    Heater and Air Conditioner Duct Booster Fans

    Image of Product. Front orientation. Duct Fans. Heater and Air Conditioner Duct Booster Fans.
    Insert these fans directly into your ductwork. They give small heaters and air conditioners a boost to circulate air through ductwork. The crimped end construction makes inserting the fans easy.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Overall
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Each
    120V AC, Single Phase—Hardwire
    6"1240 ft³/min @ 0 in. H₂ONot Rated1,6007 1/4"255Galvanized SteelAluminum
    0000000000000
    8"1420 ft³/min @ 0 in. H₂ONot Rated1,6007 1/4"255Galvanized SteelAluminum
    000000000000
    10"1650 ft³/min @ 0 in. H₂ONot Rated1,6008"212Galvanized SteelAluminum
    0000000000000
    14"11,350 ft³/min @ 0 in. H₂ONot Rated1,6009 1/8"212Galvanized SteelAluminum
    0000000000000
     
    120V AC, Single Phase—Plug In
    4"165 ft³/min @ 0 in. H₂O47 dBA3,2006"140Galvanized SteelPolycarbonate
    000000000000
    12"1650 ft³/min @ 0 in. H₂O50 dBA1,3008"140Galvanized SteelPolycarbonate
    000000000000
     

    Direct-Drive Corrosion-Resistant Duct Fans

    Image of Product. Front orientation. Duct Fans. Direct-Drive Corrosion-Resistant Duct Fans.
    A galvanized steel housing offers good corrosion resistance. All of these direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, they install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Certification
    Each
    120V AC, Single Phase—Hardwire
    4"190 ft³/min @ 3/8 in. H₂O
    115 ft³/min @ 1/8 in. H₂O
    Not Rated3,0001/408 3/4"10 3/4"6 1/2"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    00000000000000
    5"1105 ft³/min @ 3/8 in. H₂O
    135 ft³/min @ 1/8 in. H₂O
    Not Rated3,0001/408 3/4"10 3/4"5 1/2"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    6"1240 ft³/min @ 3/8 in. H₂O
    280 ft³/min @ 1/8 in. H₂O
    Not Rated2,7001/1011 3/8"13 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    8"1360 ft³/min @ 3/8 in. H₂O
    425 ft³/min @ 1/8 in. H₂O
    Not Rated2,5501/613 3/8"15 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    8"1435 ft³/min @ 3/8 in. H₂O
    480 ft³/min @ 1/8 in. H₂O
    Not Rated2,9501/513 3/8"15 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    10"1540 ft³/min @ 3/8 in. H₂O
    570 ft³/min @ 1/8 in. H₂O
    Not Rated3,1001/413 3/8"15 3/8"5 7/8"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    12"1620 ft³/min @ 3/8 in. H₂O
    700 ft³/min @ 1/8 in. H₂O
    Not Rated2,6001/416"18"8 1/4"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
     
    120V AC, Single Phase—Plug In
    4"190 ft³/min @ 3/8 in. H₂O
    115 ft³/min @ 1/8 in. H₂O
    Not Rated3,0001/408 3/4"10 3/4"6 1/2"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    5"1105 ft³/min @ 3/8 in. H₂O
    135 ft³/min @ 1/8 in. H₂O
    Not Rated3,0001/408 3/4"10 3/4"5 1/2"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    8"1360 ft³/min @ 3/8 in. H₂O
    425 ft³/min @ 1/8 in. H₂O
    Not Rated2,5501/613 3/8"15 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    8"1435 ft³/min @ 3/8 in. H₂O
    480 ft³/min @ 1/8 in. H₂O
    Not Rated2,9501/513 3/8"15 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    10"1540 ft³/min @ 3/8 in. H₂O
    570 ft³/min @ 1/8 in. H₂O
    Not Rated3,1001/413 3/8"15 3/8"5 7/8"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
     

    Direct-Drive Duct Fans

    Image of Product. Front orientation. Duct Fans. Direct-Drive Duct Fans.
    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, these install inline in ductwork for use as an exhaust, supply, or booster fan. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing Material
    Blade
    Material
    Certification
    Hardware
    Included
    Hole
    Dia.
    Each
    120V AC, Single Phase—Hardwire
    4"195 ft³/min @ 3/8 in. H₂O
    135 ft³/min @ 1/8 in. H₂O
    Not Rated3,0501/409 1/2"9 1/2"9 5/8"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"000000000000000
    4"1143 ft³/min @ 3/8 in. H₂O
    168 ft³/min @ 1/8 in. H₂O
    Not Rated2,4501/910"10 1/2"10 9/16"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"000000000000000
    5"1105 ft³/min @ 3/8 in. H₂O
    150 ft³/min @ 1/8 in. H₂O
    Not Rated3,0501/409 1/2"9 1/2"7 7/8"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"00000000000000
    6"1201 ft³/min @ 3/8 in. H₂O
    255 ft³/min @ 1/8 in. H₂O
    Not Rated2,4501/1211 5/8"12 1/8"9 7/32"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"000000000000000
    6"1250 ft³/min @ 3/8 in. H₂O
    308 ft³/min @ 1/8 in. H₂O
    Not Rated2,1501/611 5/8"12 1/8"9 7/32"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"000000000000000
    6"1250 ft³/min @ 3/8 in. H₂O
    300 ft³/min @ 1/8 in. H₂O
    Not Rated2,4501/1011 3/4"11 3/4"9 5/8"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"00000000000000
     

    DC Heater and Air Conditioner Duct Booster Fans

    Image of Product. Front orientation. Duct Fans. DC Heater and Air Conditioner Duct Booster Fans.
    Often used in vehicles, these fans operate on DC power. Insert them directly into your ductwork. They give small heaters and air conditioners a boost to circulate air through ductwork. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Ht.
    Wd.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    12V DC—Hardwire
    3"1130 ft³/min @ 0 in. H₂O65 dBA @ 15 ft.3 3/16"5"5 1/4"200PolypropylenePolypropylene
    No3/16"00000000000000
    4"1230 ft³/min @ 0 in. H₂O69 dBA @ 15 ft.4 3/16"6"5 1/4"200PolypropylenePolypropylene
    No3/16"0000000000000
     

    High-Output Direct-Drive Duct Fans

    Image of Product. Front orientation. Duct Fans. High-Output Direct-Drive Duct Fans.
    Produce three times the airflow as standard direct-drive duct fans. All of these direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, they install inline in ductwork for use as an exhaust, supply, or booster fan. All have a TEFC (totally enclosed fan cooled) motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Bolt Circle
    Dia.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Each
    120V AC, 230V AC, Single Phase—Hardwire
    12"11,900 ft³/min @ 3/8 in. H₂O
    2,000 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.3,4501/214 1/16"14 1/16"20"13 1/8"100SteelAluminum
    No3/8"
    7/16"80000000000000000
    15"12,100 ft³/min @ 3/8 in. H₂O
    2,700 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,7501/217 1/16"17 1/16"20"16 1/8"100SteelAluminum
    No3/8"
    7/16"8000000000000000
    18"13,900 ft³/min @ 3/8 in. H₂O
    4,500 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,7503/420 1/16"20 1/16"20"19 1/8"100SteelAluminum
    No3/8"
    7/16"8000000000000000
    24"14,900 ft³/min @ 3/8 in. H₂O
    5,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,7503/426 11/16"26 11/16"21"25 13/16"100SteelAluminum
    No3/8"
    7/16"8000000000000000
     
    230V AC, 460V AC, Three Phase—Hardwire
    12"11,900 ft³/min @ 3/8 in. H₂O
    2,000 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.3,4501/214 1/16"14 1/16"20"13 1/8"100SteelAluminum
    No3/8"
    7/16"8000000000000000
    15"12,100 ft³/min @ 3/8 in. H₂O
    2,700 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,7501/217 1/16"17 1/16"20"16 1/8"100SteelAluminum
    No3/8"
    7/16"8000000000000000
    18"13,900 ft³/min @ 3/8 in. H₂O
    4,500 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,7503/420 1/16"20 1/16"20"19 1/8"100SteelAluminum
    No3/8"
    7/16"8000000000000000
    24"14,900 ft³/min @ 3/8 in. H₂O
    5,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,7503/426 11/16"26 11/16"21"25 13/16"100SteelAluminum
    No3/8"
    7/16"8000000000000000
     

    Belt-Drive Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Duct Fans.
    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Also known as axial duct fans, these install inline in ductwork for use as an exhaust, supply, or booster fan. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC, 230V AC, Single Phase—Hardwire
    12"11,400 ft³/min @ 3/8 in. H₂O
    1,600 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.3,4501/214 1/16"23 7/16"12"175SteelAluminum
    No7/16"0000000000000000
    15"12,800 ft³/min @ 3/8 in. H₂O
    3,200 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,2753/417 1/16"26 15/16"12"175SteelAluminum
    No7/16"000000000000000
    18"12,500 ft³/min @ 3/8 in. H₂O
    3,400 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,6001/220 1/16"30 3/16"12"175SteelAluminum
    No7/16"000000000000000
     
    230V AC, 460V AC, Three Phase—Hardwire
    18"14,400 ft³/min @ 3/8 in. H₂O
    4,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,150120 1/16"30 3/16"12"175SteelAluminum
    No7/16"000000000000000
    24"17,000 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.1,8001 1/226 11/16"36 11/16"12"175SteelAluminum
    No7/16"000000000000000
    36"113,300 ft³/min @ 3/8 in. H₂O
    15,200 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,000239 1/4"49 1/4"16"175SteelAluminum
    No7/16"000000000000000
     

    Direct-Drive Hazardous Location Duct Fans

    Image of Product. Front orientation. Duct Fans. Direct-Drive Hazardous Location Duct Fans.
    These fans have an explosion-proof motor that is UL listed for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups F and G hazardous environments. All are direct-drive fans that have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, they install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a TEFC (totally enclosed fan cooled) motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Certification
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC, 230V AC, Single Phase—Hardwire
     
    IP44 Enclosure Rating
    12"11,900 ft³/min @ 3/8 in. H₂O
    2,000 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.3,4501/214 1/16"14 1/16"20"100SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"0000000000000000
    15"12,100 ft³/min @ 3/8 in. H₂O
    2,700 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,7501/217 1/16"17 1/16"20"100SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
    18"13,900 ft³/min @ 3/8 in. H₂O
    4,500 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,7503/420 1/16"20 1/16"20"100SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
    24"14,900 ft³/min @ 3/8 in. H₂O
    5,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,7503/426 11/16"26 11/16"21"100SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
     
    230V AC, 460V AC, Three Phase—Hardwire
     
    IP44 Enclosure Rating
    12"11,900 ft³/min @ 3/8 in. H₂O
    2,000 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.3,4501/214 1/16"14 1/16"20"100SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
    15"12,100 ft³/min @ 3/8 in. H₂O
    2,700 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,7501/217 1/16"17 1/16"20"100SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
    18"13,900 ft³/min @ 3/8 in. H₂O
    4,500 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,7503/420 1/16"20 1/16"20"100SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
    24"14,900 ft³/min @ 3/8 in. H₂O
    5,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,7503/426 11/16"26 11/16"21"100SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
     

    Belt-Drive Hazardous Location Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Hazardous Location Duct Fans.
    These fans have an explosion-proof motor that is rated for hazardous environments. All are belt-drive fans that are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. UL and CSA standards apply to the motor.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    IP44 Enclosure Rating—Fans rated IP44 have a motor enclosure that's rated for protection in damp environments.
    IP56 Enclosure Rating— Fans rated IP56 have a motor enclosure that’s rated for protection in damp, dusty, and washdown environments.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Certification
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC, 230V AC, Single Phase—Hardwire
     
    IP44 Enclosure Rating
    12"11,400 ft³/min @ 3/8 in. H₂O
    1,600 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.3,0251/214 1/16"23 7/16"12"175SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"0000000000000000
    15"12,800 ft³/min @ 3/8 in. H₂O
    3,200 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,2753/417 1/16"26 15/16"12"175SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
    18"12,500 ft³/min @ 3/8 in. H₂O
    3,400 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,6001/220 1/16"30 3/16"12"175SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
     
    230V AC, 460V AC, Three Phase—Hardwire
     
    IP44 Enclosure Rating
    18"14,400 ft³/min @ 3/8 in. H₂O
    4,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,150120 1/16"30 3/16"12"175SteelAluminum
    UL Recognized Component, CSA Energy Verified, CSA Certified
    No7/16"000000000000000
    36"113,300 ft³/min @ 3/8 in. H₂O
    15,200 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,000239 1/4"49 1/4"16"175SteelAluminum
    UL Listed, UL Recognized Component, CSA Energy Verified, CSA Certified
    No7/16"000000000000000
     
    IP56 Enclosure Rating
    24"17,000 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.1,8001 1/226 11/16"36 11/16"12"175SteelAluminum
    UL Listed
    No7/16"000000000000000
     

    Belt-Drive Corrosion-Resistant Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Corrosion-Resistant Duct Fans.
    A 304 stainless steel housing offers good corrosion resistance. All of these belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing Material
    Blade Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC, 460V AC, Three Phase—Hardwire
    12"11,600 ft³/min @ 3/8 in. H₂O
    1,800 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.3,0503/414 1/16"25 5/8"20"200304 Stainless SteelStainless Steel
    No7/16"0000000000000000
    18"14,600 ft³/min @ 3/8 in. H₂O
    4,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,3501 1/220 1/16"32 11/16"20"200304 Stainless SteelStainless Steel
    No7/16"000000000000000
    24"17,200 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,700226 11/16"38 3/4"21"200304 Stainless SteelStainless Steel
    No7/16"000000000000000
     