McMaster-Carr logo
    Filter by
    System of Measurement
    Projection
    Container Type
    DFARS Specialty Metals
    Door Height
    Maximum Temperature
    Mounting Location
    Sound Blocked
    Minimum Temperature
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Container Net Weight
    Side Pad Height
    Reaches Full Strength
    Reusable
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    23 Products

    Sound Barrier Partitions

    Image of Product. Two Partitions Shown. Front orientation. Sound Barrier Partitions.

    Two Partitions Shown

    Set up these free-standing partitions to reflect sound and block noise from traveling to other parts of your facility. A vinyl barrier is sandwiched between two vinyl-coated fiberglass absorbers. Partitions have five grommets across the top for attaching to the frame; hook-and-loop fasteners on the sides join multiple partitions together.
    Sound Blocked
    Thk.
    Wd.
    Lg.,
    ft.
    Material
    Temp. Range,
    ° F
    Features
    Each
    25 dBA to 27 dBA2"54"8 1/2Vinyl-Coated Fiberglass-20 to 180Five 5/8" Grommets on Top Edge, Frame, Hook and Loop Fasteners on Sides, Moisture Barrier53495T340000000

    Gap-Filling Spray Foam Insulation

    Seal and insulate cracks, gaps, and other hollow spaces with this insulation.
    Cleaners for dispensing guns (sold separately) extend the life of dispensing guns.
    Nonreusable
    Image of Product. Front orientation. Spray Foam Insulation. Gap-Filling Spray Foam Insulation, Nonreusable.
    Image of Product. Front orientation. Spray Foam Insulation Guns.

    Dispensing Guns

    1.2 cu. ft. Approximate Coverage—Insulation that covers 1.2 cu. ft. is best for touch-up and repair jobs.
    12 cu. ft. Approximate Coverage—Insulation that covers 12 cu. ft. comes out in a smooth line, so they're useful for filling and sealing gaps to prevent airflow.
    12.3 cu. ft. Approximate Coverage—Insulation that covers 12.3 cu. ft. sprays farther and more thoroughly than other foam insulation. Use them to fill cavities, channels, framing, and hollow tubing.
    Spray Foam Insulation
    Dispensing Guns
    Cleaners for
    Dispensing Guns
    Container
    Net Wt.,
    lb.
    Type
    Approx. Coverage
    Volume, cu. ft.
    Begins to
    Harden, min.
    Reaches Full
    Strength, hr.
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Color
    Temp. Range,
    ° F
    Includes
    Flammability Rating
    Each
    Each
    Each
    For Walls and Ceilings
    4Can1.2510.16 BTU/hr @ 75° F2.11Beige-200 to 240Two Cans of Foam with Two Cone Spray Nozzles9325K64000000———0———0
    16Cylinder12.35240.2 BTU/hr @ 75° F1.3Beige-200 to 240One Cylinder with Two Trigger-Style WandsASTM E84 5/20 for Flame and Smoke
    9325K11000000———0———0
    30Cylinder122240.16 BTU/hr @ 75° F2.5Beige-200 to 240Two Cylinders with a Trigger-Style Gun and Ten Cone Spray NozzlesASTM E84 0/45 for Flame and Smoke
    4342N110000008551K140000007738A34000000
     
    Reusable
    Image of Product. Front orientation. Spray Foam Insulation. Gap-Filling Spray Foam Insulation, Reusable.
    5 cu. ft. Approximate Coverage and 9.6 cu. ft. Approximate Coverage—Insulation that covers 5 or 9.6 cu. ft is good for applications that require firmness, such as roofing and where there’s foot traffic. It comes out smooth, so you won’t need to add extra layers or smooth it yourself. The included snap-tip nozzles spray in either a fan or cone pattern.
    Container
    Net Wt.,
    lb.
    Type
    Approx. Coverage
    Volume, cu. ft.
    Begins to
    Harden, min.
    Reaches Full
    Strength, hr.
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Color
    Temp. Range,
    ° F
    Includes
    Each
    For Walls and Ceilings
    15Cylinder5510.16 BTU/hr @ 75° F3.1Beige-200 to 200Two Cylinders with a Trigger-Style Gun and Ten Snap-Tip Nozzles9325K580000000
    30Cylinder9.6510.16 BTU/hr @ 75° F3.1Beige-200 to 200Two Cylinders with a Trigger-Style Gun and Ten Snap-Tip Nozzles9325K59000000
     
    Replacement Nozzles

    Contact-Sensing Switch Padding

    Image of ProductInUse. Padding Installed on a Positioning Slide. Front orientation. Switch Padding. Contact-Sensing Switch Padding.
    Image of ProductInUse. Padding Installed on a Vacuum Lifter. Front orientation. Switch Padding. Contact-Sensing Switch Padding.

    Padding Installed on a

    Positioning Slide

    Padding Installed on a Vacuum

    Lifter

    To help prevent injuries, this padding triggers a safety stop when it’s touched. Built-in pressure sensors signal your equipment to stop moving within nine milliseconds. Install this padding anywhere contact is a concern—it’s often used on carriages, guide rails, and autonomous vehicles.
    For a complete system, you’ll need a control box and enough pads to surround your equipment. All components meet international safety design standards.
    Controllers
    Image of Product. Front orientation. Switch Padding. Contact-Sensing Switch Padding, Controllers.
    Connect control boxes to your safety circuit to send a stop signal if any pad detects contact. They have duplicate outputs—also called redundant signals—so they’ll stop your equipment even if one output fails. Once you’ve cleared a collision, press a button to reset the safety system.
    These boxes are already programmed to control up to 15 pads, so there’s no complicated configuration software or programming needed. To install, use the included cords to connect to a pad and to terminals on your PLC, relay, or controller.
    Input
    Voltage,
    V DC
    Electrical
    Connection
    Lg.,
    mm
    Wd.,
    mm
    Ht.,
    mm
    Enclosure
    Rating
    Housing
    Material
    Includes
    Certification
    Each
    24Terminal Block976437.8IP50
    PlasticOne 5 m Lg. Controller-to-Padding Cord, One 5 m Lg. Control Box-to-Safety Circuit CordTUV Rheinland Certified, C-TUV Rheinland Certified, CE Marked
    7000N1060000000

    Flame-Retardant Gap-Filling Spray Foam Insulation

    This two-part expanding foam insulation meets ASTM standards for flame and smoke and covers large areas. It can be cut after 5 minutes and reaches full strength in an hour. To use outdoors, paint or cover for UV resistance. The included snap-tip nozzles spray in either a fan or cone pattern.
    Reusable
    Image of Product. Front orientation. Spray Foam Insulation. Flame-Retardant Gap-Filling Spray Foam Insulation.
    Container
    Net Wt.,
    lb.
    Type
    Approx. Coverage
    Volume, cu. ft.
    Begins to
    Harden, min.
    Reaches Full
    Strength, hr.
    Heat Flow Rate
    @ Temp.
    Density,
    lb/ft³
    Color
    Temp. Range,
    ° F
    Includes
    Flammability Rating
    Each
    For Walls and Ceilings
    15Cylinder9.7510.154 BTU/hr @ 75° F1.75Beige-200 to 240Two Cylinders with a Trigger-Style Gun and Eight Snap-Tip NozzlesASTM E84 10/350 for Flame and Smoke
    9325K7220000000
    30Cylinder17510.154 BTU/hr @ 75° F1.75Beige-200 to 240Two Cylinders with a Trigger-Style Gun and Eight Snap-Tip NozzlesASTM E84 10/350 for Flame and Smoke
    9325K721000000
     
    Replacement Nozzles

    Insulating Window Film

    Image of ProductInUse. Front orientation. Window Film. Insulating Window Film.
    Once heated, this film creates a tight seal around windows to prevent drafts.
    Wd.
    Lg.,
    ft.
    Clarity
    Material
    Reusable
    For Use
    Outdoors
    Includes
    Mount Type
    Mounting
    Location
    Each
    62"7ClearPolyethyleneNoNoTape with Adhesive on Both SidesHeat ShrinkWindow Frame1014A5200000
    62"17ClearPolyethyleneNoNoTape with Adhesive on Both SidesHeat ShrinkWindow Frame1014A5400000
    84"9ClearPolyethyleneNoNoTape with Adhesive on Both SidesHeat ShrinkWindow Frame1014A5600000
    84"19ClearPolyethyleneNoNoTape with Adhesive on Both SidesHeat ShrinkWindow Frame1014A5800000
    Mounting Tape

    Dock Door Seals

    Image of ProductInUse. Front orientation. Dock Door Seals. Dock Door Seals.
    Close the gap between your dock door and a trailer to keep heated or cooled air in and dust out while loading or unloading. Choose a seal that projects a maximum of 5" beyond your dock bumper.
    20" Projection—If your dock has an edge-of-dock leveler, order the seal with a 20" projection.
    For
    Door, ft.
    Top Pads
    Side Pads
    10" Projection
    12" Projection
    14" Projection
    16" Projection
    20" Projection
    Ht.
    Wd.
    Material
    Color
    Backing
    Material
    No.
    Included
    Ht.,
    ft.
    Wd.,
    ft.
    No.
    Included
    Ht.,
    ft.
    Wd.,
    ft.
    Mounting Fasteners
    Included
    Each
    Each
    Each
    Each
    Each
    88Vinyl-Coated FoamBlackWood1110281Yes21735T1100000000021735T2200000000021735T2300000000021735T2400000000021735T53000000000
    98Vinyl-Coated FoamBlackWood1110291Yes21735T3100000000———0———0———0———0
    back to top