yellow warning light illuminates and the first relay closes to trigger a remote exhaust fan and/or alarm.
    2% Trigger Point—When hydrogen reaches 2%, a red warning light illuminates, an alarm sounds, and the second relay closes to activate another remote exhaust fan and/or alarm.
    Trigger
    Point
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dp.
    Electrical
    Connection
    Voltage, V AC
    Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    1%; 2%60 dB @ 10 ft.14 to 1047"4 3/4"2 1/2"Screw Terminal120, 240No3/16"71095K71000000000
    Accessories for Hydrogen Detectors

    Portable Multi-Gas Detectors with Probe

    Image of Product. Front orientation. Multi-Gas Detectors. Portable Multi-Gas Detectors with Probe.
    Use the probe on these detectors to test the air in a hazardous area before entering. Great for confined spaces. Detectors alert you with an audible alarm, warning light, and vibrating alarm in the presence of combustible and toxic gases. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
    A calibration check must be performed on these detectors before each use to verify that they are working properly. The check requires a regulator and cylinder (sold separately).
    Note: LEL is lower explosive limit.
    Detects (Measuring Range)
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Batteries
    Included
    Includes
    Tube Lg.,
    ft.
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL)
    Oxygen (0% to 30% Vol.)
    Carbon Monoxide (0 ppm to 1,999 ppm)
    Hydrogen Sulfide (0 ppm to 200 ppm)
    95 dBA @ 30 cm-40 to 140YesSampling Probe, Tubing Assembly, Battery25NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 0 Groups IIC, IIB, IIA
    AEx Da Ia IIC T4 Ga
    Ex Da Ia IIC T4 Ga
    IP68
    18995T44000000000
    Accessories and Replacements for Multi-Gas Detectors

    Surface-Mount Hydrogen Detectors

    Image of Product. Front orientation. Hydrogen Detectors. Surface-Mount Hydrogen Detectors.
    An audible alarm and warning light alert you to the presence of hydrogen. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
    Cannot Be Sold To—Import regulations restrict sales to the listed areas.
    Electrical
    Trigger
    Point, ppm
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dp.
    Connection
    No. of
    Blades
    Voltage,
    V AC
    Cord Lg.,
    ft.
    Fasteners
    Included
    Mounting
    Hole Dia.
    Cannot Be
    Sold To
    Each
    8,00080 dB @ 10 ft.-20 to 1206 3/4"3 1/4"1 3/4"Straight Blade21206No3/16"Canada6631T420000000

    Acoustic Imaging Gas Leak Detectors

    Image of Product. Front orientation. ZoomedIn view. Contains Inset, Border. Gas Leak Detectors. Acoustic Imaging Gas Leak Detectors.
    Locate leaks up to 10 times faster than traditional leak-detecting methods. These detectors use 124 microphones to determine the precise location and size of leaks in compressed air and specific gas systems. The screen displays a high-resolution acoustic image that’s overlaid on a digital live shot of your facility to help you visualize the leak. It also displays analytics related to the leak, such as the rate and the potential cost savings of patching your system. You can capture the on-screen view through photos and video to review later. With a built-in flashlight, they remain accurate even in low-light spaces. Light enough to carry with one hand, you can bring these detectors on the go. A 650 ft. range means you can use them from one end of your facility to another, or to detect in hard-to-reach systems.
    Connect the detector to your computer using Wi-Fi or the included USB cable to quickly transfer collected data.
    Max. Working
    Distance, ft.
    Freq. Measured
    Range, kHz
    Diag. Screen
    Size
    Directional
    Resolution Range
    Data
    Connection
    Wt.,
    lb.
    Housing
    Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Gas Leak Detected
    Batteries
    Included
    Container Type
    Includes
    Features
    Each
    6502 to 1305"1°-0.125°Wi-Fi, USB-A3.2Plastic0 to 120IP54
    Ammonia, Argon, Carbon Dioxide, Helium, Hydrogen, Methane, Compressed Gas LeakYesPlastic Carrying CaseBattery Charger, Charging Cord, Lanyard, USB DriveMemory Storage, LED Flashlight7203N120000000000
    Replacements for Gas Leak Detectors
    back to top